BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 38008417)

  • 1. The first clinical implementation of real-time 6 degree-of-freedom image-guided radiotherapy for liver SABR patients.
    Sengupta C; Nguyen DT; Moodie T; Mason D; Luo J; Causer T; Liu SF; Brown E; Inskip L; Hazem M; Chao M; Wang T; Lee YY; van Gysen K; Sullivan E; Cosgriff E; Ramachandran P; Poulsen P; Booth J; O'Brien R; Greer P; Keall P
    Radiother Oncol; 2024 Jan; 190():110031. PubMed ID: 38008417
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Study protocol of the LARK (TROG 17.03) clinical trial: a phase II trial investigating the dosimetric impact of Liver Ablative Radiotherapy using Kilovoltage intrafraction monitoring.
    Lee YYD; Nguyen DT; Moodie T; O'Brien R; McMaster A; Hickey A; Pritchard N; Poulsen P; Tabaksblat EM; Weber B; Worm E; Pryor D; Chu J; Hardcastle N; Booth J; Gebski V; Wang T; Keall P
    BMC Cancer; 2021 May; 21(1):494. PubMed ID: 33941111
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The first clinical implementation of a real-time six degree of freedom target tracking system during radiation therapy based on Kilovoltage Intrafraction Monitoring (KIM).
    Nguyen DT; O'Brien R; Kim JH; Huang CY; Wilton L; Greer P; Legge K; Booth JT; Poulsen PR; Martin J; Keall PJ
    Radiother Oncol; 2017 Apr; 123(1):37-42. PubMed ID: 28342648
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The accuracy and precision of Kilovoltage Intrafraction Monitoring (KIM) six degree-of-freedom prostate motion measurements during patient treatments.
    Kim JH; Nguyen DT; Booth JT; Huang CY; Fuangrod T; Poulsen P; O'Brien R; Caillet V; Eade T; Kneebone A; Keall P
    Radiother Oncol; 2018 Feb; 126(2):236-243. PubMed ID: 29471970
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The accuracy and precision of the KIM motion monitoring system used in the multi-institutional TROG 15.01 Stereotactic Prostate Ablative Radiotherapy with KIM (SPARK) trial.
    Hewson EA; Nguyen DT; O'Brien R; Kim JH; Montanaro T; Moodie T; Greer PB; Hardcastle N; Eade T; Kneebone A; Hruby G; Hayden AJ; Turner S; Siva S; Tai KH; Hunter P; Sams J; Poulsen PR; Booth JT; Martin J; Keall PJ
    Med Phys; 2019 Nov; 46(11):4725-4737. PubMed ID: 31446633
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An interdimensional correlation framework for real-time estimation of six degree of freedom target motion using a single x-ray imager during radiotherapy.
    Nguyen DT; Bertholet J; Kim JH; O'Brien R; Booth JT; Poulsen PR; Keall PJ
    Phys Med Biol; 2017 Dec; 63(1):015010. PubMed ID: 29106377
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Real-Time 3D Image Guidance Using a Standard LINAC: Measured Motion, Accuracy, and Precision of the First Prospective Clinical Trial of Kilovoltage Intrafraction Monitoring-Guided Gating for Prostate Cancer Radiation Therapy.
    Keall PJ; Ng JA; Juneja P; O'Brien RT; Huang CY; Colvill E; Caillet V; Simpson E; Poulsen PR; Kneebone A; Eade T; Booth JT
    Int J Radiat Oncol Biol Phys; 2016 Apr; 94(5):1015-21. PubMed ID: 27026307
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The first clinical implementation of real-time image-guided adaptive radiotherapy using a standard linear accelerator.
    Keall PJ; Nguyen DT; O'Brien R; Caillet V; Hewson E; Poulsen PR; Bromley R; Bell L; Eade T; Kneebone A; Martin J; Booth JT
    Radiother Oncol; 2018 Apr; 127(1):6-11. PubMed ID: 29428258
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An augmented correlation framework for the estimation of tumour translational and rotational motion during external beam radiotherapy treatments using intermittent monoscopic x-ray imaging and an external respiratory signal.
    Nguyen DT; Booth JT; Caillet V; Hardcastle N; Briggs A; Haddad C; Eade T; O'Brien R; Keall PJ
    Phys Med Biol; 2018 Oct; 63(20):205003. PubMed ID: 30183677
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical implementation of intrafraction cone beam computed tomography imaging during lung tumor stereotactic ablative radiation therapy.
