117 related articles for article (PubMed ID: 38021215)
1. A large 'Active Magnetic Shield' for a high-precision experiment: nEDM collaboration.
Abel C; Ayres NJ; Ban G; Bison G; Bodek K; Bondar V; Bouillaud T; Chanel E; Chen J; Chen W; Chiu PJ; Crawford CB; Daum M; Doorenbos CB; Emmenegger S; Ferraris-Bouchez L; Fertl M; Fratangelo A; Griffith WC; Grujic ZD; Harris P; Kirch K; Kletzl V; Koss PA; Krempel J; Lauss B; Lefort T; Mullan P; Naviliat-Cuncic O; Pais D; Piegsa FM; Pignol G; Rawlik M; Rienäcker I; Ries D; Roccia S; Rozpedzik D; Saenz-Arevalo W; Schmidt-Wellenburg P; Schnabel A; Segarra EP; Severijns N; Shelton T; Svirina K; Tavakoli Dinani R; Thorne J; Virot R; Yazdandoost N; Zejma J; Ziehl N; Zsigmond G
Eur Phys J C Part Fields; 2023; 83(11):1061. PubMed ID: 38021215
[TBL] [Abstract][Full Text] [Related]
2. Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments.
Ayres NJ; Ban G; Bison G; Bodek K; Bondar V; Bouillaud T; Bowles D; Chanel E; Chen W; Chiu PJ; Crawford CB; Naviliat-Cuncic O; Doorenbos CB; Emmenegger S; Fertl M; Fratangelo A; Griffith WC; Grujic ZD; Harris PG; Kirch K; Kletzl V; Krempel J; Lauss B; Lefort T; Lejuez A; Li R; Mullan P; Pacura S; Pais D; Piegsa FM; Rienäcker I; Ries D; Pignol G; Rebreyend D; Roccia S; Rozpedzik D; Saenz-Arevalo W; Schmidt-Wellenburg P; Schnabel A; Segarra EP; Severijns N; Svirina K; Tavakoli Dinani R; Thorne J; Vankeirsbilck J; Voigt J; Yazdandoost N; Zejma J; Ziehl N; Zsigmond G; nEDM Collaboration At Psi T
Eur Phys J C Part Fields; 2024; 84(1):18. PubMed ID: 38205101
[TBL] [Abstract][Full Text] [Related]
3. The very large n2EDM magnetically shielded room with an exceptional performance for fundamental physics measurements.
Ayres NJ; Ban G; Bison G; Bodek K; Bondar V; Bouillaud T; Clement B; Chanel E; Chiu PJ; Crawford CB; Daum M; Doorenbos CB; Emmenegger S; Fratangelo A; Fertl M; Griffith WC; Grujic ZD; Harris PG; Kirch K; Krempel J; Lauss B; Lefort T; Naviliat-Cuncic O; Pais D; Piegsa FM; Pignol G; Rauscher G; Rebreyend D; Rienäcker I; Ries D; Roccia S; Rozpedzik D; Saenz-Arevalo W; Schmidt-Wellenburg P; Schnabel A; Severijns N; Shen B; Staab M; Svirina K; Dinani RT; Thorne J; Yazdandoost N; Zejma J; Zsigmond G;
Rev Sci Instrum; 2022 Sep; 93(9):095105. PubMed ID: 36182526
[TBL] [Abstract][Full Text] [Related]
