These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 37975638)

  • 1. Relationship between imaging parameters and distortion in magnetic resonance images for gamma knife treatment planning.
    Koori N; Kamekawa H; Mukawa N; Fuse H; Miyakawa S; Yasue K; Takahashi M; Yamada M; Henmi A; Kusumoto T; Kurata K
    J Appl Clin Med Phys; 2023 Dec; 24(12):e14205. PubMed ID: 37975638
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of system-related geometric distortions in MR images employed in Gamma Knife radiosurgery applications.
    Pappas EP; Seimenis I; Moutsatsos A; Georgiou E; Nomikos P; Karaiskos P
    Phys Med Biol; 2016 Oct; 61(19):6993-7011. PubMed ID: 27648985
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Geometric distortion assessment in 3T MR images used for treatment planning in cranial Stereotactic Radiosurgery and Radiotherapy.
    Theocharis S; Pappas EP; Seimenis I; Kouris P; Dellios D; Kollias G; Karaiskos P
    PLoS One; 2022; 17(5):e0268925. PubMed ID: 35605005
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Image distortion in MRI-based polymer gel dosimetry of gamma knife stereotactic radiosurgery systems.
    Watanabe Y; Perera GM; Mooij RB
    Med Phys; 2002 May; 29(5):797-802. PubMed ID: 12033575
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Distortion of magnetic resonance images used in gamma knife radiosurgery treatment planning: implications for acoustic neuroma outcomes.
    Poetker DM; Jursinic PA; Runge-Samuelson CL; Wackym PA
    Otol Neurotol; 2005 Nov; 26(6):1220-8. PubMed ID: 16272946
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical impact of magnetic resonance imaging distortions on gamma knife radiosurgery.
    Jacobson S; Jones C; Lusk R; Jenkins M; Chamunyonga C; Pinkham MB; Brown E
    J Med Radiat Sci; 2021 Sep; 68(3):274-281. PubMed ID: 33942565
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous table acquisition MRI for radiotherapy treatment planning: distortion assessment with a new extended 3D volumetric phantom.
    Walker A; Liney G; Holloway L; Dowling J; Rivest-Henault D; Metcalfe P
    Med Phys; 2015 Apr; 42(4):1982-91. PubMed ID: 25832089
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Distortion inherent to magnetic resonance imaging can lead to geometric miss in radiosurgery planning.
    Seibert TM; White NS; Kim GY; Moiseenko V; McDonald CR; Farid N; Bartsch H; Kuperman J; Karunamuni R; Marshall D; Holland D; Sanghvi P; Simpson DR; Mundt AJ; Dale AM; Hattangadi-Gluth JA
    Pract Radiat Oncol; 2016; 6(6):e319-e328. PubMed ID: 27523440
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Minimizing magnetic resonance image geometric distortion at 7 Tesla for frameless presurgical planning using skin-adhered fiducials.
    Kirby KM; Koons EK; Welker KM; Fagan AJ
    Med Phys; 2023 Feb; 50(2):694-701. PubMed ID: 36301228
    [TBL] [Abstract][Full Text] [Related]  

  • 10. MRI distortion: considerations for MRI based radiotherapy treatment planning.
    Walker A; Liney G; Metcalfe P; Holloway L
    Australas Phys Eng Sci Med; 2014 Mar; 37(1):103-13. PubMed ID: 24519001
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of sequence dependent geometric distortion in contrast-enhanced MR images employed in stereotactic radiosurgery treatment planning.
    Pappas EP; Seimenis I; Dellios D; Kollias G; Lampropoulos KI; Karaiskos P
    Phys Med Biol; 2018 Jun; 63(13):135006. PubMed ID: 29794347
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Geometric distortions in clinical MRI sequences for radiotherapy: insights gained from a multicenter investigation.
    Hasler SW; Kallehauge JF; Hansen RH; Samsøe E; Arp DT; Nissen HD; Edmund JM; Bernchou U; Mahmood F
    Acta Oncol; 2023 Nov; 62(11):1551-1560. PubMed ID: 37815867
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Geometric inaccuracy and co-registration errors for CT, DynaCT and MRI images used in robotic stereotactic radiosurgery treatment planning.
    Aldosary G; Szanto J; Holmes O; Lavigne B; Althobaity W; Sheikh A; Foottit C; Vandervoort E
    Phys Med; 2020 Jan; 69():212-222. PubMed ID: 31918373
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of MRI image distortion based on 6 consecutive years of annual QAs and measurements on 14 MRI scanners used for radiation therapy.
    Lu L; Yang X; Raterman B; Jiang X; Meineke M; Grecula J; Blakaj D; Palmer J; Raval R; Thomas E; Hintenlang D; Gupta N
    J Appl Clin Med Phys; 2023 Jan; 24(1):e13843. PubMed ID: 36385457
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Skull phantom-based methodology to validate MRI co-registration accuracy for Gamma Knife radiosurgery.
    Oglesby RT; Lam WW; Ruschin M; Holden L; Sarfehnia A; Yeboah C; Sahgal A; Soliman H; Detsky J; Tseng CL; Myrehaug S; Husain Z; Lau AZ; Stanisz GJ; Chugh BP
    Med Phys; 2022 Nov; 49(11):7071-7084. PubMed ID: 35842918
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The possibility of the use of MRI images in the three-dimensional external radiotherapy treatment planning].
    Major T; Petrányi A; Varjas G; Németh G
    Magy Onkol; 2002; 46(3):239-45. PubMed ID: 12368919
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI.
    Schad LR; Bock M; Baudendistel K; Essig M; Debus J; Knopp MV; Engenhart R; Lorenz WJ
    Eur Radiol; 1996; 6(1):38-45. PubMed ID: 8797948
    [TBL] [Abstract][Full Text] [Related]  

  • 18. System-dependent image distortion related to gantry positions of a 0.35 T MRgRT: Characterization and the corresponding correction.
    Marasini S; Quinn B; Cole M; Flores R; Kim T
    J Appl Clin Med Phys; 2023 Jan; 24(1):e13826. PubMed ID: 36354747
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Gamma Knife
    Duggar WN; Morris B; Fatemi A; Bonds J; He R; Kanakamedala M; Rey-Dios R; Vijayakumar S; Yang C
    J Appl Clin Med Phys; 2019 Nov; 20(11):95-103. PubMed ID: 31587520
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Image distortion and artifacts caused by the use of a titanium aneurism clip in 1.5 tesla- and 3 tesla-magnetic resonance imaging: effect on 60cobalt stereotactic radiosurgery treatment planning].
    Nakazawa H; Yamamuro O; Uchiyama Y; Komori M
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Jun; 70(6):534-41. PubMed ID: 24953318
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.