These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 3796482)

  • 1. A logit model for the modulation transfer function of screen-film systems.
    Bencomo JA; Fallone BG
    Med Phys; 1986; 13(6):857-60. PubMed ID: 3796482
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lubberts effect in columnar phosphors.
    Badano A; Gagne RM; Gallas BD; Jennings RJ; Boswell JS; Myers KJ
    Med Phys; 2004 Nov; 31(11):3122-31. PubMed ID: 15587665
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The energy-dependent behavior of noise Wiener spectra in their low-frequency limits: comparison with simple theory.
    Vyborny CJ; Loo LN; Doi K
    Radiology; 1982 Aug; 144(3):619-22. PubMed ID: 7100480
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Energy and angular dependence of x-ray absorption and its effect on radiographic response in screen--film systems.
    Chan HP; Doi K
    Phys Med Biol; 1983 May; 28(5):565-79. PubMed ID: 6867113
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Image quality parameters of film-screen systems].
    Hoeschen D
    Rontgenblatter; 1987 Jun; 40(6):193-9. PubMed ID: 3616429
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Measurement of the modulation transfer function of film-screen combinations with a lead scanning pattern].
    Hoeschen D; Mirandé W
    Rofo; 1984 May; 140(5):600-4. PubMed ID: 6429767
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-speed, single-screen/single-emulsion film systems: basic imaging properties and preliminary clinical applications.
    Higashida Y; Frank PH; Doi K
    Radiology; 1983 Nov; 149(2):571-7. PubMed ID: 6622705
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radiographic mottle: a comprehensive theory.
    Barnes GT
    Med Phys; 1982; 9(5):656-67. PubMed ID: 7155067
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Absolute speeds of screen-film systems and their absorbed-energy constants.
    Kodera Y; Doi K; Chan HP
    Radiology; 1984 Apr; 151(1):229-36. PubMed ID: 6701320
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wiener spectral effects of spatial correlation between the sites of characteristic x-ray emission and reabsorption in radiographic screen-film systems.
    Metz CE; Vyborny CJ
    Phys Med Biol; 1983 May; 28(5):547-64. PubMed ID: 6867112
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of radiographic image quality parameters obtained with the REX simulator.
    Magalhaes LA; Drexler GG; deAlmeida CE
    Radiat Prot Dosimetry; 2011 Nov; 147(4):614-8. PubMed ID: 21273198
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative evaluation of several rare-earth film-screen systems.
    Braun M; Wilson BC
    Radiology; 1982 Sep; 144(4):915-9. PubMed ID: 7111746
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Signal-to-noise properties of mammographic film-screen systems.
    Nishikawa RM; Yaffe MJ
    Med Phys; 1985; 12(1):32-9. PubMed ID: 3974523
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Film-screen digital radiography.
    Schwenker RP; Eger H
    Radiography; 1985; 51(598):233-5. PubMed ID: 4048409
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative assessment of a new dental imaging system.
    Walker A; Horner K; Czajka J; Shearer AC; Wilson NH
    Br J Radiol; 1991 Jun; 64(762):529-36. PubMed ID: 2070184
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Digital roentgenographic systems based on photostimulated screens and their comparison with roentgenographic screen-film sets].
    Gorelik FG; Stankevich NE
    Med Tekh; 2006; (5):10-3. PubMed ID: 17133936
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Wiener spectra of roentgen film-screen combinations].
    Mirandé W; Hoeschen D
    Rontgenblatter; 1985 Mar; 38(3):81-4. PubMed ID: 3992138
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual-film cassette technique for studying the effect of radiographic image quality on diagnostic accuracy.
    Higashida Y; Doi K; Lehr JL; MacMahon H
    Med Phys; 1984; 11(5):646-52. PubMed ID: 6503880
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Modification of the quality of the roentgen image by screen and film--experimental studies].
    Maurer HJ; Goos F
    Rontgenblatter; 1985 Feb; 38(2):54-7. PubMed ID: 3983537
    [No Abstract]   [Full Text] [Related]  

  • 20. [Characteristics of screen-film systems for mammography in relation to a diverse modality of treatment].
    Rosselli Del Turco M; Milano F; Giani M; Bravetti P
    Radiol Med; 1988 Apr; 75(4):390-4. PubMed ID: 3375482
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.