4. The design of the n2EDM experiment: nEDM Collaboration.
Ayres NJ; Ban G; Bienstman L; Bison G; Bodek K; Bondar V; Bouillaud T; Chanel E; Chen J; Chiu PJ; Clément B; Crawford CB; Daum M; Dechenaux B; Doorenbos CB; Emmenegger S; Ferraris-Bouchez L; Fertl M; Fratangelo A; Flaux P; Goupillière D; Griffith WC; Grujic ZD; Harris PG; Kirch K; Koss PA; Krempel J; Lauss B; Lefort T; Lemière Y; Leredde A; Meier M; Menu J; Mullins DA; Naviliat-Cuncic O; Pais D; Piegsa FM; Pignol G; Quéméner G; Rawlik M; Rebreyend D; Rienäcker I; Ries D; Roccia S; Ross KU; Rozpedzik D; Saenz W; Schmidt-Wellenburg P; Schnabel A; Severijns N; Shen B; Stapf T; Svirina K; Tavakoli Dinani R; Touati S; Thorne J; Virot R; Voigt J; Wursten E; Yazdandoost N; Zejma J; Zsigmond G
Eur Phys J C Part Fields; 2021; 81(6):512. PubMed ID: 34720721
[TBL] [Abstract][Full Text] [Related]
5. A lightweight magnetically shielded room with active shielding.
Holmes N; Rea M; Chalmers J; Leggett J; Edwards LJ; Nell P; Pink S; Patel P; Wood J; Murby N; Woolger D; Dawson E; Mariani C; Tierney TM; Mellor S; O'Neill GC; Boto E; Hill RM; Shah V; Osborne J; Pardington R; Fierlinger P; Barnes GR; Glover P; Brookes MJ; Bowtell R
Sci Rep; 2022 Aug; 12(1):13561. PubMed ID: 35945239
[TBL] [Abstract][Full Text] [Related]
6. Data blinding for the nEDM experiment at PSI.
Ayres NJ; Ban G; Bison G; Bodek K; Bondar V; Chanel E; Chiu PJ; Crawford CB; Daum M; Emmenegger S; Ferraris-Bouchez L; Flaux P; Grujić Z; Harris PG; Hild N; Hommet J; Kasprzak M; Kermaïdic Y; Kirch K; Komposch S; Kozela A; Krempel J; Lauss B; Lefort T; Lemiere Y; Leredde A; Mohanmurthy P; Mtchedlishvili A; Naviliat-Cuncic O; Pais D; Piegsa FM; Pignol G; Rawlik M; Rebreyend D; Rienäcker I; Ries D; Roccia S; Rozpedzik D; Schmidt-Wellenburg P; Schnabel A; Virot R; Weis A; Wursten E; Zejma J; Zsigmond G
Eur Phys J A Hadron Nucl; 2021; 57(4):152. PubMed ID: 34776778
[TBL] [Abstract][Full Text] [Related]
7. A high-performance compact magnetic shield for optically pumped magnetometer-based magnetoencephalography.
He K; Wan S; Sheng J; Liu D; Wang C; Li D; Qin L; Luo S; Qin J; Gao JH
Rev Sci Instrum; 2019 Jun; 90(6):064102. PubMed ID: 31254989
[TBL] [Abstract][Full Text] [Related]
8. Bespoke magnetic field design for a magnetically shielded cold atom interferometer.
Hobson PJ; Vovrosh J; Stray B; Packer M; Winch J; Holmes N; Hayati F; McGovern K; Bowtell R; Brookes MJ; Bongs K; Fromhold TM; Holynski M
Sci Rep; 2022 Jun; 12(1):10520. PubMed ID: 35732872
[TBL] [Abstract][Full Text] [Related]
9. Magnetic Field Stabilization for Magnetically Shielded Volumes by External Field Coils.
Brys T; Czekaj S; Daum M; Fierlinger P; George D; Henneck R; Hochman Z; Kasprzak M; Kohlik K; Kirch K; Kuzniak M; Kuehne G; Pichlmaier A; Siodmok A; Szelc A; Tanner L
J Res Natl Inst Stand Technol; 2005; 110(3):173-8. PubMed ID: 27308117
[TBL] [Abstract][Full Text] [Related]
10. Magnetic shielding investigation for a 6 MV in-line linac within the parallel configuration of a linac-MR system.
Santos DM; St Aubin J; Fallone BG; Steciw S
Med Phys; 2012 Feb; 39(2):788-97. PubMed ID: 22320788
[TBL] [Abstract][Full Text] [Related]
11. MCG measurement in the environment of active magnetic shield.
Yamazaki K; Kato K; Kobayashi K; Igarashi A; Sato T; Haga A; Kasai N
Neurol Clin Neurophysiol; 2004 Nov; 2004():40. PubMed ID: 16012640
[TBL] [Abstract][Full Text] [Related]
12. Balanced, bi-planar magnetic field and field gradient coils for field compensation in wearable magnetoencephalography.
