BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 37981629)

  • 1. LAMS use in malignant stricture of duodenal apex with synchronous malignant biliary obstruction: a potentially effective and simpler endoscopic approach.
    Mai HD; Panicker L; Stone JJ; Brahmbhatt MN
    Clin J Gastroenterol; 2024 Feb; 17(1):52-56. PubMed ID: 37981629
    [TBL] [Abstract][Full Text] [Related]  

  • 2. EUS-guided choledochoduodenostomy with lumen-apposing metal stent after failed rendezvous in synchronous malignant biliary and gastric outlet obstruction (with video).
    Perez-Miranda M; De la Serna Higuera C; Gil-Simon P; Hernandez V; Diez-Redondo P; Fernandez-Salazar L
    Gastrointest Endosc; 2014 Aug; 80(2):342; discussion 343-4. PubMed ID: 24814773
    [No Abstract]   [Full Text] [Related]  

  • 3. EUS-guided biliary drainage with LAMS for distal malignant biliary obstruction when ERCP fails: single-center retrospective study and maldeployment management.
    Di Mitri R; Amata M; Mocciaro F; Conte E; Bonaccorso A; Scrivo B; Scimeca D
    Surg Endosc; 2022 Jun; 36(6):4553-4569. PubMed ID: 34724586
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Endoscopic Ultrasound Guided Choledocho-Enterostomy by Using Lumen Apposing Metal Stent in Patients with Failed Endoscopic Retrograde Cholangiopancreatography: A Literature Review.
    Jain D; Shah M; Patel U; Sharma A; Singhal S
    Digestion; 2018; 98(1):1-10. PubMed ID: 29672294
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical outcome of simultaneous self-expandable metal stents for palliation of malignant biliary and duodenal obstruction.
    Kaw M; Singh S; Gagneja H
    Surg Endosc; 2003 Mar; 17(3):457-61. PubMed ID: 12404053
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Advanced Endoscopic Techniques for the Diagnosis of Pancreatic Cancer and Management of Biliary and GastricOutlet Obstruction.
    Nakai Y; Smith Z; Chang KJ; Dua KS
    Surg Oncol Clin N Am; 2021 Oct; 30(4):639-656. PubMed ID: 34511187
    [TBL] [Abstract][Full Text] [Related]  

  • 7. How to treat intestinal obstruction due to malignant recurrence after Whipple's resection for pancreatic head cancer: Description of 2 new endoscopic techniques.
    Mouradides C; Taha A; Borbath I; Deprez PH; Moreels TG
    World J Gastroenterol; 2017 Sep; 23(33):6181-6186. PubMed ID: 28970734
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lumen apposing metal stents versus tubular self-expandable metal stents for endoscopic ultrasound-guided choledochoduodenostomy in malignant biliary obstruction.
    de Benito Sanz M; Nájera-Muñoz R; de la Serna-Higuera C; Fuentes-Valenzuela E; Fanjul I; Chavarría C; García-Alonso FJ; Sanchez-Ocana R; Carbajo AY; Bazaga S; Perez-Miranda M
    Surg Endosc; 2021 Dec; 35(12):6754-6762. PubMed ID: 33258038
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cholecystoduodenostomy and duodenal stenting for relief of biliary and gastric outlet obstruction.
    Law R; Grimm IS; Baron TH
    Gastrointest Endosc; 2015 May; 81(5):1257-8. PubMed ID: 25440674
    [No Abstract]   [Full Text] [Related]  

  • 10. Combined Endoscopic Stent-In-Stent Placement by Lumen-Apposing Metal Stents Through Self-Expanding Metal Stents for Simultaneous Malignant Biliary and Duodenal Obstruction.
    Metelli F; Pezzoli A; Fabbri C; Pizzo E; Arena R; Cifalà V; Simone L; Solimando R; Merighi A
    ACG Case Rep J; 2021 Nov; 8(11):e00704. PubMed ID: 34841002
    [TBL] [Abstract][Full Text] [Related]  