    Li R; Han B; Meng B; Maxim PG; Xing L; Koong AC; Diehn M; Loo BW
    Int J Radiat Oncol Biol Phys; 2013 Dec; 87(5):917-23. PubMed ID: 24113060
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The first clinical treatment with kilovoltage intrafraction monitoring (KIM): a real-time image guidance method.
    Keall PJ; Aun Ng J; O'Brien R; Colvill E; Huang CY; Rugaard Poulsen P; Fledelius W; Juneja P; Simpson E; Bell L; Alfieri F; Eade T; Kneebone A; Booth JT
    Med Phys; 2015 Jan; 42(1):354-8. PubMed ID: 25563275
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Real-Time Image Guided Ablative Prostate Cancer Radiation Therapy: Results From the TROG 15.01 SPARK Trial.
    Keall P; Nguyen DT; O'Brien R; Hewson E; Ball H; Poulsen P; Booth J; Greer P; Hunter P; Wilton L; Bromley R; Kipritidis J; Eade T; Kneebone A; Hruby G; Moodie T; Hayden A; Turner S; Arumugam S; Sidhom M; Hardcastle N; Siva S; Tai KH; Gebski V; Martin J
    Int J Radiat Oncol Biol Phys; 2020 Jul; 107(3):530-538. PubMed ID: 32234553
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Six degrees-of-freedom prostate and lung tumor motion measurements using kilovoltage intrafraction monitoring.
    Huang CY; Tehrani JN; Ng JA; Booth J; Keall P
    Int J Radiat Oncol Biol Phys; 2015 Feb; 91(2):368-75. PubMed ID: 25445555
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the geometric accuracy of surrogate-based gated VMAT using intrafraction kilovoltage x-ray images.
    Li R; Mok E; Han B; Koong A; Xing L
    Med Phys; 2012 May; 39(5):2686-93. PubMed ID: 22559639
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Kilovoltage intrafraction monitoring during normofractionated prostate cancer radiotherapy.
    Chasseray M; Dissaux G; Lucia F; Boussion N; Goasduff G; Pradier O; Bourbonne V; Schick U
    Cancer Radiother; 2020 Apr; 24(2):99-105. PubMed ID: 32201058
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Automatic online and real-time tumour motion monitoring during stereotactic liver treatments on a conventional linac by combined optical and sparse monoscopic imaging with kilovoltage x-rays (COSMIK).
    Bertholet J; Toftegaard J; Hansen R; Worm ES; Wan H; Parikh PJ; Weber B; Høyer M; Poulsen PR
    Phys Med Biol; 2018 Mar; 63(5):055012. PubMed ID: 29516868
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Triggered kV Imaging During Spine SBRT for Intrafraction Motion Management.
    Koo J; Nardella L; Degnan M; Andreozzi J; Yu HM; Penagaricano J; Johnstone PAS; Oliver D; Ahmed K; Rosenberg SA; Wuthrick E; Diaz R; Feygelman V; Latifi K; Moros EG; Redler G
    Technol Cancer Res Treat; 2021; 20():15330338211063033. PubMed ID: 34855577
    [No Abstract]   [Full Text] [Related]  

  • 18. Is multileaf collimator tracking or gating a better intrafraction motion adaptation strategy? An analysis of the TROG 15.01 stereotactic prostate ablative radiotherapy with KIM (SPARK) trial.
    Hewson EA; Nguyen DT; O'Brien R; Poulsen PR; Booth JT; Greer P; Eade T; Kneebone A; Hruby G; Moodie T; Hayden AJ; Turner SL; Hardcastle N; Siva S; Tai KH; Martin J; Keall PJ
    Radiother Oncol; 2020 Oct; 151():234-241. PubMed ID: 32828839
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quality assurance for the clinical implementation of kilovoltage intrafraction monitoring for prostate cancer VMAT.
    Ng JA; Booth JT; O'Brien RT; Colvill E; Huang CY; Poulsen PR; Keall PJ
    Med Phys; 2014 Nov; 41(11):111712. PubMed ID: 25370626
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of dosimetric impact of intrafraction translation and rotation during respiratory-gated stereotactic body radiotherapy with real-time tumor monitoring of the lung using a novel six degrees-of-freedom robotic moving phantom.
    Shiinoki T; Fujii F; Yuasa Y; Nonomura T; Fujimoto K; Sera T; Tanaka H
    Med Phys; 2020 Sep; 47(9):3870-3881. PubMed ID: 32623741
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.