128 related articles for article (PubMed ID: 37929802)
1. High-resolution three-dimensional dosimetry in clinically relevant volumes utilizing optically stimulated luminescence.
Jensen ML; Julsgaard B; Turtos RM; Skyt PS; Jensen MB; Muren LP; Balling P
Med Phys; 2024 Mar; 51(3):2200-2209. PubMed ID: 37929802
[TBL] [Abstract][Full Text] [Related]
2. New optically stimulated luminescence dosimetry film optimized for energy dependence guided by Monte Carlo simulations.
De Saint-Hubert M; Caprioli M; de Freitas Nascimento L; Delombaerde L; Himschoot K; Vandenbroucke D; Leblans P; Crijns W
Phys Med Biol; 2024 Mar; 69(7):. PubMed ID: 38394683
[TBL] [Abstract][Full Text] [Related]
3. Optically stimulated luminescence in state-of-the-art LYSO:Ce scintillators enables high spatial resolution 3D dose imaging.
Jensen ML; Nyemann JS; Muren LP; Julsgaard B; Balling P; Turtos RM
Sci Rep; 2022 May; 12(1):8301. PubMed ID: 35585168
[TBL] [Abstract][Full Text] [Related]
4. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy.
Schembri V; Heijmen BJ
Med Phys; 2007 Jun; 34(6):2113-8. PubMed ID: 17654914
[TBL] [Abstract][Full Text] [Related]
5. 3D Dosimetry Based on LiMgPO
Sądel M; Gajewski J; Sowa U; Swakoń J; Kajdrowicz T; Bilski P; Kłosowski M; Pędracka A; Horwacik T
Sensors (Basel); 2021 Sep; 21(18):. PubMed ID: 34577220
[TBL] [Abstract][Full Text] [Related]
6. Optically stimulated luminescence detectors for dosimetry and LET measurements in light ion beams.
Christensen JB; Muñoz ID; Bassler N; Stengl C; Bossin L; Togno M; Safai S; Jäkel O; Yukihara EG
Phys Med Biol; 2023 Jul; 68(15):. PubMed ID: 37336242
[No Abstract] [Full Text] [Related]
7. High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimeters.
Yukihara EG; Yoshimura EM; Lindstrom TD; Ahmad S; Taylor KK; Mardirossian G
Phys Med Biol; 2005 Dec; 50(23):5619-28. PubMed ID: 16306656
[TBL] [Abstract][Full Text] [Related]
8. Relative energy response of indigenously developed optically stimulated luminescence dosimeters Al
Kumar P; Dhabekar B; Sharma SD; Mishra DR; Rawat NS; Kadam S; Chaudhari S; Chandola RM; Agrawal S
Luminescence; 2020 Dec; 35(8):1217-1222. PubMed ID: 32515166
[TBL] [Abstract][Full Text] [Related]
9. Calibration and time fading characterization of a new optically stimulated luminescence film dosimeter.
Caprioli M; Delombaerde L; De Saint-Hubert M; de Freitas Nascimento L; De Roover R; Himschoot K; van der Heyden B; Vandenbroucke D; Leblans P; Crijns W
Med Phys; 2023 Feb; 50(2):1185-1193. PubMed ID: 36353946
[TBL] [Abstract][Full Text] [Related]
10. Multi-institutional dose audit in radiotherapy facilities using in-house developed optically stimulated luminescence disc dosimeters.
Kumar P; Sharma SD; Dhabekar B; Rawat NS; Mishra DR; Chaudhari S; Chandola RM; Routh T; Agrawal S
J Cancer Res Ther; 2023 Apr; 19(Supplement):S0. PubMed ID: 37147959
[TBL] [Abstract][Full Text] [Related]
11. A Novel Nanocomposite Material for Optically Stimulated Luminescence Dosimetry.
Nielsen CL; Turtos RM; Bondesgaard M; Nyemann JS; Jensen ML; Iversen BB; Muren LP; Julsgaard B; Balling P
Nano Lett; 2022 Feb; 22(4):1566-1572. PubMed ID: 35130696
[TBL] [Abstract][Full Text] [Related]
12. A reusable OSL-film for 2D radiotherapy dosimetry.
Wouter C; Dirk V; Paul L; Tom D
Phys Med Biol; 2017 Oct; 62(21):8441-8454. PubMed ID: 29047456
[TBL] [Abstract][Full Text] [Related]
13. Al
Christensen JB; Togno M; Nesteruk KP; Psoroulas S; Meer D; Weber DC; Lomax T; Yukihara EG; Safai S
Phys Med Biol; 2021 Apr; 66(8):. PubMed ID: 33571973
[TBL] [Abstract][Full Text] [Related]
14. Experimentally determined and Monte Carlo-calculated energy dependence of NaCl pellets read by optically stimulated luminescence for photon beams in the energy range 30 keV to 1.25 MeV.
Waldner L; Rääf C; Hinrichsen Y; Herrnsdorf L; Bernhardsson C
J Radiol Prot; 2020 Nov; 40(4):. PubMed ID: 33045684
[TBL] [Abstract][Full Text] [Related]
15. APPLICATIONS OF OPTICALLY STIMULATED LUMINESCENCE IN MEDICAL DOSIMETRY.
Yukihara EG; Kron T
Radiat Prot Dosimetry; 2020 Dec; 192(2):122-138. PubMed ID: 33412585
[TBL] [Abstract][Full Text] [Related]
16. Dosimetric characterization of optically stimulated luminescence dosimeter with therapeutic photon beams for use in clinical radiotherapy measurements.
Ponmalar R; Manickam R; Ganesh KM; Saminathan S; Raman A; Godson HF
J Cancer Res Ther; 2017; 13(2):304-312. PubMed ID: 28643752
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy.
Yukihara EG; Mardirossian G; Mirzasadeghi M; Guduru S; Ahmad S
Med Phys; 2008 Jan; 35(1):260-9. PubMed ID: 18293581
[TBL] [Abstract][Full Text] [Related]
18. Image reconstruction algorithm for optically stimulated luminescence 2D dosimetry using laser-scanned Al
Ahmed MF; Schnell E; Ahmad S; Yukihara EG
Phys Med Biol; 2016 Oct; 61(20):7484-7506. PubMed ID: 27694704
[TBL] [Abstract][Full Text] [Related]
19. Near-real-time radiotherapy dosimetry using optically stimulated luminescence of Al2O3:C: mathematical models and preliminary results.
Gaza R; McKeever SW; Akselrod MS
Med Phys; 2005 Apr; 32(4):1094-102. PubMed ID: 15895594
[TBL] [Abstract][Full Text] [Related]
20. Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology.
Ruan C; Yukihara EG; Clouse WJ; Gasparian PB; Ahmad S
Med Phys; 2010 Jul; 37(7):3560-8. PubMed ID: 20831063
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]