These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 37925854)
21. Shape optimization of stress concentration-free lattice for self-expandable Nitinol stent-grafts. Masoumi Khalil Abad E; Pasini D; Cecere R J Biomech; 2012 Apr; 45(6):1028-35. PubMed ID: 22304844 [TBL] [Abstract][Full Text] [Related]
22. [Optimization based on finite element technique of nitinol stent]. Lin F; Liu X; Huang N; Gao Q; Li Z; Yao T; Luo Q; Huang J Zhongguo Yi Liao Qi Xie Za Zhi; 2014 Mar; 38(2):98-101. PubMed ID: 24941770 [TBL] [Abstract][Full Text] [Related]
23. Patient-Specific Immersed Finite Element-Difference Model of Transcatheter Aortic Valve Replacement. Brown JA; Lee JH; Smith MA; Wells DR; Barrett A; Puelz C; Vavalle JP; Griffith BE Ann Biomed Eng; 2023 Jan; 51(1):103-116. PubMed ID: 36264408 [TBL] [Abstract][Full Text] [Related]
24. Visions of TAVR Future: Development and Optimization of a Second Generation Novel Polymeric TAVR. Kovarovic B; Helbock R; Baylous K; Rotman OM; Slepian MJ; Bluestein D J Biomech Eng; 2022 Jun; 144(6):. PubMed ID: 35318480 [TBL] [Abstract][Full Text] [Related]
25. Multi-objective optimization of nitinol stent design. Alaimo G; Auricchio F; Conti M; Zingales M Med Eng Phys; 2017 Sep; 47():13-24. PubMed ID: 28705512 [TBL] [Abstract][Full Text] [Related]
26. Novel stent design for transcatheter mitral valve implantation. Loger K; Pokorny S; Schaller T; Haben I; Frank D; Lutter G Interact Cardiovasc Thorac Surg; 2018 Feb; 26(2):190-195. PubMed ID: 29361168 [TBL] [Abstract][Full Text] [Related]
27. Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion. Abbasi M; Azadani AN J Biomech; 2015 Oct; 48(13):3663-71. PubMed ID: 26338100 [TBL] [Abstract][Full Text] [Related]
28. Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage. Lavon K; Marom G; Bianchi M; Halevi R; Hamdan A; Morany A; Raanani E; Bluestein D; Haj-Ali R Med Biol Eng Comput; 2019 Oct; 57(10):2129-2143. PubMed ID: 31372826 [TBL] [Abstract][Full Text] [Related]
29. Deformation of Transcatheter Aortic Valve Prostheses: Implications for Hypoattenuating Leaflet Thickening and Clinical Outcomes. Fukui M; Bapat VN; Garcia S; Dworak MW; Hashimoto G; Sato H; Gössl M; Enriquez-Sarano M; Lesser JR; Cavalcante JL; Sorajja P Circulation; 2022 Aug; 146(6):480-493. PubMed ID: 35862182 [TBL] [Abstract][Full Text] [Related]
30. The consequences of the mechanical environment of peripheral arteries for nitinol stenting. Early M; Kelly DJ Med Biol Eng Comput; 2011 Nov; 49(11):1279-88. PubMed ID: 21833628 [TBL] [Abstract][Full Text] [Related]
31. Design and evaluation of the crimping of a hooked self-expandable caval valve stent for the treatment of tricuspid regurgitation. Praveen Kumar G; Liang Leo H; Cui F Comput Methods Biomech Biomed Engin; 2019 Apr; 22(5):533-546. PubMed ID: 30773049 [TBL] [Abstract][Full Text] [Related]
32. Multi-Objective Optimization of Bioresorbable Magnesium Alloy Stent by Kriging Surrogate Model. Wang H; Jiao L; Sun J; Yan P; Wang X; Qiu T Cardiovasc Eng Technol; 2022 Dec; 13(6):829-839. PubMed ID: 35414048 [TBL] [Abstract][Full Text] [Related]
33. High resolution three-dimensional strain mapping of bioprosthetic heart valves using digital image correlation. Abbasi M; Qiu D; Behnam Y; Dvir D; Clary C; Azadani AN J Biomech; 2018 Jul; 76():27-34. PubMed ID: 29807762 [TBL] [Abstract][Full Text] [Related]
34. Stent fractures after common femoral artery bail-out stenting due to suture device failure in TAVR. Veulemans V; Afzal S; Ledwig P; Heiss C; Busch L; Sansone R; Soetemann DB; Maier O; Kleinebrecht L; Kelm M; Zeus T; Hellhammer K Vasa; 2018 Aug; 47(5):393-401. PubMed ID: 29952252 [TBL] [Abstract][Full Text] [Related]
35. Fatigue behaviour of Nitinol peripheral stents: the role of plaque shape studied with computational structural analyses. Dordoni E; Meoli A; Wu W; Dubini G; Migliavacca F; Pennati G; Petrini L Med Eng Phys; 2014 Jul; 36(7):842-9. PubMed ID: 24721457 [TBL] [Abstract][Full Text] [Related]
37. Finite element comparison of performance related characteristics of balloon expandable stents. Donnelly EW; Bruzzi MS; Connolley T; McHugh PE Comput Methods Biomech Biomed Engin; 2007 Apr; 10(2):103-10. PubMed ID: 18651276 [TBL] [Abstract][Full Text] [Related]
38. Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations. Bosi GM; Capelli C; Cheang MH; Delahunty N; Mullen M; Taylor AM; Schievano S J Biomech; 2018 Apr; 71():236-244. PubMed ID: 29482928 [TBL] [Abstract][Full Text] [Related]
39. Pathology of balloon-expandable and self-expanding stents following MRI-guided transapical aortic valve replacement. Kindzelski BA; Li M; Mazilu D; Horvath KA J Heart Valve Dis; 2015 Mar; 24(2):139-47. PubMed ID: 26204676 [TBL] [Abstract][Full Text] [Related]
40. Outcomes Following Transcatheter Aortic Valve Replacement for Degenerative Stentless Versus Stented Bioprostheses. Duncan A; Moat N; Simonato M; de Weger A; Kempfert J; Eggebrecht H; Walton A; Hellig F; Kornowski R; Spargias K; Mendiz O; Makkar R; Guerrero M; Rihal C; George I; Don C; Iadanza A; Bapat V; Welsh R; Wijeysundera HC; Wood D; Sathananthan J; Danenberg H; Maisano F; Garcia S; Gafoor S; Nombela-Franco L; Cobiella J; Dvir D JACC Cardiovasc Interv; 2019 Jul; 12(13):1256-1263. PubMed ID: 31202944 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]