These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

52 related articles for article (PubMed ID: 3801946)

  • 1. [Reference areas in the localization of end points of instantaneous QRS vectors in the Frank lead system using computerized evaluation].
    Bachárová L; Melotová J
    Bratisl Lek Listy; 1986 Dec; 86(6):603-11. PubMed ID: 3801946
    [No Abstract]   [Full Text] [Related]  

  • 2. [Reference values of QRS-complex amplitude parameters in computer evaluation of Frank's orthogonal electrocardiogram].
    Bachárová L; Melotová J
    Bratisl Lek Listy; 1992 May; 93(5):230-8. PubMed ID: 1393644
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of respiration on the vectorcardiogram obtained with the Frank lead system.
    Yamada N
    Acta Med Okayama; 1985 Aug; 39(4):297-313. PubMed ID: 4050536
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Reference values of dipolar electrocardiotopography of the QRS complex].
    Bachárová L; Melotová J; Ruttkay-Nedecký I
    Bratisl Lek Listy; 1991 Aug; 92(8):402-9. PubMed ID: 1913206
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Visual transform applications for estimating the spatial QRS-T angle from the conventional 12-lead ECG: Kors is still most Frank.
    Cortez D; Sharma N; Devers C; Devers E; Schlegel TT
    J Electrocardiol; 2014; 47(1):12-9. PubMed ID: 24099887
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Normal areas of end points of vectorcardiographic vectors QRS and T (author's transl)].
    Ruttkay-Nedecký I; Ruttkay-Nedecký P
    Bratisl Lek Listy; 1982 Apr; 77(4):403-12. PubMed ID: 7093749
    [No Abstract]   [Full Text] [Related]  

  • 7. A comparison between Frank and SVEC III lead systems in normal subjects.
    Tuna N; Finkelstein S; Biessener W; Jelatis G; Tiller M
    J Electrocardiol; 1980; 13(3):219-26. PubMed ID: 7410993
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Quantative analysis of VCG by the Frank lead system; comments on half-area vectors and the accuracy of criteria of maximum QRS and T vectors].
    Mori N; Shibata T; Oshita K; Takeshita I; Hidaka Y
    Nihon Rinsho; 1965 Dec; 23(12):2464-6. PubMed ID: 5895356
    [No Abstract]   [Full Text] [Related]  

  • 9. Vectorcardiographic QRS area as a novel predictor of response to cardiac resynchronization therapy.
    van Deursen CJ; Vernooy K; Dudink E; Bergfeldt L; Crijns HJ; Prinzen FW; Wecke L
    J Electrocardiol; 2015; 48(1):45-52. PubMed ID: 25453196
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Effect of deep inspiration on momentary QRS vectors in healthy subjects on application of the McFee-Parungao system of leads (author's transl)].
    Ruttkay-Nedecký I
    Bratisl Lek Listy; 1976 Jun; 65(6):607-13. PubMed ID: 974824
    [No Abstract]   [Full Text] [Related]  

  • 11. Comparative dipolar electrocardiotopographic study of ventricular activation in Macaca mulatta monkeys and man.
    Ruttkay-Nedecký I
    Physiol Res; 2004; 53(2):143-7. PubMed ID: 15046549
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Normal values by age specificity in Frank lead vectorcardiography--QRS].
    Ueda H; Murao S; Harumi K; Majima S; Matsuo H
    Nihon Rinsho; 1969 Jul; 27(7):1950-3. PubMed ID: 5391084
    [No Abstract]   [Full Text] [Related]  

  • 13. [Posterobasal infarction and right bundle branch block: value of computerized vectorcardiography].
    Timpone G; Nicolai P; Lefevre J; Guerrini P; Delaage M
    Arch Mal Coeur Vaiss; 1982 Jul; 75(7):775-84. PubMed ID: 6810806
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Normal limits of pediatric Frank lead electrocardiograms. Differences in data obtained in 4th or 5th intercostal spaces.
    Robert A; Derwael-Barchy C; Fesler R; Brasseur LA; Brohet CR
    Jpn Heart J; 1984 Jan; 25(1):1-18. PubMed ID: 6737695
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Octant vectorcardiography - the evaluation by peaks.
    Laufberger V
    Physiol Bohemoslov; 1982; 31(1):1-9. PubMed ID: 6461867
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Studies on the reliability of the polarcardiographic records (author's transl)].
    Hashimoto E; Nakaya Y; Ueda S; Aihara T; Nagao T
    Jpn Circ J; 1977 Jan; 41(1):33-4, 59-66. PubMed ID: 839633
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The spatial QRS-T angle in the Frank vectorcardiogram: accuracy of estimates derived from the 12-lead electrocardiogram.
    Schreurs CA; Algra AM; Man SC; Cannegieter SC; van der Wall EE; Schalij MJ; Kors JA; Swenne CA
    J Electrocardiol; 2010; 43(4):294-301. PubMed ID: 20417936
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [A QRS scoring system using the Frank lead vectorcardiogram and its clinical evaluation].
    Tsuya T
    Kokyu To Junkan; 1986 Sep; 34(9):991-7. PubMed ID: 3786966
    [No Abstract]   [Full Text] [Related]  

  • 19. The synthesized vectorcardiogram resembles the measured vectorcardiogram in patients with dyssynchronous heart failure.
    Engels EB; Alshehri S; van Deursen CJ; Wecke L; Bergfeldt L; Vernooy K; Prinzen FW
    J Electrocardiol; 2015; 48(4):586-92. PubMed ID: 25900820
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Correlations with vectorcardiogram variables].
    Scheidt E
    Methods Inf Med Suppl; 1976; 9():199-204. PubMed ID: 1078428
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 3.