These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
203 related articles for article (PubMed ID: 37920889)
21. Efficacy and Safety of Lumen Apposing Self-Expandable Metal Stents for EUS Guided Cholecystostomy: A Meta-Analysis and Systematic Review. Kalva NR; Vanar V; Forcione D; Bechtold ML; Puli SR Can J Gastroenterol Hepatol; 2018; 2018():7070961. PubMed ID: 29850458 [TBL] [Abstract][Full Text] [Related]
22. Endoscopic Management of Acute Cholecystitis. Luo X; Sharaiha R; Teoh AYB Gastrointest Endosc Clin N Am; 2022 Jul; 32(3):527-543. PubMed ID: 35691695 [TBL] [Abstract][Full Text] [Related]
23. Safety and clinical outcomes of endoscopic ultrasound-guided gallbladder drainage with lumen-apposing metal stents in patients with dwell time over one year. Yuste RT; García-Alonso FJ; Sánchez-Ocana R; Cimavilla M; Herrero IP; Carbajo AY; Sanz MB; Higuera CS; Pérez-Miranda M Ann Gastroenterol; 2019; 32(5):514-521. PubMed ID: 31474799 [TBL] [Abstract][Full Text] [Related]
24. Conversion of Percutaneous Cholecystostomy to Internal Transmural Gallbladder Drainage Using an Endoscopic Ultrasound-Guided, Lumen-Apposing Metal Stent. Law R; Grimm IS; Stavas JM; Baron TH Clin Gastroenterol Hepatol; 2016 Mar; 14(3):476-80. PubMed ID: 26528802 [TBL] [Abstract][Full Text] [Related]
25. Endosonography-guided gallbladder drainage versus percutaneous cholecystostomy in very high-risk surgical patients with acute cholecystitis: an international randomised multicentre controlled superiority trial (DRAC 1). Teoh AYB; Kitano M; Itoi T; Pérez-Miranda M; Ogura T; Chan SM; Serna-Higuera C; Omoto S; Torres-Yuste R; Tsuichiya T; Wong KT; Leung CH; Chiu PWY; Ng EKW; Lau JYW Gut; 2020 Jun; 69(6):1085-1091. PubMed ID: 32165407 [TBL] [Abstract][Full Text] [Related]
26. Safety and efficacy of endoscopic ultrasound-guided gallbladder drainage combined with endoscopic retrograde cholangiopancreatography in the same session. Torres Yuste R; Garcia-Alonso FJ; Sanchez-Ocana R; Cimavilla Roman M; Peñas Herrero I; Carbajo AY; De Benito Sanz M; Mora Cuadrado N; De la Serna Higuera C; Perez-Miranda M Dig Endosc; 2020 May; 32(4):608-615. PubMed ID: 31608503 [TBL] [Abstract][Full Text] [Related]
27. Endoscopic biliary drainage in unresectable biliary obstruction: the role of endoscopic ultrasound-guidance in a cohort study. Puga M; Pallarès N; Velásquez-Rodríguez J; García-Sumalla A; Consiglieri CF; Busquets J; Laquente B; Calvo M; Fabregat J; Castellote J; Gornals JB Rev Esp Enferm Dig; 2019 Sep; 111(9):683-689. PubMed ID: 31333037 [TBL] [Abstract][Full Text] [Related]
28. Long-term outcomes after endoscopic ultrasonography-guided gallbladder drainage for acute cholecystitis. Choi JH; Lee SS; Choi JH; Park DH; Seo DW; Lee SK; Kim MH Endoscopy; 2014 Aug; 46(8):656-61. PubMed ID: 24977397 [TBL] [Abstract][Full Text] [Related]
29. Endoscopic ultrasound-guided gallbladder drainage for acute cholecystitis with a lumen-apposing metal stent: a systematic review of case series. Manta R; Mutignani M; Galloro G; Conigliaro R; Zullo A Eur J Gastroenterol Hepatol; 2018 Jul; 30(7):695-698. PubMed ID: 29578866 [TBL] [Abstract][Full Text] [Related]
30. A novel electrocautery-enhanced delivery system for one-step endoscopic ultrasound-guided drainage of the gallbladder and bile duct using a lumen-apposing metal stent: a feasibility study. Yoo HW; Moon JH; Jo SJ; Lee YN; Park JK; Lee TH; Cha SW; Cho YD; Park SH; Park SI; Jeong S; Lee DH Endoscopy; 2021 Sep; 53(9):922-926. PubMed ID: 33336343 [TBL] [Abstract][Full Text] [Related]
