These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 38032250)
21. Single test rule-out of acute myocardial infarction using the limit of detection of a new high-sensitivity troponin I assay. Body R; Morris N; Collinson P Clin Biochem; 2020 Apr; 78():4-9. PubMed ID: 32135083 [TBL] [Abstract][Full Text] [Related]
22. Reference population and marathon runner sera assessed by highly sensitive cardiac troponin T and commercial cardiac troponin T and I assays. Mingels A; Jacobs L; Michielsen E; Swaanenburg J; Wodzig W; van Dieijen-Visser M Clin Chem; 2009 Jan; 55(1):101-8. PubMed ID: 18988757 [TBL] [Abstract][Full Text] [Related]
23. Determination of high-sensitivity cardiac troponin I 99th percentile upper reference limits in a healthy Korean population. Ji M; Moon HW; Hur M; Yun YM Clin Biochem; 2016 Jul; 49(10-11):756-61. PubMed ID: 27067595 [TBL] [Abstract][Full Text] [Related]
25. No increase in the incidence of cardiac troponin I concentration above the 99th percentile by Siemens Centaur high-sensitivity compared to the contemporary assay. Yang HS; Shemesh A; Li J; Xie T; Apple FS; Williams J; Zhao Z; Steel PAD Clin Biochem; 2021 Mar; 89():77-80. PubMed ID: 33296707 [TBL] [Abstract][Full Text] [Related]
26. Improved sensitivity of point of care troponin I values using reporting to below the 99 th percentile of normals. Schneider HG; Ablitt P; Taylor J Clin Biochem; 2013 Aug; 46(12):979-982. PubMed ID: 23628595 [TBL] [Abstract][Full Text] [Related]
27. Analytical characterization and clinical performance evaluation of a new point-of-care testing system for high-sensitivity cardiac troponin I assay. Zhang R; Hong Y; Shi J; Zhao R; Song Y; Li Z; Wang Q Ann Clin Biochem; 2021 Nov; 58(6):579-585. PubMed ID: 34120481 [TBL] [Abstract][Full Text] [Related]
28. Analytical Concordance of Diverse Point-of-Care and Central Laboratory Troponin I Assays. Tsui AKY; Lyon ME; van Diepen S; Goudreau BL; Thomas D; Higgins T; Raizman JE; Füzéry AK; Rodriguez-Capote K; Estey M; Cembrowski G J Appl Lab Med; 2019 Mar; 3(5):764-774. PubMed ID: 31639752 [TBL] [Abstract][Full Text] [Related]
29. Diagnostic accuracy of the Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision aid with a point-of-care cardiac troponin assay. Alghamdi A; Reynard C; Morris N; Moss P; Jarman H; Hardy E; Harris T; Horner D; Parris R; Body R Emerg Med J; 2020 Apr; 37(4):223-228. PubMed ID: 32047076 [TBL] [Abstract][Full Text] [Related]
31. Validity of a Novel Point-of-Care Troponin Assay for Single-Test Rule-Out of Acute Myocardial Infarction. Pickering JW; Young JM; George PM; Watson AS; Aldous SJ; Troughton RW; Pemberton CJ; Richards AM; Cullen LA; Than MP JAMA Cardiol; 2018 Nov; 3(11):1108-1112. PubMed ID: 30347004 [TBL] [Abstract][Full Text] [Related]
32. Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I. Boeddinghaus J; Nestelberger T; Koechlin L; Wussler D; Lopez-Ayala P; Walter JE; Troester V; Ratmann PD; Seidel F; Zimmermann T; Badertscher P; Wildi K; Rubini Giménez M; Potlukova E; Strebel I; Freese M; Miró Ò; Martin-Sanchez FJ; Kawecki D; Keller DI; Gualandro DM; Christ M; Twerenbold R; Mueller C; J Am Coll Cardiol; 2020 Mar; 75(10):1111-1124. PubMed ID: 32164884 [TBL] [Abstract][Full Text] [Related]
33. Performance of the AQT90 FLEX cTnI point-of-care assay for the rapid diagnosis of acute myocardial infarction in the emergency room. Ivandic BT; Spanuth E; Giannitsis E Clin Lab; 2014; 60(6):903-8. PubMed ID: 25016693 [TBL] [Abstract][Full Text] [Related]
34. Diagnostic performance of four point of care cardiac troponin I assays to rule in and rule out acute myocardial infarction. Palamalai V; Murakami MM; Apple FS Clin Biochem; 2013 Nov; 46(16-17):1631-5. PubMed ID: 23850852 [TBL] [Abstract][Full Text] [Related]
35. The clinical and diagnostic performance characteristics of the high sensitivity Abbott cardiac troponin I assay. Collinson PO; Gaze D; Goodacre S Clin Biochem; 2015 Mar; 48(4-5):275-81. PubMed ID: 25549978 [TBL] [Abstract][Full Text] [Related]
36. Combining presentation high-sensitivity cardiac troponin I and glucose measurements to rule-out an acute myocardial infarction in patients presenting to emergency department with chest pain. Greenslade JH; Kavsak P; Parsonage W; Shortt C; Than M; Pickering JW; Aldous S; Cullen L Clin Biochem; 2015 Mar; 48(4-5):288-91. PubMed ID: 25485933 [TBL] [Abstract][Full Text] [Related]
37. High-sensitivity cardiac troponin assays: From improved analytical performance to enhanced risk stratification. Kozinski M; Krintus M; Kubica J; Sypniewska G Crit Rev Clin Lab Sci; 2017 May; 54(3):143-172. PubMed ID: 28457177 [TBL] [Abstract][Full Text] [Related]
38. Trial design for assessing analytical and clinical performance of high-sensitivity cardiac troponin I assays in the United States: The HIGH-US study. Christenson RH; Peacock WF; Apple FS; Limkakeng AT; Nowak RM; McCord J; deFilippi CR Contemp Clin Trials Commun; 2019 Jun; 14():100337. PubMed ID: 30834354 [TBL] [Abstract][Full Text] [Related]
39. Rapid exclusion of acute myocardial infarction in patients with undetectable troponin using a sensitive troponin I assay. Body R; Burrows G; Carley S; Lewis PS Ann Clin Biochem; 2015 Sep; 52(Pt 5):543-9. PubMed ID: 25713467 [TBL] [Abstract][Full Text] [Related]
40. Frequency histograms of three high-sensitivity cardiac troponin assays in a reference population. Cho H; Kim H; Lee J; Kim SY; Lee HK; Kwon HJ; Kim Y J Clin Lab Anal; 2022 Jun; 36(6):e24432. PubMed ID: 35441734 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]