These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 37978965)

  • 1. Efficacy of Pulsed Field vs Radiofrequency for the Reablation of Chronic Radiofrequency Ablation Substrate: Redo Pulsed Field Ablation.
    Younis A; Buck E; Santangeli P; Tabaja C; Garrott K; Lehn L; Hussein AA; Nakhla S; Nakagawa H; Yavin HD; Kanj M; Sroubek J; Saliba WI; Wazni OM
    JACC Clin Electrophysiol; 2024 Feb; 10(2):222-234. PubMed ID: 37978965
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulsed field ablation for pulmonary vein isolation: Preclinical safety and effectiveness of a novel hexaspline ablation catheter.
    Yu F; Dong X; Ding L; Reddy V; Tang M
    J Cardiovasc Electrophysiol; 2023 Nov; 34(11):2195-2202. PubMed ID: 37712346
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pulsed Field Ablation Using a Lattice Electrode for Focal Energy Delivery: Biophysical Characterization, Lesion Durability, and Safety Evaluation.
    Yavin H; Shapira-Daniels A; Barkagan M; Sroubek J; Shim D; Melidone R; Anter E
    Circ Arrhythm Electrophysiol; 2020 Jun; 13(6):e008580. PubMed ID: 32372696
    [TBL] [Abstract][Full Text] [Related]  

  • 4. How does the level of pulmonary venous isolation compare between pulsed field ablation and thermal energy ablation (radiofrequency, cryo, or laser)?
    Kawamura I; Neuzil P; Shivamurthy P; Kuroki K; Lam J; Musikantow D; Chu E; Turagam MK; Minami K; Funasako M; Petru J; Choudry S; Miller MA; Langan MN; Whang W; Dukkipati SR; Koruth JS; Reddy VY
    Europace; 2021 Nov; 23(11):1757-1766. PubMed ID: 34151947
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Point-by-Point Pulsed Field Ablation Using a Multimodality Generator and a Contact Force-Sensing Ablation Catheter: Comparison With Radiofrequency Ablation in a Remapped Chronic Swine Heart.
    Di Biase L; Marazzato J; Zou F; Lin A; Grupposo V; Chowdhuri N; Maffre J; Farshchi-Heydari S; Sharma T; Beeckler C; Govari A; Bhardwaj R; Mohanty S; Natale A; Nakagawa H; Zhang X
    Circ Arrhythm Electrophysiol; 2023 Dec; 16(12):663-671. PubMed ID: 37994554
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intracardiac pulsed field ablation: Proof of feasibility in a chronic porcine model.
    Stewart MT; Haines DE; Verma A; Kirchhof N; Barka N; Grassl E; Howard B
    Heart Rhythm; 2019 May; 16(5):754-764. PubMed ID: 30385383
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of Pulsed-Field and Radiofrequency Ablation on Heterogeneous Ventricular Scar in a Swine Model of Healed Myocardial Infarction.
    Younis A; Zilberman I; Krywanczyk A; Higuchi K; Yavin HD; Sroubek J; Anter E
    Circ Arrhythm Electrophysiol; 2022 Oct; 15(10):e011209. PubMed ID: 36194542
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulsed Field Ablation Versus Radiofrequency Ablation: Esophageal Injury in a Novel Porcine Model.
    Koruth JS; Kuroki K; Kawamura I; Brose R; Viswanathan R; Buck ED; Donskoy E; Neuzil P; Dukkipati SR; Reddy VY
    Circ Arrhythm Electrophysiol; 2020 Mar; 13(3):e008303. PubMed ID: 31977250
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pulsed Field Ablation of Left Ventricular Myocardium in a Swine Infarct Model.
    Im SI; Higuchi S; Lee A; Stillson C; Buck E; Morrow B; Schenider K; Speltz M; Gerstenfeld EP
    JACC Clin Electrophysiol; 2022 Jun; 8(6):722-731. PubMed ID: 35738848
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulsed-field vs. cryoballoon vs. radiofrequency ablation: a propensity score matched comparison of one-year outcomes after pulmonary vein isolation in patients with paroxysmal atrial fibrillation.
    Maurhofer J; Kueffer T; Madaffari A; Stettler R; Stefanova A; Seiler J; Thalmann G; Kozhuharov N; Galuszka O; Servatius H; Haeberlin A; Noti F; Tanner H; Roten L; Reichlin T
    J Interv Card Electrophysiol; 2024 Mar; 67(2):389-397. PubMed ID: 37776355
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Focal Ablation Catheter Toggling Between Radiofrequency and Pulsed Field Energy to Treat Atrial Fibrillation.
    Reddy VY; Peichl P; Anter E; Rackauskas G; Petru J; Funasako M; Minami K; Koruth JS; Natale A; Jais P; Marinskis G; Aidietis A; Kautzner J; Neuzil P
    JACC Clin Electrophysiol; 2023 Aug; 9(8 Pt 3):1786-1801. PubMed ID: 37227340
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Acute lesion extension following pulmonary vein isolation with two novel single shot devices: Pulsed field ablation versus multielectrode radiofrequency balloon.
    My I; Lemoine MD; Butt M; Mencke C; Loeck FW; Obergassel J; Rottner L; Wenzel JP; Schleberger R; Moser J; Moser F; Kirchhof P; Reissmann B; Ouyang F; Rillig A; Metzner A
    J Cardiovasc Electrophysiol; 2023 Sep; 34(9):1802-1807. PubMed ID: 37473404
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Coronary Artery Spasm During Pulsed Field vs Radiofrequency Catheter Ablation of the Mitral Isthmus.
    Zhang C; Neuzil P; Petru J; Funasako M; Hala P; Kopriva K; Koruth JS; Dukkipati SR; Reddy VY
    JAMA Cardiol; 2024 Jan; 9(1):72-77. PubMed ID: 38019505
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of pulsed-field ablation versus very high power short duration-ablation for pulmonary vein isolation.
    Wörmann J; Schipper JH; Lüker J; van den Bruck JH; Filipovic K; Erlhöfer S; Pavel F; Scheurlen C; Dittrich S; Steven D; Sultan A
    J Cardiovasc Electrophysiol; 2023 Dec; 34(12):2417-2424. PubMed ID: 37846194
    [TBL] [Abstract][Full Text] [Related]  

