207 related articles for article (PubMed ID: 37962088)
1. Left bundle branch pacing versus left ventricular septal pacing as a primary procedural endpoint during left bundle branch area pacing: Evaluation of two different implant strategies.
Cano Ó; Jover P; Ayala HD; Navarrete-Navarro J; Osca J; Izquierdo M; Navarro J; Martínez-Dolz L
J Cardiovasc Electrophysiol; 2024 Jan; 35(1):120-129. PubMed ID: 37962088
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing.
Wu S; Chen X; Wang S; Xu L; Xiao F; Huang Z; Zheng R; Jiang L; Vijayaraman P; Sharma PS; Su L; Huang W
JACC Clin Electrophysiol; 2021 Sep; 7(9):1166-1177. PubMed ID: 33933414
[TBL] [Abstract][Full Text] [Related]
3. Difference of ventricular synchrony between LBBP, LBFP and LVSP: A speckle tracking echocardiographic study.
Cheng C; Sun L; Peng X; Wang Y; Shi L; Zhao T; Wei Z; Tian Y; Liu X
J Interv Card Electrophysiol; 2024 Apr; 67(3):539-547. PubMed ID: 37574493
[TBL] [Abstract][Full Text] [Related]
4. New criterion to determine left bundle branch capture on the basis of individualized His bundle or right ventricular septal pacing.
Qian Z; Xue S; Zou F; Qin C; Wang Y; Zhang X; Qiu Y; Wu H; Hou X; Zou J
Heart Rhythm; 2022 Dec; 19(12):1984-1992. PubMed ID: 35932987
[TBL] [Abstract][Full Text] [Related]
5. Resynchronization effects and clinical outcomes during left bundle branch area pacing with and without conduction system capture.
Zhang W; Chen L; Zhou X; Huang J; Zhu S; Shen E; Pan C; Hou X; Li R; He B
Clin Cardiol; 2023 Mar; 46(3):287-295. PubMed ID: 36597668
[TBL] [Abstract][Full Text] [Related]
6. Is the pacing site closer to the left ventricular septal endocardium in left bundle branch pacing or in left ventricular septal pacing?
Peng XY; Wang YJ; Sun LL; Shi L; Cheng CD; Huang LH; Tian Y; Liu XP
J Interv Card Electrophysiol; 2023 Apr; 66(3):539-549. PubMed ID: 35146599
[TBL] [Abstract][Full Text] [Related]
7. Comparing Ventricular Synchrony in Left Bundle Branch and Left Ventricular Septal Pacing in Pacemaker Patients.
Heckman LIB; Luermans JGLM; Curila K; Van Stipdonk AMW; Westra S; Smisek R; Prinzen FW; Vernooy K
J Clin Med; 2021 Feb; 10(4):. PubMed ID: 33671420
[TBL] [Abstract][Full Text] [Related]
8. Differentiating left bundle branch pacing and left ventricular septal pacing: An algorithm based on intracardiac electrophysiology.
Chen X; Qian Z; Zou F; Wang Y; Zhang X; Qiu Y; Hou X; Zhou X; Vijayaraman P; Zou J
J Cardiovasc Electrophysiol; 2022 Mar; 33(3):448-457. PubMed ID: 34978368
[TBL] [Abstract][Full Text] [Related]
9. Redefining QRS transition to confirm left bundle branch capture during left bundle branch area pacing.
Briongos-Figuero S; Estévez Paniagua Á; Sánchez Hernández A; Muñoz-Aguilera R
Front Cardiovasc Med; 2023; 10():1217133. PubMed ID: 37522077
[TBL] [Abstract][Full Text] [Related]
10. Cardiac resynchronization therapy via left bundle branch pacing vs. optimized biventricular pacing with adaptive algorithm in heart failure with left bundle branch block: a prospective, multi-centre, observational study.
Chen X; Ye Y; Wang Z; Jin Q; Qiu Z; Wang J; Qin S; Bai J; Wang W; Liang Y; Chen H; Sheng X; Gao F; Zhao X; Fu G; Ellenbogen KA; Su Y; Ge J
Europace; 2022 May; 24(5):807-816. PubMed ID: 34718539
[TBL] [Abstract][Full Text] [Related]
11. Achievement rate and learning curve of left bundle branch capture in left bundle branch area pacing procedure performed to demonstrate output-dependent QRS transition.
