These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 3791911)

  • 1. A quality control system and its application to clinical chemistry.
    Schoen I; Graham G; Custer E
    Clin Lab Med; 1986 Dec; 6(4):625-48. PubMed ID: 3791911
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quality control log with CUSUM and clinically useful limits criteria.
    Schoen I; Custer E; Graham G; Bandi Z; Surovik MH
    Arch Pathol Lab Med; 1985 Apr; 109(4):333-9. PubMed ID: 3838642
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The accuracy of laboratory measurements in clinical chemistry: a study of 11 routine chemistry analytes in the College of American Pathologists Chemistry Survey with fresh frozen serum, definitive methods, and reference methods.
    Ross JW; Miller WG; Myers GL; Praestgaard J
    Arch Pathol Lab Med; 1998 Jul; 122(7):587-608. PubMed ID: 9674541
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Practical aspects of internal quality assurance.
    Uldall A
    Ann Ist Super Sanita; 1991; 27(3):411-7. PubMed ID: 1809060
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monitoring long-term analytical quality by computerized combined Shewart-cusum method.
    Solberg HE
    Scand J Clin Lab Invest Suppl; 1984; 172():43-9. PubMed ID: 6599529
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quality control in trace element analysis of clinical and biological samples. How good are your data?
    Cornelis R
    J Trace Elem Electrolytes Health Dis; 1992 Sep; 6(3):129-35. PubMed ID: 1483032
    [No Abstract]   [Full Text] [Related]  

  • 7. The quality assurance system in clinical chemistry.
    Albertini A; Signorini C
    Ann Ist Super Sanita; 1995; 31(1):3-8. PubMed ID: 8546372
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of criteria for the evaluation of reference method values.
    Stöckl D; Reinauer H
    Scand J Clin Lab Invest Suppl; 1993; 212():16-8. PubMed ID: 8465146
    [TBL] [Abstract][Full Text] [Related]  

  • 9. External quality assessment schemes for clinical chemistry in Germany.
    Reinauer H
    Ann Ist Super Sanita; 1995; 31(1):77-86. PubMed ID: 8546378
    [TBL] [Abstract][Full Text] [Related]  

  • 10. International Federation of Clinical Chemistry, Scientific Division: approved recommendation on the theory of reference values. Part 4. Control of analytical variation in the production, transfer and application of reference values.
    Solberg HE; Stamm D
    Eur J Clin Chem Clin Biochem; 1991 Aug; 29(8):531-5. PubMed ID: 1954308
    [No Abstract]   [Full Text] [Related]  

  • 11. Achieving accuracy for routine clinical chemistry methods by using patient specimen correlations to assign calibrator values. A means of managing matrix effects.
    Lasky FD
    Arch Pathol Lab Med; 1993 Apr; 117(4):412-9. PubMed ID: 8466405
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The stability of survey-assigned assay values when surveyed control materials are used in a daily interlaboratory quality control program. The College of American Pathologists Chemistry Survey--Quality Assurance Service shared pool experience.
    Lawson PL; Lawson NS; Ross JW
    Arch Pathol Lab Med; 1995 Apr; 119(4):312-33. PubMed ID: 7726725
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The impact of quality control materials on the performance of an internal quality control system: 1. General considerations.
    Hyltoft Petersen P; Hørder M; Blaabjerg O; Jørgensen PJ
    Scand J Clin Lab Invest Suppl; 1984; 172():65-9. PubMed ID: 6599531
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A quality control simulator for design and evaluation of internal quality control procedures.
    Groth T; Falk H; Westgard JO
    Scand J Clin Lab Invest Suppl; 1984; 172():195-201. PubMed ID: 6599523
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The impact of quality control materials on the performance of an internal quality control system: 2. Experiences from S-calcium analysis.
    Jørgensen PJ; Hørder M; Blaabjerg O; Hyltoft Petersen P; Haas V; Olsson V
    Scand J Clin Lab Invest Suppl; 1984; 172():71-7. PubMed ID: 6599532
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Serum chloride--a CAP survey.
    Geisinger KR; Geisinger KF; Wakely PE; Batsakis JG
    Am J Clin Pathol; 1980 Oct; 74(4 Suppl):546-51. PubMed ID: 7435446
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Probability and the Westgard Rules.
    Carroll TA; Pinnick HA; Carroll WE
    Ann Clin Lab Sci; 2003; 33(1):113-4. PubMed ID: 12661907
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calibration and quality control materials.
    Stamm D
    Z Klin Chem Klin Biochem; 1974 Apr; 12(4):137-45. PubMed ID: 4611073
    [No Abstract]   [Full Text] [Related]  

  • 19. International Federation of Clincal Chemistry. Committee of Standards. Expert panel on nomenclature and principles of quality control in clinical chemistry. Quality control in clinical chemistry. Part 4. Internal quality control.
    Clin Chim Acta; 1980 Sep; 106(1):109F-120F. PubMed ID: 7408204
    [No Abstract]   [Full Text] [Related]  

  • 20. Approaches for providing target values to improve usefulness of external quality assessment scheme. The Spanish experience.
    Ricós C; Alvarez V; Hernández A; Jimenez CV; Minchinela J; Perich C; Simon M; Serrano M
    Scand J Clin Lab Invest Suppl; 1993; 212():19-27. PubMed ID: 8465147
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.