These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
145 related articles for article (PubMed ID: 37981629)
1. LAMS use in malignant stricture of duodenal apex with synchronous malignant biliary obstruction: a potentially effective and simpler endoscopic approach. Mai HD; Panicker L; Stone JJ; Brahmbhatt MN Clin J Gastroenterol; 2024 Feb; 17(1):52-56. PubMed ID: 37981629 [TBL] [Abstract][Full Text] [Related]
2. EUS-guided choledochoduodenostomy with lumen-apposing metal stent after failed rendezvous in synchronous malignant biliary and gastric outlet obstruction (with video). Perez-Miranda M; De la Serna Higuera C; Gil-Simon P; Hernandez V; Diez-Redondo P; Fernandez-Salazar L Gastrointest Endosc; 2014 Aug; 80(2):342; discussion 343-4. PubMed ID: 24814773 [No Abstract] [Full Text] [Related]
3. EUS-guided biliary drainage with LAMS for distal malignant biliary obstruction when ERCP fails: single-center retrospective study and maldeployment management. Di Mitri R; Amata M; Mocciaro F; Conte E; Bonaccorso A; Scrivo B; Scimeca D Surg Endosc; 2022 Jun; 36(6):4553-4569. PubMed ID: 34724586 [TBL] [Abstract][Full Text] [Related]
4. Endoscopic Ultrasound Guided Choledocho-Enterostomy by Using Lumen Apposing Metal Stent in Patients with Failed Endoscopic Retrograde Cholangiopancreatography: A Literature Review. Jain D; Shah M; Patel U; Sharma A; Singhal S Digestion; 2018; 98(1):1-10. PubMed ID: 29672294 [TBL] [Abstract][Full Text] [Related]
5. Clinical outcome of simultaneous self-expandable metal stents for palliation of malignant biliary and duodenal obstruction. Kaw M; Singh S; Gagneja H Surg Endosc; 2003 Mar; 17(3):457-61. PubMed ID: 12404053 [TBL] [Abstract][Full Text] [Related]
6. Advanced Endoscopic Techniques for the Diagnosis of Pancreatic Cancer and Management of Biliary and GastricOutlet Obstruction. Nakai Y; Smith Z; Chang KJ; Dua KS Surg Oncol Clin N Am; 2021 Oct; 30(4):639-656. PubMed ID: 34511187 [TBL] [Abstract][Full Text] [Related]
7. How to treat intestinal obstruction due to malignant recurrence after Whipple's resection for pancreatic head cancer: Description of 2 new endoscopic techniques. Mouradides C; Taha A; Borbath I; Deprez PH; Moreels TG World J Gastroenterol; 2017 Sep; 23(33):6181-6186. PubMed ID: 28970734 [TBL] [Abstract][Full Text] [Related]
8. Lumen apposing metal stents versus tubular self-expandable metal stents for endoscopic ultrasound-guided choledochoduodenostomy in malignant biliary obstruction. de Benito Sanz M; Nájera-Muñoz R; de la Serna-Higuera C; Fuentes-Valenzuela E; Fanjul I; Chavarría C; García-Alonso FJ; Sanchez-Ocana R; Carbajo AY; Bazaga S; Perez-Miranda M Surg Endosc; 2021 Dec; 35(12):6754-6762. PubMed ID: 33258038 [TBL] [Abstract][Full Text] [Related]
9. Cholecystoduodenostomy and duodenal stenting for relief of biliary and gastric outlet obstruction. Law R; Grimm IS; Baron TH Gastrointest Endosc; 2015 May; 81(5):1257-8. PubMed ID: 25440674 [No Abstract] [Full Text] [Related]
10. Combined Endoscopic Stent-In-Stent Placement by Lumen-Apposing Metal Stents Through Self-Expanding Metal Stents for Simultaneous Malignant Biliary and Duodenal Obstruction. Metelli F; Pezzoli A; Fabbri C; Pizzo E; Arena R; Cifalà V; Simone L; Solimando R; Merighi A ACG Case Rep J; 2021 Nov; 8(11):e00704. PubMed ID: 34841002 [TBL] [Abstract][Full Text] [Related]
