These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 38021398)

  • 1. Additively manufactured Ti-Ta-Cu alloys for the next-generation load-bearing implants.
    Bandyopadhyay A; Mitra I; Ciliveri S; Avila JD; Dernell W; Goodman SB; Bose S
    Int J Extrem Manuf; 2024 Feb; 6(1):015503. PubMed ID: 38021398
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fatigue behavior of additively manufactured Ti3Al2V alloy.
    Bandyopadhyay A; Ciliveri S; Guariento S; Zuckschwerdt N; Hogg WW
    Mater Sci Addit Manuf; 2023 Sep; 2(3):. PubMed ID: 38174053
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Understanding the influence of alloying elements on the print quality of powder bed fusion-based metal additive manufacturing: Ta and Cu addition to Ti alloy.
    Ciliveri S; Bandyopadhyay A
    Virtual Phys Prototyp; 2023; 18(1):. PubMed ID: 38911127
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Additively Manufactured SiO
    Ciliveri S; Bandyopadhyay A
    ACS Appl Mater Interfaces; 2024 Jan; 16(3):3106-3115. PubMed ID: 38214659
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Enhanced osteogenesis and bactericidal performance with additively manufactured MgO and Cu-added CpTi for load-bearing implants.
    Ciliveri S; Bandyopadhyay A
    Int J Bioprint; 2023 Oct; 9(6):. PubMed ID: 38116397
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Functionalization of Biomedical Ti6Al4V via In Situ Alloying by Cu during Laser Powder Bed Fusion Manufacturing.
    Krakhmalev P; Yadroitsev I; Yadroitsava I; de Smidt O
    Materials (Basel); 2017 Oct; 10(10):. PubMed ID: 28972546
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low elastic modulus Ti-Ta alloys for load-bearing permanent implants: enhancing the biodegradation resistance by electrochemical surface engineering.
    Kesteven J; Kannan MB; Walter R; Khakbaz H; Choe HC
    Mater Sci Eng C Mater Biol Appl; 2015 Jan; 46():226-31. PubMed ID: 25491981
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A novel titanium alloy for load-bearing biomedical implants: Evaluating the antibacterial and biocompatibility of Ti536 produced via electron beam powder bed fusion additive manufacturing process.
    Behjat A; Sanaei S; Mosallanejad MH; Atapour M; Sheikholeslam M; Saboori A; Iuliano L
    Biomater Adv; 2024 Oct; 163():213928. PubMed ID: 38941776
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 3D Printing in alloy design to improve biocompatibility in metallic implants.
    Mitra I; Bose S; Dernell WS; Dasgupta N; Eckstrand C; Herrick J; Yaszemski MJ; Goodman SB; Bandyopadhyay A
    Mater Today (Kidlington); 2021 May; 45():20-34. PubMed ID: 34220288
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biodegradable Zn-Cu alloys show antibacterial activity against MRSA bone infection by inhibiting pathogen adhesion and biofilm formation.
    Qu X; Yang H; Jia B; Yu Z; Zheng Y; Dai K
    Acta Biomater; 2020 Nov; 117():400-417. PubMed ID: 33007485
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Molecular mechanisms of osteogenesis and antibacterial activity of Cu-bearing Ti alloy in a bone defect model with infection
    Yang J; Qin H; Chai Y; Zhang P; Chen Y; Yang K; Qin M; Zhang Y; Xia H; Ren L; Yu B
    J Orthop Translat; 2021 Mar; 27():77-89. PubMed ID: 33437640
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preliminary study on the corrosion resistance, antibacterial activity and cytotoxicity of selective-laser-melted Ti6Al4V-xCu alloys.
    Guo S; Lu Y; Wu S; Liu L; He M; Zhao C; Gan Y; Lin J; Luo J; Xu X; Lin J
    Mater Sci Eng C Mater Biol Appl; 2017 Mar; 72():631-640. PubMed ID: 28024632
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the mechanical compatibility of additively manufactured porous Ti-25Ta alloy for load-bearing implant applications.
    Soro N; Attar H; Brodie E; Veidt M; Molotnikov A; Dargusch MS
    J Mech Behav Biomed Mater; 2019 Sep; 97():149-158. PubMed ID: 31121433
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical behavior of in-situ alloyed Ti6Al4V(ELI)-3 at.% Cu lattice structures manufactured by laser powder bed fusion and designed for implant applications.
    Vilardell AM; Takezawa A; du Plessis A; Takata N; Krakhmalev P; Kobashi M; Albu M; Kothleitner G; Yadroitsava I; Yadroitsev I
    J Mech Behav Biomed Mater; 2021 Jan; 113():104130. PubMed ID: 33049622
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of as-cast Ti-Cu alloys.
    Zhang E; Ren J; Li S; Yang L; Qin G
    Biomed Mater; 2016 Oct; 11(6):065001. PubMed ID: 27767022
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Study on mechanical behavior of Cu-bearing antibacterial titanium alloy implant.
    Zhang S; Yu Y; Wang H; Ren L; Yang K
    J Mech Behav Biomed Mater; 2022 Jan; 125():104926. PubMed ID: 34736030
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro and in vivo studies of anti-bacterial copper-bearing titanium alloy for dental application.
    Liu R; Tang Y; Zeng L; Zhao Y; Ma Z; Sun Z; Xiang L; Ren L; Yang K
    Dent Mater; 2018 Aug; 34(8):1112-1126. PubMed ID: 29709241
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microstructure, Wettability, Corrosion Resistance and Antibacterial Property of Cu-MTa
    Ding Z; Wang Y; Zhou Q; Ding Z; Liu J; He Q; Zhang H
    Biomolecules; 2019 Dec; 10(1):. PubMed ID: 31906220
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Additive manufacturing of Zn-Mg alloy porous scaffolds with enhanced osseointegration: In vitro and in vivo studies.
    Qin Y; Liu A; Guo H; Shen Y; Wen P; Lin H; Xia D; Voshage M; Tian Y; Zheng Y
    Acta Biomater; 2022 Jun; 145():403-415. PubMed ID: 35381400
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characteristics of novel Ti-10Mo-xCu alloy by powder metallurgy for potential biomedical implant applications.
    Xu W; Hou C; Mao Y; Yang L; Tamaddon M; Zhang J; Qu X; Liu C; Su B; Lu X
    Bioact Mater; 2020 Sep; 5(3):659-666. PubMed ID: 32420516
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.