31. Use of endoscopic ultrasound-guided gallbladder drainage as a rescue approach in cases of unsuccessful biliary drainage. Fugazza A; Khalaf K; Pawlak KM; Spadaccini M; Colombo M; Andreozzi M; Giacchetto M; Carrara S; Ferrari C; Binda C; Mangiavillano B; Anderloni A; Repici A World J Gastroenterol; 2024 Jan; 30(1):70-78. PubMed ID: 38293324 [TBL] [Abstract][Full Text] [Related]
32. Clinical efficacy and safety of endoscopic ultrasound-guided gallbladder drainage replacement of percutaneous drainage: A multicenter retrospective study. Minaga K; Yamashita Y; Ogura T; Takenaka M; Shimokawa Y; Hisa T; Itonaga M; Kato H; Nishikiori H; Okuda A; Matsumoto H; Uenoyama Y; Watanabe T; Chiba Y; Higuchi K; Kudo M; Kitano M Dig Endosc; 2019 Mar; 31(2):180-187. PubMed ID: 30039611 [TBL] [Abstract][Full Text] [Related]
33. International collaborative study on EUS-guided gallbladder drainage: Are we ready for prime time? Kahaleh M; Perez-Miranda M; Artifon EL; Sharaiha RZ; Kedia P; Peñas I; De la Serna C; Kumta NA; Marson F; Gaidhane M; Boumitri C; Parra V; Rondon Clavo CM; Giovannini M Dig Liver Dis; 2016 Sep; 48(9):1054-7. PubMed ID: 27328985 [TBL] [Abstract][Full Text] [Related]
34. Outcomes of endoscopic ultrasound-guided gallbladder drainage: A multicenter study from India (with video). Chavan R; Singla V; Sundaram S; Zanwar S; Shah C; Sud S; Singh P; Gandhi C; Bhatt P; Goel A; Rajput S Indian J Gastroenterol; 2024 Dec; 43(6):1184-1193. PubMed ID: 38902473 [TBL] [Abstract][Full Text] [Related]
35. Safety issues in endoscopy ultrasound-guided interventions using lumen apposing metal stents. Auriemma F; Fugazza A; Colombo M; Spadaccini M; Repici A; Anderloni A Minerva Gastroenterol (Torino); 2022 Jun; 68(2):177-185. PubMed ID: 33871222 [TBL] [Abstract][Full Text] [Related]
36. Comparison of the long-term outcomes of EUS-guided gallbladder drainage and endoscopic transpapillary gallbladder drainage for calculous cholecystitis in poor surgical candidates: a multicenter propensity score-matched analysis. Inoue T; Yoshida M; Suzuki Y; Kitano R; Urakabe K; Haneda K; Okumura F; Naitoh I Gastrointest Endosc; 2023 Sep; 98(3):362-370. PubMed ID: 37059367 [TBL] [Abstract][Full Text] [Related]
37. Lumen-apposing metal stents for malignant biliary obstruction: Is this the ultimate horizon of our experience? Anderloni A; Troncone E; Fugazza A; Cappello A; Del Vecchio Blanco G; Monteleone G; Repici A World J Gastroenterol; 2019 Aug; 25(29):3857-3869. PubMed ID: 31413524 [TBL] [Abstract][Full Text] [Related]
38. Adverse events with lumen-apposing metal stents in endoscopic gallbladder drainage: A systematic review and meta-analysis. Mohan BP; Asokkumar R; Shakhatreh M; Garg R; Ponnada S; Navaneethan U; Adler DG Endosc Ultrasound; 2019; 8(4):241-248. PubMed ID: 31115387 [TBL] [Abstract][Full Text] [Related]
39. Endoscopic ultrasound-guided gallbladder drainage for acute cholecystitis: Long-term outcomes after removal of a self-expandable metal stent. Kamata K; Takenaka M; Kitano M; Omoto S; Miyata T; Minaga K; Yamao K; Imai H; Sakurai T; Watanabe T; Nishida N; Kudo M World J Gastroenterol; 2017 Jan; 23(4):661-667. PubMed ID: 28216973 [TBL] [Abstract][Full Text] [Related]
40. WONDER-02: plastic stent vs. lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic pseudocysts-study protocol for a multicentre randomised non-inferiority trial. Saito T; Takenaka M; Kuwatani M; Doi S; Ohyama H; Fujisawa T; Masuda A; Iwashita T; Shiomi H; Hayashi N; Iwata K; Maruta A; Mukai T; Matsubara S; Hamada T; Inoue T; Matsumoto K; Hirose S; Fujimori N; Kashiwabara K; Kamada H; Hashimoto S; Shiratori T; Yamada R; Kogure H; Nakahara K; Ogura T; Kitano M; Yasuda I; Isayama H; Nakai Y; Trials; 2024 Aug; 25(1):559. PubMed ID: 39182137 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]