These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 37993320)

  • 21. Fabrication of obturator prosthesis by fusing CBCT and digital impression data.
    Murat S; Gürbüz A; Kamburoğlu K
    Int J Comput Dent; 2018; 21(4):335-344. PubMed ID: 30539176
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A modified technique to fabricate a complete hollow obturator for bilateral maxillectomy in a patient with mucormycosis-A technical case report.
    Mani UM; Mohamed K; Krishna Kumar A; Inbarajan A
    Spec Care Dentist; 2019 Nov; 39(6):610-616. PubMed ID: 31608482
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fabrication of a hollow obturator as a single unit for management of bilateral subtotal maxillectomy.
    Patil PG; Patil SP
    J Prosthodont; 2012 Apr; 21(3):194-9. PubMed ID: 22372720
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A two-step (altered cast) impression technique in the prosthetic rehabilitation of a patient after a maxillectomy: a clinical report.
    Vojvodic D; Kranjcic J
    J Prosthet Dent; 2013 Sep; 110(3):228-31. PubMed ID: 24029612
    [TBL] [Abstract][Full Text] [Related]  

  • 25. CAD-CAM Hollow Obturator Prosthesis: A Technical Report.
    Alfaraj A; Su FY; Lin WS
    J Prosthodont; 2022 Aug; 31(7):635-638. PubMed ID: 35343606
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Generation and evaluation of 3D digital casts of maxillary defects based on multisource data registration: A pilot clinical study.
    Ye H; Ma Q; Hou Y; Li M; Zhou Y
    J Prosthet Dent; 2017 Dec; 118(6):790-795. PubMed ID: 28449864
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Maxillary hollow-bulb obturator: A paradigm shift.
    Punjabi AR; Mistry G; Shetty O; Rathod A
    J Indian Prosthodont Soc; 2019; 19(1):74-78. PubMed ID: 30745757
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Fabrication of a 3-dimensionally printed definitive cast for an obturator prosthesis by merging intraoral scan image with cone beam computed tomography data: A clinical report.
    Murat S; Batak B
    J Prosthet Dent; 2021 Aug; 126(2):256.e1-256.e4. PubMed ID: 33309209
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An alternative procedure for fabricating a hollow interim obturator for a partial maxillectomy patient.
    Shimizu H; Yoshida K; Mori N; Takahashi Y
    J Prosthodont; 2009 Apr; 18(3):276-8. PubMed ID: 19141042
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Rehabilitation of Oncology Patients with Hard Palate Defects Part 3: Construction of an Acrylic Hollow Box Obturator.
    Ali R; Altaie A; Nattress B
    Dent Update; 2015 Sep; 42(7):612-4, 616, 618-20. PubMed ID: 26630859
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Light is right-various techniques to fabricate hollow obturators.
    Nanda A; Jain V; Nafria A
    Cleft Palate Craniofac J; 2013 Mar; 50(2):237-41. PubMed ID: 22126446
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Fully integrated additive manufacturing of an obturator prosthesis for an edentulous patient with a maxillectomy defect.
    Zhang T; Zheng Y; Zhong S; Bai S
    J Prosthet Dent; 2024 Jun; ():. PubMed ID: 38942715
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Obturator fabrication incorporating computer-aided design and 3-dimensional printing technology: A clinical report.
    Soltanzadeh P; Su JM; Habibabadi SR; Kattadiyil MT
    J Prosthet Dent; 2019 Apr; 121(4):694-697. PubMed ID: 30711293
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Reverse scan body: A complete digital workflow for prosthesis prototype fabrication.
    Papaspyridakos P; Bedrossian A; Kudara Y; Ntovas P; Bokhary A; Chochlidakis K
    J Prosthodont; 2023 Jun; 32(5):452-457. PubMed ID: 36779654
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Rehabilitation of a maxillectomy case with telescopic crowns: a case report.
    Sethuram AK; Sahoo N; Sandhu H; Radhakrishnan V
    J Indian Prosthodont Soc; 2013 Sep; 13(3):236-9. PubMed ID: 24431740
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Complete Digital Workflow for Prosthesis Prototype Fabrication with Double Digital Scanning: Accuracy of Fit Assessment.
    Papaspyridakos P; AlFulaij F; Bokhary A; Sallustio A; Chochlidakis K
    J Prosthodont; 2023 Jan; 32(1):49-53. PubMed ID: 35176178
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A method of hollowing the obturator prosthesis and an overview on the pros and cons of the various materials used for hollowing.
    Nimonkar SV; Belkhode VM; Asiri AM; Aldossary MF; Nimonkar PV
    J Med Life; 2021; 14(3):383-389. PubMed ID: 34377205
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Closed hollow bulb obturator--one-step fabrication: a clinical report.
    Buzayan MM; Ariffin YT; Yunus N
    J Prosthodont; 2013 Oct; 22(7):591-595. PubMed ID: 23551843
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Two-piece hollow bulb obturator.
    Elangovan S; Loibi E
    Indian J Dent Res; 2011; 22(3):486-8. PubMed ID: 22048595
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A simple method of enhancing retention in interim hollow bulb obturator in a case of an acquired palatal defect.
    Karthikeyan S; Balu K; Devaki V; Ajay R
    J Pharm Bioallied Sci; 2015 Aug; 7(Suppl 2):S782-5. PubMed ID: 26538969
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.