  • 11. EUS-guided gastroenterostomy using a novel electrocautery lumen apposing metal stent for treatment of gastric outlet obstruction (with video).
    Mangiavillano B; Larghi A; Vargas-Madrigal J; Facciorusso A; Di Matteo F; Crinò SF; Pham KD; Moon JH; Auriemma F; Camellini L; Paduano D; Stigliano S; Calabrese F; Ofosu A; Al-Lehibi A; Repici A
    Dig Liver Dis; 2023 May; 55(5):644-648. PubMed ID: 36890050
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gastrojejunostomy versus endoscopic duodenal stent placement for gastric outlet obstruction in patients with unresectable pancreatic cancer: a propensity score-matched analysis.
    Tamura T; Mamoru T; Terai T; Ogura T; Tani M; Shimokawa T; Kitahata Y; Matsumoto I; Mitoro A; Asakuma M; Inatomi O; Omoto S; Sho M; Ueno S; Maehira H; Kitano M
    Surg Endosc; 2023 Mar; 37(3):1890-1900. PubMed ID: 36258002
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An unusual complication of pyloric ring obstruction caused by flange of lumen apposing metal stent in endoscopic ultrasound-guided gallbladder drainage: A case report.
    Seo SY; Lee CH; Kim IH; Kim SW; Lee SO; Lee ST; Kim SH
    Medicine (Baltimore); 2020 Jul; 99(27):e21017. PubMed ID: 32629723
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lumen-apposing metal stent for treatment of malignant biliary obstruction, placed through an uncovered duodenal self-expanding metal stent.
    Due-Petersson R; Hansen LB
    BMJ Case Rep; 2021 Apr; 14(4):. PubMed ID: 33858881
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effectiveness of combined biliary and duodenal stenting in patients with malignant biliary and duodenal obstruction.
    Kim KO; Kim TN; Lee HC
    Scand J Gastroenterol; 2012 Sep; 47(8-9):962-7. PubMed ID: 22571283
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Success and safety of endoscopic treatments for concomitant biliary and duodenal malignant stenosis: A review of the literature.
    Mangiavillano B; Khashab MA; Tarantino I; Carrara S; Semeraro R; Auriemma F; Bianchetti M; Eusebi LH; Yen-I C; De Luca L; Traina M; Repici A
    World J Gastrointest Surg; 2019 Feb; 11(2):53-61. PubMed ID: 30842812
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hybrid gastroenterostomy using a lumen-apposing metal stent: a case report focusing on misdeployment and systematic review of the current literature.
    Fabbri C; Binda C; Fugazzola P; Sbrancia M; Tomasoni M; Coluccio C; Jung CFM; Prosperi E; Agnoletti V; Ansaloni L
    World J Emerg Surg; 2022 Jan; 17(1):6. PubMed ID: 35065661
    [TBL] [Abstract][Full Text] [Related]  

  • 18. EUS-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent placement should replace PTBD after ERCP failure in patients with distal tumoral biliary obstruction: a large real-life study.
    Ginestet C; Sanglier F; Hummel V; Rouchaud A; Legros R; Lepetit H; Dahan M; Carrier P; Loustaud-Ratti V; Sautereau D; Albouys J; Jacques J; Geyl S
    Surg Endosc; 2022 May; 36(5):3365-3373. PubMed ID: 34606007
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Palliation of malignant gastric outlet obstruction with simultaneous endoscopic insertion of afferent and efferent jejunal limb enteral stents in patients with recurrent malignancy.
    Soo I; Gerdes H; Markowitz AJ; Mendelsohn RB; Ludwig E; Shah P; Schattner MA
    Surg Endosc; 2016 Feb; 30(2):521-525. PubMed ID: 26091983
    [TBL] [Abstract][Full Text] [Related]  

  • 20. ERCP performed through previously placed duodenal stents: a multicenter retrospective study of outcomes and adverse events.
    Staub J; Siddiqui A; Taylor LJ; Loren D; Kowalski T; Adler DG
    Gastrointest Endosc; 2018 Jun; 87(6):1499-1504. PubMed ID: 29425886
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.