These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 37913670)

  • 1. Decision threshold as a gauge of the measurement quality in gamma-ray spectrometric measurements.
    Cindro DG; Korun M; Petrovič T; Vodenik B; Zorko B
    Appl Radiat Isot; 2024 Jan; 203():111088. PubMed ID: 37913670
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calculation of the detection limits with the least-squares method in gamma-ray spectrometry: A simple procedure.
    Petrovič T; Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2024 Mar; 205():111182. PubMed ID: 38232489
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calculation of the decision thresholds in gamma-ray spectrometry.
    Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2014 Dec; 94():221-229. PubMed ID: 25233528
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of the measurement threshold in gamma-ray spectrometry.
    Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2017 Mar; 121():126-130. PubMed ID: 28063382
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calculation of decision thresholds according to the standard ISO 11929-3 in case of presence of the peaked background.
    Korun M; Petrovič T; Vodenik B; Zorko B
    Appl Radiat Isot; 2023 Mar; 193():110682. PubMed ID: 36682310
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An alternative approach to the decision threshold.
    Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2018 Apr; 134():56-58. PubMed ID: 28843734
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Calculation of the detection limits for radionuclides identified in gamma-ray spectra based on post-processing peak analysis results.
    Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2018 Mar; 133():22-30. PubMed ID: 29274523
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calculation of the decision threshold in gamma-ray spectrometry using sum peaks.
    Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2016 Mar; 109():522-525. PubMed ID: 26625726
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of gamma-ray spectrometric results near the decision threshold.
    Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2013 Mar; 73():1-8. PubMed ID: 23238429
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calculation of the correlation coefficients between the numbers of counts (peak areas and backgrounds) obtained from gamma-ray spectra.
    Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2016 Dec; 118():1-6. PubMed ID: 27571962
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determining the probability of locating peaks using computerized peak-location methods in gamma-ray spectra as a function of the relative peak-area uncertainty.
    Ali Santoro MC; Anagnostakis MJ; Boshkova T; Camacho A; Iljadica MCF; Collins SM; Perez RD; Delgado JU; Đurašavić M; Duch MA; Elvira VH; Gomes RS; Gudelis A; Gurau D; Hurtado Bermudez S; Idoeta R; Jevremović A; Kandić A; Korun M; Karfopolous K; Laubenstein M; Long S; Margineanu RM; Mitsios I; Mulas D; Nikolić JK; Pantelica A; Medina VP; Pibida L; Potiriadis C; Silva RL; Siri S; Šešlak B; Verheyen L; Vodenik B; Vukanac I; Wiedner H; Zorko B
    Appl Radiat Isot; 2020 Jan; 155():108920. PubMed ID: 31622844
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Enhancements on the decision threshold algorithm of the net count calculation method.
    Liu B; Kalinowski M; Muramoto T
    Appl Radiat Isot; 2020 May; 159():109084. PubMed ID: 32250759
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Uncertainty calculations for the measurement of in vivo bone lead by x-ray fluorescence.
    O'Meara JM; Fleming DE
    Phys Med Biol; 2009 Apr; 54(8):2449-61. PubMed ID: 19336842
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reliability of the peak-analysis results in gamma-ray spectrometry for high relative peak-area uncertainties.
    Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2015 Nov; 105():60-65. PubMed ID: 26248084
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New method to determine the decision threshold for low-level radioactivity measurements.
    Lee KB; Lee JM; Park TS; Oh PJ; Lee SH; Han JB
    Appl Radiat Isot; 2013 Nov; 81():7-9. PubMed ID: 23578909
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement function for the activities of multi-gamma-ray emitters in gamma-ray spectrometric measurements.
    Korun M; Vodenik B; Zorko B
    Appl Radiat Isot; 2016 Mar; 109():518-521. PubMed ID: 26671790
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pricing Treatments Cost-Effectively when They Have Multiple Indications: Not Just a Simple Threshold Analysis.
    Goldhaber-Fiebert JD; Cipriano LE
    Med Decis Making; 2023; 43(7-8):914-929. PubMed ID: 37698120
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of gamma-ray spectra with spectral unmixing - Part I: Determination of the characteristic limits (decision threshold and statistical uncertainty) for measurements of environmental aerosol filters.
    Xu J; Bobin J; de Vismes Ott A; Bobin C; Malfrait P
    Appl Radiat Isot; 2022 Apr; 182():110109. PubMed ID: 35152161
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Empirical determination of the correlation coefficient between the number of counts in a peak in a gamma-ray spectrum and the number of counts in the continuum where the peak is superimposed.
    Korun M; Petrovič T; Vodenik B; Zorko B
    Appl Radiat Isot; 2020 Apr; 158():109063. PubMed ID: 32174377
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Uncertainty evaluation in gamma spectrometric measurements: Uncertainty propagation versus Monte Carlo simulation.
    Ramebäck H; Lindgren P
    Appl Radiat Isot; 2018 Dec; 142():71-76. PubMed ID: 30273761
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.