  • 15. PV Isolation Using a Spherical Array PFA Catheter: Preclinical Assessment and Comparison to Radiofrequency Ablation.
    Koruth J; Verma A; Kawamura I; Reinders D; Andrade JG; Deyell MW; Mehta N; Reddy VY
    JACC Clin Electrophysiol; 2023 May; 9(5):652-666. PubMed ID: 36842871
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lesion formation following pulsed field ablation for pulmonary vein and posterior wall isolation.
    Sohns C; Fink T; Braun M; Sciacca V; Piran M; Khalaph M; Hamriti ME; Guckel D; Imnadze G; Sommer P
    Pacing Clin Electrophysiol; 2023 Jul; 46(7):714-716. PubMed ID: 37247251
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pulsed electric field, cryoballoon, and radiofrequency for paroxysmal atrial fibrillation ablation: a propensity score-matched comparison.
    Della Rocca DG; Marcon L; Magnocavallo M; Menè R; Pannone L; Mohanty S; Sousonis V; Sorgente A; Almorad A; Bisignani A; Głowniak A; Del Monte A; Bala G; Polselli M; Mouram S; La Fazia VF; Ströker E; Gianni C; Zeriouh S; Bianchi S; Sieira J; Combes S; Sarkozy A; Rossi P; Boveda S; Natale A; de Asmundis C; Chierchia GB;
    Europace; 2023 Dec; 26(1):. PubMed ID: 38245007
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel contact force sensing pulsed field ablation catheter in a porcine model.
    Hua J; Xiong Q; Kong Q; Xiong L; Huang Q; Hu J; Li J; Hu J; Si P; Zhou T; Chen Q
    Clin Cardiol; 2024 Feb; 47(2):e24220. PubMed ID: 38402563
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterization of circumferential antral pulmonary vein isolation areas resulting from pulsed-field catheter ablation.
    Bohnen M; Weber R; Minners J; Jadidi A; Eichenlaub M; Neumann FJ; Arentz T; Lehrmann H
    Europace; 2023 Feb; 25(1):65-73. PubMed ID: 35852306
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validation of a multipolar pulsed-field ablation catheter for endpoint assessment in pulmonary vein isolation procedures.
    Kueffer T; Baldinger SH; Servatius H; Madaffari A; Seiler J; Mühl A; Franzeck F; Thalmann G; Asatryan B; Haeberlin A; Noti F; Tanner H; Roten L; Reichlin T
    Europace; 2022 Sep; 24(8):1248-1255. PubMed ID: 35699395
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.