Shimeno K; Tamura S; Hayashi Y; Abe Y; Naruko T; Fukuda D
J Cardiovasc Electrophysiol; 2022 Oct; 33(10):2183-2191. PubMed ID: 35842801
[TBL] [Abstract][Full Text] [Related]
12. Left bundle branch pacing compared to left ventricular septal myocardial pacing increases interventricular dyssynchrony but accelerates left ventricular lateral wall depolarization.
Curila K; Jurak P; Jastrzebski M; Prinzen F; Waldauf P; Halamek J; Vernooy K; Smisek R; Karch J; Plesinger F; Moskal P; Susankova M; Znojilova L; Heckman L; Viscor I; Vondra V; Leinveber P; Osmancik P
Heart Rhythm; 2021 Aug; 18(8):1281-1289. PubMed ID: 33930549
[TBL] [Abstract][Full Text] [Related]
13. Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center Study.
Su L; Wang S; Wu S; Xu L; Huang Z; Chen X; Zheng R; Jiang L; Ellenbogen KA; Whinnett ZI; Huang W
Circ Arrhythm Electrophysiol; 2021 Feb; 14(2):e009261. PubMed ID: 33426907
[TBL] [Abstract][Full Text] [Related]
14. Influence of Capture Selectivity and Left Intrahisian Block on QRS Characteristics During Left Bundle Branch Pacing.
Sun W; Upadhyay GA; Tung R
JACC Clin Electrophysiol; 2022 May; 8(5):635-647. PubMed ID: 35589176
[TBL] [Abstract][Full Text] [Related]
15. Electrophysiological Insights into Three Modalities of Left Bundle Branch Area Pacing in Patients Indicated for Pacing Therapy.
Zhang J; Sheng X; Pan Y; Wang M; Fu G
Int Heart J; 2021 Jan; 62(1):78-86. PubMed ID: 33390564
[TBL] [Abstract][Full Text] [Related]
16. Criteria for differentiating left bundle branch pacing and left ventricular septal pacing: A systematic review.
Zhu K; Li L; Liu J; Chang D; Li Q
Front Cardiovasc Med; 2022; 9():1006966. PubMed ID: 36247445
[TBL] [Abstract][Full Text] [Related]
17. Left bundle branch pacing vs ventricular septal pacing for cardiac resynchronization therapy.
Chen J; Ezzeddine FM; Liu X; Vaidya V; McLeod CJ; Valverde AM; Del-Carpio Munoz F; Deshmukh AJ; Madhavan M; Killu AM; Mulpuru SK; Friedman PA; Cha YM
Heart Rhythm O2; 2024 Mar; 5(3):150-157. PubMed ID: 38560374
[TBL] [Abstract][Full Text] [Related]
18. Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum.
Hou X; Qian Z; Wang Y; Qiu Y; Chen X; Jiang H; Jiang Z; Wu H; Zhao Z; Zhou W; Zou J
Europace; 2019 Nov; 21(11):1694-1702. PubMed ID: 31322651
[TBL] [Abstract][Full Text] [Related]
19. Left Bundle Branch Pacing for Cardiac Resynchronization Therapy: Nonrandomized On-Treatment Comparison With His Bundle Pacing and Biventricular Pacing.
Wu S; Su L; Vijayaraman P; Zheng R; Cai M; Xu L; Shi R; Huang Z; Whinnett ZI; Huang W
Can J Cardiol; 2021 Feb; 37(2):319-328. PubMed ID: 32387225
[TBL] [Abstract][Full Text] [Related]
20. An individualized criterion for left bundle branch capture in patients with a narrow QRS complex.
Li M; Li C; Li J; Yu H; Xu G; Gao Y; Xu B; Sun M; Wang Z; Han Y; Liang Y
Heart Rhythm; 2024 Mar; 21(3):294-300. PubMed ID: 37952864
[TBL] [Abstract][Full Text] [Related]