These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Comparison of two computed tomography perfusion post-processing software to assess infarct volume in patients with acute ischemic stroke. Liu J; Wang J; Wu J; Gu S; Yao Y; Li J; Li Y; Ren H; Luo T Front Neurosci; 2023; 17():1151823. PubMed ID: 37179549 [TBL] [Abstract][Full Text] [Related]
6. Pretreatment brain CT perfusion thresholds for predicting final infarct volume in distal medium vessel occlusions. Yedavalli V; Hamam O; Mohseni A; Chen K; Wang R; Heo HY; Heit J; Marsh EB; Llinas R; Urrutia V; Xu R; Gonzalez F; Albers G; Hillis A; Nael K J Neuroimaging; 2023; 33(6):968-975. PubMed ID: 37357133 [TBL] [Abstract][Full Text] [Related]
7. Automated estimation of ischemic core volume on noncontrast-enhanced CT via machine learning. Chen IE; Tsui B; Zhang H; Qiao JX; Hsu W; Nour M; Salamon N; Ledbetter L; Polson J; Arnold C; BahrHossieni M; Jahan R; Duckwiler G; Saver J; Liebeskind D; Nael K Interv Neuroradiol; 2022 Dec; ():15910199221145487. PubMed ID: 36572984 [TBL] [Abstract][Full Text] [Related]
8. Correlation of Alberta Stroke Program Early Computed Tomography Score With Computed Tomography Perfusion Core in Large Vessel Occlusion in Delayed Time Windows. Voleti S; Vidovich J; Corcoran B; Zhang B; Khandwala V; Mistry EA; Khatri P; Tomsick T; Vagal A Stroke; 2021 Jan; 52(2):498-504. PubMed ID: 33406866 [TBL] [Abstract][Full Text] [Related]
9. Comparison of automated infarct core volume measures between non-contrast computed tomography and perfusion imaging in acute stroke code patients evaluated for potential endovascular treatment. Suomalainen OP; Elseoud AA; Martinez-Majander N; Tiainen M; Forss N; Curtze S J Neurol Sci; 2021 Jul; 426():117483. PubMed ID: 33989851 [TBL] [Abstract][Full Text] [Related]
10. Accuracy of CT perfusion-predicted core in the late window. Vidovich J; Voleti S; Zhang B; Stephens C; Sriwastwa A; Aziz Y; Corcoran B; Khandwala V; Mistry E; Khatri P; Wang LL; Vagal A Interv Neuroradiol; 2024 Apr; 30(2):250-254. PubMed ID: 36285452 [TBL] [Abstract][Full Text] [Related]
11. Total and regional ASPECT score for non-contrast CT, CT angiography, and CT perfusion: inter-rater agreement and its association with the final infarction in acute ischemic stroke patients. Chu Y; Ma G; Xu XQ; Lu SS; Cao YZ; Shi HB; Liu S; Wu FY Acta Radiol; 2022 Aug; 63(8):1093-1101. PubMed ID: 34219495 [TBL] [Abstract][Full Text] [Related]
12. Automated prediction of final infarct volume in patients with large-vessel occlusion acute ischemic stroke. Abdelkhaleq R; Kim Y; Khose S; Kan P; Salazar-Marioni S; Giancardo L; Sheth SA Neurosurg Focus; 2021 Jul; 51(1):E13. PubMed ID: 34198252 [TBL] [Abstract][Full Text] [Related]
13. Quantification of infarct core signal using CT imaging in acute ischemic stroke. Estrada UML; Meeks G; Salazar-Marioni S; Scalzo F; Farooqui M; Vivanco-Suarez J; Gutierrez SO; Sheth SA; Giancardo L Neuroimage Clin; 2022; 34():102998. PubMed ID: 35378498 [TBL] [Abstract][Full Text] [Related]
14. Prognosis with non-contrast CT and CT Perfusion imaging in thrombolysis-treated acute ischemic stroke. Chen X; Lin S; Zhang X; Hu S; Wang X Eur J Radiol; 2022 Apr; 149():110217. PubMed ID: 35183901 [TBL] [Abstract][Full Text] [Related]
15. Prognostic Accuracy of CTP Summary Maps in Patients with Large Vessel Occlusive Stroke and Poor Revascularization after Mechanical Thrombectomy-Comparison of Three Automated Perfusion Software Applications. Muehlen I; Borutta M; Siedler G; Engelhorn T; Hock S; Knott M; Hoelter P; Volbers B; Schwab S; Doerfler A Tomography; 2022 May; 8(3):1350-1362. PubMed ID: 35645395 [TBL] [Abstract][Full Text] [Related]
16. Automated CT Perfusion Ischemic Core Volume and Noncontrast CT ASPECTS (Alberta Stroke Program Early CT Score): Correlation and Clinical Outcome Prediction in Large Vessel Stroke. Haussen DC; Dehkharghani S; Rangaraju S; Rebello LC; Bouslama M; Grossberg JA; Anderson A; Belagaje S; Frankel M; Nogueira RG Stroke; 2016 Sep; 47(9):2318-22. PubMed ID: 27507858 [TBL] [Abstract][Full Text] [Related]
17. Automated ASPECTS in Acute Ischemic Stroke: A Comparative Analysis with CT Perfusion. Sundaram VK; Goldstein J; Wheelwright D; Aggarwal A; Pawha PS; Doshi A; Fifi JT; Leacy R; Mocco J; Puig J; Nael K AJNR Am J Neuroradiol; 2019 Dec; 40(12):2033-2038. PubMed ID: 31727750 [TBL] [Abstract][Full Text] [Related]
18. Non-contrast dual-energy CT virtual ischemia maps accurately estimate ischemic core size in large-vessel occlusive stroke. Wolman DN; van Ommen F; Tong E; Kauw F; Dankbaar JW; Bennink E; de Jong HWAM; Molvin L; Wintermark M; Heit JJ Sci Rep; 2021 Mar; 11(1):6745. PubMed ID: 33762589 [TBL] [Abstract][Full Text] [Related]
19. Alberta Stroke Program Early CT Score and collateral status predict target mismatch in large vessel occlusion with delayed time windows. Hang Y; Wang CD; Ni H; Cao Y; Zhao LB; Liu S; Shi HB; Jia Z J Neurointerv Surg; 2023 Sep; 15(9):876-880. PubMed ID: 35790373 [TBL] [Abstract][Full Text] [Related]