These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 37956015)

  • 1. Fascicle-Selective Ultrasound-Powered Bidirectional Wireless Peripheral Nerve Interface IC.
    Xu J; Filho JS; Nag S; Long L; Hwang E; Tejeiro C; O'Leary G; Huang Y; Kanchwala M; Abdolrazzaghi M; Tang C; Liu P; Sui Y; You H; Liu X; Zariffa J; Genov R
    IEEE Trans Biomed Circuits Syst; 2023 Dec; 17(6):1237-1256. PubMed ID: 37956015
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Minimally-Invasive Neural Interface for Distributed Wireless Electrocorticogram Recording Systems.
    Chang SI; Park SY; Yoon E
    Sensors (Basel); 2018 Jan; 18(1):. PubMed ID: 29342103
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Wireless Headstage System Based on Neural-Recording Chip Featuring 315 nW Kickback-Reduction SAR ADC.
    Zhang Y; Yang C; Sun J; Li Z; Gao H; Luo Y; Xu K; Pan G; Zhao B
    IEEE Trans Biomed Circuits Syst; 2023 Feb; 17(1):105-115. PubMed ID: 36423310
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 700mV low power low noise implantable neural recording system design.
    An G; Hutchens C; Rennaker RL
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6557-60. PubMed ID: 25571498
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fully implantable neural recording and stimulation interfaces: Peripheral nerve interface applications.
    Deshmukh A; Brown L; Barbe MF; Braverman AS; Tiwari E; Hobson L; Shunmugam S; Armitage O; Hewage E; Ruggieri MR; Morizio J
    J Neurosci Methods; 2020 Mar; 333():108562. PubMed ID: 31862376
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A low-power 32-channel digitally programmable neural recording integrated circuit.
    Wattanapanitch W; Sarpeshkar R
    IEEE Trans Biomed Circuits Syst; 2011 Dec; 5(6):592-602. PubMed ID: 23852555
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Selective chronic recording in small nerve fascicles of sciatic nerve with carbon nanotube yarns in rats.
    Kotamraju BP; Eggers TE; McCallum GA; Durand DM
    J Neural Eng; 2024 Jan; 20(6):. PubMed ID: 38100824
    [No Abstract]   [Full Text] [Related]  

  • 8. Wearable wireless power systems for 'ME-BIT' magnetoelectric-powered bio implants.
    Alrashdan FT; Chen JC; Singer A; Avants BW; Yang K; Robinson JT
    J Neural Eng; 2021 Jul; 18(4):. PubMed ID: 34229314
    [No Abstract]   [Full Text] [Related]  

  • 9. A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication.
    Piech DK; Johnson BC; Shen K; Ghanbari MM; Li KY; Neely RM; Kay JE; Carmena JM; Maharbiz MM; Muller R
    Nat Biomed Eng; 2020 Feb; 4(2):207-222. PubMed ID: 32076132
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Wide Dynamic Range Neural Data Acquisition System With High-Precision Delta-Sigma ADC and On-Chip EC-PC Spike Processor.
    Xu J; Nguyen AT; Wu T; Zhao W; Luu DK; Yang Z
    IEEE Trans Biomed Circuits Syst; 2020 Jun; 14(3):425-440. PubMed ID: 32031949
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Recent progress on peripheral neural interface technology towards bioelectronic medicine.
    Cho Y; Park J; Lee C; Lee S
    Bioelectron Med; 2020 Nov; 6(1):23. PubMed ID: 33292861
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In Vivo Magnetic Stimulation of Rat Sciatic Nerve With Centimeter- and Millimeter-Scale Solenoid Coils.
    Kagan ZB; RamRakhyani AK; Lazzi G; Normann RA; Warren DJ
    IEEE Trans Neural Syst Rehabil Eng; 2016 Nov; 24(11):1138-1147. PubMed ID: 27019496
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A 3 mm × 3 mm Fully Integrated Wireless Power Receiver and Neural Interface System-on-Chip.
    Kim C; Park J; Ha S; Akinin A; Kubendran R; Mercier PP; Cauwenberghs G
    IEEE Trans Biomed Circuits Syst; 2019 Dec; 13(6):1736-1746. PubMed ID: 31581095
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fascicle specific targeting for selective peripheral nerve stimulation.
    Overstreet CK; Cheng J; Keefer EW
    J Neural Eng; 2019 Nov; 16(6):066040. PubMed ID: 31509815
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The PennBMBI: Design of a General Purpose Wireless Brain-Machine-Brain Interface System.
    Liu X; Zhang M; Subei B; Richardson AG; Lucas TH; Van der Spiegel J
    IEEE Trans Biomed Circuits Syst; 2015 Apr; 9(2):248-58. PubMed ID: 25769171
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A 110-nW in-channel sigma-delta converter for large-scale neural recording implants.
    Rezaei M; Maghsoudloo E; Sawan M; Gosselin B
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():5741-5744. PubMed ID: 28269558
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode.
    Shon A; Chu JU; Jung J; Kim H; Youn I
    Sensors (Basel); 2017 Dec; 18(1):. PubMed ID: 29267230
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Wirelessly Powered Scattered Neural Recording Wearable System.
    Han Y; Zhao L; Stephany RG; Hsieh JC; Wang H; Jia Y
    IEEE Trans Biomed Circuits Syst; 2024 May; PP():. PubMed ID: 38713579
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design of a Closed-Loop, Bidirectional Brain Machine Interface System With Energy Efficient Neural Feature Extraction and PID Control.
    Liu X; Zhang M; Richardson AG; Lucas TH; Van der Spiegel J
    IEEE Trans Biomed Circuits Syst; 2017 Aug; 11(4):729-742. PubMed ID: 28029630
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A wideband dual-antenna receiver for wireless recording from animals behaving in large arenas.
    Lee SB; Yin M; Manns JR; Ghovanloo M
    IEEE Trans Biomed Eng; 2013 Jul; 60(7):1993-2004. PubMed ID: 23428612
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.