133 related articles for article (PubMed ID: 37930399)
21. Body mass index is related to unsuccessful puncture attempts and failure to axillary vein cannulation during ultrasound-guided cardiac electronic device implantation.
De Sensi F; Addonisio L; Baratta P; Breschi M; Cresti A; Miracapillo G; Limbruno U
J Interv Card Electrophysiol; 2021 Aug; 61(2):253-259. PubMed ID: 32572722
[TBL] [Abstract][Full Text] [Related]
22. Ultrasound-guided left brachiocephalic vein cannulation in children with underlying bleeding disorders: a retrospective analysis.
Di Nardo M; Stoppa F; Marano M; Ricci Z; Barbieri MA; Cecchetti C
Pediatr Crit Care Med; 2014 Feb; 15(2):e44-8. PubMed ID: 24201856
[TBL] [Abstract][Full Text] [Related]
23. Effectiveness and complications of ultrasound-guided subclavian vein cannulation in children and neonates.
Nardi N; Wodey E; Laviolle B; De La Brière F; Delahaye S; Engrand C; Gauvrit C; Dessard S; Defontaine A; Ecoffey C
Anaesth Crit Care Pain Med; 2016 Jun; 35(3):209-13. PubMed ID: 26924612
[TBL] [Abstract][Full Text] [Related]
24. Catheterization of the radial or brachial artery in neonates and infants.
Schindler E; Kowald B; Suess H; Niehaus-Borquez B; Tausch B; Brecher A
Paediatr Anaesth; 2005 Aug; 15(8):677-82. PubMed ID: 16029403
[TBL] [Abstract][Full Text] [Related]
25. Ultrasound-guided central venous cannulation in infants weighing less than 5 kilograms.
Di Nardo M; Tomasello C; Pittiruti M; Perrotta D; Marano M; Cecchetti C; Pasotti E; Pirozzi N; Stoppa F
J Vasc Access; 2011; 12(4):321-4. PubMed ID: 21553391
[TBL] [Abstract][Full Text] [Related]
26. Comparison of ultrasound-guided femoral artery cannulation versus palpation technique in neonates undergoing cardiac surgery.
Salık F; Bıçak M
J Vasc Access; 2023 Jan; 24(1):27-34. PubMed ID: 34082593
[TBL] [Abstract][Full Text] [Related]
27. Ultrasound-Guided Long-Axis Versus Short-Axis Femoral Artery Catheterization in Neonates and Infants Undergoing Cardiac Surgery: A Randomized Controlled Study.
Abdelbaser I; Mageed NA; Elmorsy MM; Elfayoumy SI
J Cardiothorac Vasc Anesth; 2022 Mar; 36(3):677-683. PubMed ID: 34148802
[TBL] [Abstract][Full Text] [Related]
28. "Modified Dynamic Needle Tip Positioning" Short-Axis, Out-of-Plane, Ultrasound-Guided Radial Artery Cannulation in Neonates: A Randomized Controlled Trial.
Liu L; Tan Y; Li S; Tian J
Anesth Analg; 2019 Jul; 129(1):178-183. PubMed ID: 29787409
[TBL] [Abstract][Full Text] [Related]
29. Feasibility of the ultrasound-guided supraclavicular cannulation of the brachiocephalic vein in very small weight infants: A case series.
Breschan C; Graf G; Arneitz C; Stettner H; Feigl G; Neuwersch S; Stadik C; Koestenberger M; Holasek S; Likar R
Paediatr Anaesth; 2020 Aug; 30(8):928-933. PubMed ID: 32449570
[TBL] [Abstract][Full Text] [Related]
30. Efficacy and safety of ultrasound-guided internal jugular vein catheterization in low birth weight newborn.
Montes-Tapia F; Rodríguez-Taméz A; Cura-Esquivel I; Barreto-Arroyo I; Hernández-Garduño A; Rodríguez-Balderrama I; Quero J; de la O-Cavazos M
J Pediatr Surg; 2016 Oct; 51(10):1700-3. PubMed ID: 27292594
[TBL] [Abstract][Full Text] [Related]
31. Ultrasound-guided external jugular vein cannulation for central venous access by inexperienced trainees.
Mitre CI; Golea A; Acalovschi I; Mocan T; Caea AM; Ruţă C; Mariana M
Eur J Anaesthesiol; 2010 Mar; 27(3):300-3. PubMed ID: 19935072
[TBL] [Abstract][Full Text] [Related]
32. Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization.
Brass P; Hellmich M; Kolodziej L; Schick G; Smith AF
Cochrane Database Syst Rev; 2015 Jan; 1(1):CD011447. PubMed ID: 25575245
[TBL] [Abstract][Full Text] [Related]
33. Guidewire-assisted vs. direct radial arterial cannulation in neonates and infants: A randomised controlled trial.
Jang YE; Kim EH; Lee JH; Kim HS; Kim JT
Eur J Anaesthesiol; 2019 Oct; 36(10):738-744. PubMed ID: 31356376
[TBL] [Abstract][Full Text] [Related]
34. [Ultrasound-guided cannulation or by pulse palpation in the intensive care unit].
Oulego-Erroz I; Mayordomo-Colunga J; González-Cortés R; Sánchez-Porras M; Llorente-de la Fuente A; Fernández-de Miguel S; Balaguer-Gargallo M; Frías-Pérez M; Rodríguez-Nuñez A; ;
An Pediatr (Engl Ed); 2021 Mar; 94(3):144-152. PubMed ID: 32063513
[TBL] [Abstract][Full Text] [Related]
35. Ultrasound-guided femoral vascular access in pediatric cardiac catheterization.
Go K; Kojima T; Watanabe F
Pediatr Int; 2023 Jan; 65(1):e15446. PubMed ID: 36528863
[TBL] [Abstract][Full Text] [Related]
36. Ultrasound guided percutaneous internal jugular vein access in neonatal intensive care unit patients.
Oh C; Lee S; Seo JM; Lee SK
J Pediatr Surg; 2016 Apr; 51(4):570-2. PubMed ID: 26522898
[TBL] [Abstract][Full Text] [Related]
37. Implementation and Evaluation of Training for Ultrasound-Guided Vascular Access to Small Vessels Using a Low-Cost Cadaver Model.
Wagner M; Hauser K; Cardona F; Schmölzer GM; Berger A; Olischar M; Werther T
Pediatr Crit Care Med; 2018 Nov; 19(11):e611-e617. PubMed ID: 30234738
[TBL] [Abstract][Full Text] [Related]
38. Ultrasound guidance improves the success rate of internal jugular vein cannulation. A prospective, randomized trial.
Mallory DL; McGee WT; Shawker TH; Brenner M; Bailey KR; Evans RG; Parker MM; Farmer JC; Parillo JE
Chest; 1990 Jul; 98(1):157-60. PubMed ID: 2193776
[TBL] [Abstract][Full Text] [Related]
39. Effects of vascular morphological features and ultrasound-guided vascular cannulation techniques on the success of femoral artery catheterisation in newborns.
Boran OF; Urfalıoglu A; Arslan M; Yazar FM; Bilal B; Orak Y; Eroğlu E
J Clin Monit Comput; 2020 Jun; 34(3):607-614. PubMed ID: 32100161
[TBL] [Abstract][Full Text] [Related]
40. Landmark versus ultrasound-guided insertion of femoral venous catheters in the pediatric intensive care unit: An efficacy and safety comparison study.
Pietroboni PF; Carvajal CM; Zuleta YI; Ortiz PL; Lucero YC; Drago M; vonDessauer B
Med Intensiva (Engl Ed); 2020 Mar; 44(2):96-100. PubMed ID: 31630916
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]