Holmes N; Tierney TM; Leggett J; Boto E; Mellor S; Roberts G; Hill RM; Shah V; Barnes GR; Brookes MJ; Bowtell R
Sci Rep; 2019 Oct; 9(1):14196. PubMed ID: 31578383
[TBL] [Abstract][Full Text] [Related]
13. Design and Performance of Laser-Pumped Cs-Magnetometers for the Planned UCN EDM Experiment at PSI.
Groeger S; Bison G; Weis A
J Res Natl Inst Stand Technol; 2005; 110(3):179-83. PubMed ID: 27308118
[TBL] [Abstract][Full Text] [Related]
14. Magnetic field compensation coil design for magnetoencephalography.
Kutschka H; Doeller CF; Haueisen J; Maess B
Sci Rep; 2021 Nov; 11(1):22650. PubMed ID: 34811388
[TBL] [Abstract][Full Text] [Related]
15. Active magnetic compensation composed of shielding panels.
Kato K; Yamazaki K; Sato T; Haga A; Okitsu T; Muramatsu K; Ueda T; Kobayashi K; Yoshizawa M
Neurol Clin Neurophysiol; 2004 Nov; 2004():68. PubMed ID: 16012696
[TBL] [Abstract][Full Text] [Related]
16. A magnetically shielded room with ultra low residual field and gradient.
Altarev I; Babcock E; Beck D; Burghoff M; Chesnevskaya S; Chupp T; Degenkolb S; Fan I; Fierlinger P; Frei A; Gutsmiedl E; Knappe-Grüneberg S; Kuchler F; Lauer T; Link P; Lins T; Marino M; McAndrew J; Niessen B; Paul S; Petzoldt G; Schläpfer U; Schnabel A; Sharma S; Singh J; Stoepler R; Stuiber S; Sturm M; Taubenheim B; Trahms L; Voigt J; Zechlau T
Rev Sci Instrum; 2014 Jul; 85(7):075106. PubMed ID: 25085172
[TBL] [Abstract][Full Text] [Related]
17. Macromolecular crowding: chemistry and physics meet biology (Ascona, Switzerland, 10-14 June 2012).
Foffi G; Pastore A; Piazza F; Temussi PA
Phys Biol; 2013 Aug; 10(4):040301. PubMed ID: 23912807
[TBL] [Abstract][Full Text] [Related]
18. Avoiding eddy-current problems in ultra-low-field MRI with self-shielded polarizing coils.
Nieminen JO; Vesanen PT; Zevenhoven KC; Dabek J; Hassel J; Luomahaara J; Penttilä JS; Ilmoniemi RJ
J Magn Reson; 2011 Sep; 212(1):154-60. PubMed ID: 21784681
[TBL] [Abstract][Full Text] [Related]
19. Electric charging effects on insulating surfaces in cryogenic liquids.
Korsch W; Broering M; Timsina A; Leung KKH; Abney J; Budker D; Filippone BW; He J; Kandu S; McCrea M; Roy M; Swank C; Yao W
Rev Sci Instrum; 2024 Apr; 95(4):. PubMed ID: 38557888
[TBL] [Abstract][Full Text] [Related]
20. Active magnetic shielding for biomagnetic measurement using spatial gradient fields.
Hilgenfeld B; Strähmel E; Nowak H; Haueisen J
Physiol Meas; 2003 Aug; 24(3):661-9. PubMed ID: 14509304
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]