11. EUS-guided gastroenterostomy using a novel electrocautery lumen apposing metal stent for treatment of gastric outlet obstruction (with video). Mangiavillano B; Larghi A; Vargas-Madrigal J; Facciorusso A; Di Matteo F; Crinò SF; Pham KD; Moon JH; Auriemma F; Camellini L; Paduano D; Stigliano S; Calabrese F; Ofosu A; Al-Lehibi A; Repici A Dig Liver Dis; 2023 May; 55(5):644-648. PubMed ID: 36890050 [TBL] [Abstract][Full Text] [Related]
12. Gastrojejunostomy versus endoscopic duodenal stent placement for gastric outlet obstruction in patients with unresectable pancreatic cancer: a propensity score-matched analysis. Tamura T; Mamoru T; Terai T; Ogura T; Tani M; Shimokawa T; Kitahata Y; Matsumoto I; Mitoro A; Asakuma M; Inatomi O; Omoto S; Sho M; Ueno S; Maehira H; Kitano M Surg Endosc; 2023 Mar; 37(3):1890-1900. PubMed ID: 36258002 [TBL] [Abstract][Full Text] [Related]
13. An unusual complication of pyloric ring obstruction caused by flange of lumen apposing metal stent in endoscopic ultrasound-guided gallbladder drainage: A case report. Seo SY; Lee CH; Kim IH; Kim SW; Lee SO; Lee ST; Kim SH Medicine (Baltimore); 2020 Jul; 99(27):e21017. PubMed ID: 32629723 [TBL] [Abstract][Full Text] [Related]
14. Lumen-apposing metal stent for treatment of malignant biliary obstruction, placed through an uncovered duodenal self-expanding metal stent. Due-Petersson R; Hansen LB BMJ Case Rep; 2021 Apr; 14(4):. PubMed ID: 33858881 [TBL] [Abstract][Full Text] [Related]
15. Effectiveness of combined biliary and duodenal stenting in patients with malignant biliary and duodenal obstruction. Kim KO; Kim TN; Lee HC Scand J Gastroenterol; 2012 Sep; 47(8-9):962-7. PubMed ID: 22571283 [TBL] [Abstract][Full Text] [Related]
16. Success and safety of endoscopic treatments for concomitant biliary and duodenal malignant stenosis: A review of the literature. Mangiavillano B; Khashab MA; Tarantino I; Carrara S; Semeraro R; Auriemma F; Bianchetti M; Eusebi LH; Yen-I C; De Luca L; Traina M; Repici A World J Gastrointest Surg; 2019 Feb; 11(2):53-61. PubMed ID: 30842812 [TBL] [Abstract][Full Text] [Related]
17. Hybrid gastroenterostomy using a lumen-apposing metal stent: a case report focusing on misdeployment and systematic review of the current literature. Fabbri C; Binda C; Fugazzola P; Sbrancia M; Tomasoni M; Coluccio C; Jung CFM; Prosperi E; Agnoletti V; Ansaloni L World J Emerg Surg; 2022 Jan; 17(1):6. PubMed ID: 35065661 [TBL] [Abstract][Full Text] [Related]
18. EUS-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent placement should replace PTBD after ERCP failure in patients with distal tumoral biliary obstruction: a large real-life study. Ginestet C; Sanglier F; Hummel V; Rouchaud A; Legros R; Lepetit H; Dahan M; Carrier P; Loustaud-Ratti V; Sautereau D; Albouys J; Jacques J; Geyl S Surg Endosc; 2022 May; 36(5):3365-3373. PubMed ID: 34606007 [TBL] [Abstract][Full Text] [Related]
19. Palliation of malignant gastric outlet obstruction with simultaneous endoscopic insertion of afferent and efferent jejunal limb enteral stents in patients with recurrent malignancy. Soo I; Gerdes H; Markowitz AJ; Mendelsohn RB; Ludwig E; Shah P; Schattner MA Surg Endosc; 2016 Feb; 30(2):521-525. PubMed ID: 26091983 [TBL] [Abstract][Full Text] [Related]
20. ERCP performed through previously placed duodenal stents: a multicenter retrospective study of outcomes and adverse events. Staub J; Siddiqui A; Taylor LJ; Loren D; Kowalski T; Adler DG Gastrointest Endosc; 2018 Jun; 87(6):1499-1504. PubMed ID: 29425886 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]