These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 3793284)

  • 1. The cardiac pigtail catheter.
    Patridge JB
    Int J Cardiol; 1986 Nov; 13(2):252-6. PubMed ID: 3793284
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved left ventriculography with the new 5F helical-tip Halo catheter.
    Caracciolo EA; Kern MJ; Collis WC; Bach RG; Donohue TJ; Mechem C; Aguire FV
    Am Heart J; 1994 Oct; 128(4):724-32. PubMed ID: 7524294
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Contrast cine left ventriculography: comparison of two pigtail catheter shapes and analysis of factors determining the final quality.
    Deligonul U; Jones S; Shurmur S; Oskarsson H
    Cathet Cardiovasc Diagn; 1996 Apr; 37(4):428-33. PubMed ID: 8721699
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reduced incidence of ventricular ectopy with a 4F Halo catheter during pediatric cardiac catheterization.
    Geggel RL; Hijazi ZM
    Cathet Cardiovasc Diagn; 1998 Jan; 43(1):55-7. PubMed ID: 9473191
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Usefulness of newly designed pigtail catheter with multiple side holes by reducing incidence of ventricular ectopy.
    Hirose M; Shimada K; Sakanoue Y; Hirata K; Takeuchi K; Yoshikawa J
    Catheter Cardiovasc Interv; 1999 Oct; 48(2):220-5. PubMed ID: 10506786
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Right heart pigtail catheter for selective angiocardiography.
    Kiel EA; Victorica BE
    Pediatr Cardiol; 1983; 4(3):247-9. PubMed ID: 6647112
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An improved method for transseptal left ventricular catheterization.
    Kawachi K; Kitamura S; Oyama C; Koh S; Morita R; Kawashima Y
    Cathet Cardiovasc Diagn; 1983; 9(3):303-8. PubMed ID: 6883503
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tantalum labelling in vivo of cardiac ventricular chambers in dogs.
    Lipton MJ; Ringertz HG; Holt RG; Carlsson E
    Acta Radiol Diagn (Stockh); 1979; 20(5):721-6. PubMed ID: 525413
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Catheter device for safer selective retrograde cardiography of the left ventricle].
    Maeda H; Kimura S; Hayashi K; Kato S
    Rinsho Hoshasen; 1973 Sep; 18(9):663-6. PubMed ID: 4797210
    [No Abstract]   [Full Text] [Related]  

  • 10. Modified technique of transseptal left heart catheterization.
    Croft CH; Lipscomb K
    J Am Coll Cardiol; 1985 Apr; 5(4):904-10. PubMed ID: 3973292
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of a temporary cardiac pacing catheter in the left ventricle by chest X-ray.
    Curry RC; Sabom MB; Bream PR
    Rev Interam Radiol; 1977 Oct; 2(4):239-41. PubMed ID: 594558
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac catheter guided surgical closure of an apical ventricular septal defect.
    Thomson JD; Gibbs JL; Van Doorn C
    Ann Thorac Surg; 2000 Oct; 70(4):1402-4. PubMed ID: 11081911
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multipurpose A2 catheter approach to left heart catheterization in severe aortic stenosis.
    Nicholson WJ
    Clin Cardiol; 1988 Oct; 11(10):697-700. PubMed ID: 3224452
    [TBL] [Abstract][Full Text] [Related]  

  • 14. "End-hole" pigtail catheter: an unusual complication of left ventriculography.
    Hilton TC; Deligonul U; Aguirre F; Kern MJ
    Cathet Cardiovasc Diagn; 1991 Jun; 23(2):139-40. PubMed ID: 2070403
    [No Abstract]   [Full Text] [Related]  

  • 15. Concomitant stenting of the patent ductus arteriosus and radiofrequency valvotomy in pulmonary atresia with intact ventricular septum and intermediate right ventricle: early in-hospital and medium-term outcomes.
    Alwi M; Choo KK; Radzi NA; Samion H; Pau KK; Hew CC
    J Thorac Cardiovasc Surg; 2011 Jun; 141(6):1355-61. PubMed ID: 21227471
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Extrasystole during left ventriculography. Incidence in relation to programmed injection and type of catheter].
    Esplugas E; Pujol M; CurĂ³s A; Barthe JE; Pallares C
    Rev Esp Cardiol; 1982; 35(3):247-9. PubMed ID: 6182591
    [No Abstract]   [Full Text] [Related]  

  • 17. Anomalous origin of both pulmonary arteries from the ascending aorta with a nonbranching main pulmonary artery arising from the right ventricle.
    Aotsuka H; Nagai Y; Saito M; Matsumoto H; Nakamura T
    Pediatr Cardiol; 1990 Jul; 11(3):156-8. PubMed ID: 2395745
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Emergency guide wire pacing: new methods for rapid conversion of a cardiac catheter into a pacemaker.
    Gessman LJ; Gallagher JD; MacMillan RM; Morse D; Clark DL; Maranhao V
    Pacing Clin Electrophysiol; 1984 Sep; 7(5):917-21. PubMed ID: 6207504
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intra-atrial malpositions of Silastic catheters in newborns.
    Hausdorf G; Bitzan M; Commentz J; Seitz C; Stegner H; Stern M; Veelken N; Hellwege HH
    Crit Care Med; 1987 Apr; 15(4):308-9. PubMed ID: 3816275
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Myocardial and pericardial staining by transradial Optitorque Jacky shape catheter during left ventriculogram.
    Basit A; Nazir R; Hahn H
    J Invasive Cardiol; 2012 Mar; 24(3):128. PubMed ID: 22388306
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.