These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 38025856)

  • 1. Highly sensitive detection of circulating tumour cells based on an ASV/CV dual-signal electrochemical strategy.
    Wang G; Han D; Zhang Q
    RSC Adv; 2023 Nov; 13(47):33038-33046. PubMed ID: 38025856
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Aptamer-DNA concatamer-quantum dots based electrochemical biosensing strategy for green and ultrasensitive detection of tumor cells via mercury-free anodic stripping voltammetry.
    Zheng Y; Wang X; He S; Gao Z; Di Y; Lu K; Li K; Wang J
    Biosens Bioelectron; 2019 Feb; 126():261-268. PubMed ID: 30445301
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dual-aptamer based electrochemical sandwich biosensor for MCF-7 human breast cancer cells using silver nanoparticle labels and a poly(glutamic acid)/MWNT nanocomposite.
    Yazdanparast S; Benvidi A; Banaei M; Nikukar H; Tezerjani MD; Azimzadeh M
    Mikrochim Acta; 2018 Aug; 185(9):405. PubMed ID: 30094655
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Faraday cage-type immunosensor for dual-modal detection of Vibrio parahaemolyticus by electrochemiluminescence and anodic stripping voltammetry.
    Wang T; Song X; Lin H; Hao T; Hu Y; Wang S; Su X; Guo Z
    Anal Chim Acta; 2019 Jul; 1062():124-130. PubMed ID: 30947988
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic bead-based electrochemical and colorimetric assays of circulating tumor cells with boronic acid derivatives as the recognition elements and signal probes.
    Xia N; Wu D; Yu H; Sun W; Yi X; Liu L
    Talanta; 2021 Jan; 221():121640. PubMed ID: 33076160
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids.
    Alghamdi AF
    J Food Drug Anal; 2014 Sep; 22(3):363-369. PubMed ID: 28911427
    [TBL] [Abstract][Full Text] [Related]  

  • 7. CdSe@CdS quantum dot-sensitized Au/α-Fe
    Wang J; Gao Z; Dong M; Li J; Jiang H; Xu J; Gu J; Wang D
    Mikrochim Acta; 2023 May; 190(6):221. PubMed ID: 37183218
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reversible capturing and voltammetric determination of circulating tumor cells using two-dimensional nanozyme based on PdMo decorated with gold nanoparticles and aptamer.
    Yang W; Fan L; Guo Z; Wu H; Chen J; Liu C; Yan Y; Ding S
    Mikrochim Acta; 2021 Sep; 188(10):319. PubMed ID: 34476628
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Functioning of antimony film electrode in acid media under cyclic and anodic stripping voltammetry conditions.
    Sebez B; Ogorevc B; Hocevar SB; Veber M
    Anal Chim Acta; 2013 Jun; 785():43-9. PubMed ID: 23764442
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intelligent recognition of CTCs from gallbladder cancer by ultrasensitive electrochemical cytosensor and diagnosis of chemotherapeutic resistance.
    Zhang X; Li L; Zhang M; Zhang L; Liu S; Guo J; Jiang N; Peng Q; Wang J; Ding S
    Biosens Bioelectron; 2023 May; 228():115183. PubMed ID: 36905863
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Highly Sensitive Electrochemical Biosensor for Circulating Tumor Cells Detection via Dual-Aptamer Capture and Rolling Circle Amplification Strategy.
    Wang Y; Chang K; Yang C; Li S; Wang L; Xu H; Zhou L; Zhang W; Tang X; Wang Y; Chen M
    J Biomed Nanotechnol; 2019 Jul; 15(7):1568-1577. PubMed ID: 31196359
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Aptamer based strategy for cytosensing and evaluation of HER-3 on the surface of MCF-7 cells by using the signal amplification of nucleic acid-functionalized nanocrystals.
    Lv S; Guan Y; Wang D; Du Y
    Anal Chim Acta; 2013 Apr; 772():26-32. PubMed ID: 23540244
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Engineering Biomimetic Biosensor Using Dual-Targeting Multivalent Aptamer Regulated 3D DNA Walker Enables High-Performance Detection of Heterogeneous Circulating Tumor Cells.
    Jia L; Hu Q; Zhang T; Wang Z; Wu D; Xie X; Wang S
    Small; 2023 Sep; 19(38):e2302542. PubMed ID: 37222122
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nondestructive separation/enrichment and rolling circle amplification-powered sensitive SERS enumeration of circulating tumor cells via aptamer recognition.
    Li J; Dong C; Gan H; Gu X; Zhang J; Zhu Y; Xiong J; Song C; Wang L
    Biosens Bioelectron; 2023 Jul; 231():115273. PubMed ID: 37054599
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A dual-recognition-controlled electrochemical biosensor for accurate and sensitive detection of specific circulating tumor cells.
    Peng Y; Lu B; Deng Y; Yang N; Li G
    Biosens Bioelectron; 2022 Apr; 201():113973. PubMed ID: 35021133
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Enhancing selectivity in stripping voltammetry by different adsorption behaviors: the use of nanostructured Mg-Al-layered double hydroxides to detect Cd(II).
    Xu RX; Yu XY; Gao C; Liu JH; Compton RG; Huang XJ
    Analyst; 2013 Mar; 138(6):1812-8. PubMed ID: 23370265
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel electrochemical biosensor based on polyadenine modified aptamer for label-free and ultrasensitive detection of human breast cancer cells.
    Wang K; He MQ; Zhai FH; He RH; Yu YL
    Talanta; 2017 May; 166():87-92. PubMed ID: 28213264
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrochemical Detection of Circulating Tumor Cells Based on DNA Generated Electrochemical Current and Rolling Circle Amplification.
    Shen C; Liu S; Li X; Yang M
    Anal Chem; 2019 Sep; 91(18):11614-11619. PubMed ID: 31452368
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electrochemical assay for analysis of circulation tumor cells based on isolation of the cell with magnetic nanoparticles and reaction of DNA with molybdate.
    Hou Y; Chen J; Xie B; Li T; Yang M
    Mikrochim Acta; 2020 Jul; 187(7):420. PubMed ID: 32617688
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An electrochemical biosensor based on hemin/G-quadruplex DNAzyme and PdRu/Pt heterostructures as signal amplifier for circulating tumor cells detection.
    Zhou X; Pu Q; Yu H; Peng Y; Li J; Yang Y; Chen H; Weng Y; Xie G
    J Colloid Interface Sci; 2021 Oct; 599():752-761. PubMed ID: 33989928
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.