These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
148 related articles for article (PubMed ID: 37904858)
1. Modelling and correcting the impact of RF pulses for continuous monitoring of hyperpolarized NMR. von Witte G; Ernst M; Kozerke S Magn Reson (Gott); 2023; 4(2):175-186. PubMed ID: 37904858 [TBL] [Abstract][Full Text] [Related]
2. A method for measuring the decay time of hyperpolarized 129Xe magnetization in rat brain without estimation of RF flip angles. Wakai A; Nakamura K; Kershaw J; Kondoh Y; Wright D; Kanno I Magn Reson Med Sci; 2005; 4(1):19-25. PubMed ID: 16127250 [TBL] [Abstract][Full Text] [Related]
3. Optimal (2)H rf Pulses and (2)H-(13)C Cross-Polarization Methods for Solid-State (2)H MAS NMR of Perdeuterated Proteins. Wei D; Akbey Ü; Paaske B; Oschkinat H; Reif B; Bjerring M; Nielsen NC J Phys Chem Lett; 2011 Jun; 2(11):1289-94. PubMed ID: 26295423 [TBL] [Abstract][Full Text] [Related]
4. The measurement of relaxation rates of degenerate Tugarinov V; Clore GM J Magn Reson; 2021 Sep; 330():107034. PubMed ID: 34329805 [TBL] [Abstract][Full Text] [Related]
5. Multiband spectral-spatial RF excitation for hyperpolarized [2- Marco-Rius I; Cao P; von Morze C; Merritt M; Moreno KX; Chang GY; Ohliger MA; Pearce D; Kurhanewicz J; Larson PE; Vigneron DB Magn Reson Med; 2017 Apr; 77(4):1419-1428. PubMed ID: 27017966 [TBL] [Abstract][Full Text] [Related]
6. Composite pulses for RF phase encoded MRI: A simulation study. Salajeghe S; Babyn P; Sarty GE Magn Reson Imaging; 2017 Feb; 36():40-48. PubMed ID: 27743871 [TBL] [Abstract][Full Text] [Related]
10. Constant-variable flip angles for hyperpolarized media MRI. Deng H; Zhong J; Ruan W; Chen X; Sun X; Ye C; Liu M; Zhou X J Magn Reson; 2016 Feb; 263():92-100. PubMed ID: 26774646 [TBL] [Abstract][Full Text] [Related]
12. Design of universal parallel-transmit refocusing k Gras V; Mauconduit F; Vignaud A; Amadon A; Le Bihan D; Stöcker T; Boulant N Magn Reson Med; 2018 Jul; 80(1):53-65. PubMed ID: 29193250 [TBL] [Abstract][Full Text] [Related]
13. A simple correction for B1 field errors in magnetization transfer ratio measurements. Samson RS; Wheeler-Kingshott CA; Symms MR; Tozer DJ; Tofts PS Magn Reson Imaging; 2006 Apr; 24(3):255-63. PubMed ID: 16563954 [TBL] [Abstract][Full Text] [Related]
14. Rapid assessment of longitudinal relaxation time in materials and tissues with extremely fast signal decay using UTE sequences and the variable flip angle method. Springer F; Steidle G; Martirosian P; Syha R; Claussen CD; Schick F Invest Radiol; 2011 Oct; 46(10):610-7. PubMed ID: 21577126 [TBL] [Abstract][Full Text] [Related]
15. Flip angle effects in STEAM and PRESS-optimized versus sinc RF pulses. Ryner LN; Ke Y; Thomas MA J Magn Reson; 1998 Mar; 131(1):118-25. PubMed ID: 9533913 [TBL] [Abstract][Full Text] [Related]
16. Broadband RF-amplitude-dependent flip angle pulses with linear phase slope. Koos MRM; Feyrer H; Luy B Magn Reson Chem; 2017 Sep; 55(9):797-803. PubMed ID: 28321918 [TBL] [Abstract][Full Text] [Related]
17. Broadband excitation in solid-state NMR using interleaved DANTE pulse trains with N pulses per rotor period. Lu X; Trébosc J; Lafon O; Carnevale D; Ulzega S; Bodenhausen G; Amoureux JP J Magn Reson; 2013 Nov; 236():105-16. PubMed ID: 24095842 [TBL] [Abstract][Full Text] [Related]
18. Rapid 2D variable flip angle method for accurate and precise T Lena B; Bos C; Ferrer CJ; Moonen CTW; Viergever MA; Bartels LW NMR Biomed; 2021 Aug; 34(8):e4542. PubMed ID: 34031938 [TBL] [Abstract][Full Text] [Related]