These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 38035376)

  • 1. Automatic stent struts detection in optical coherence tomography based on a multiple attention convolutional model.
    Han T; Xia W; Tao K; Wang W; Gao J; Ding X; Zhong H; Liu R; Dou S; Liu Z; Kuang H; Hua J; Xu K
    Phys Med Biol; 2023 Dec; 69(1):. PubMed ID: 38035376
    [No Abstract]   [Full Text] [Related]  

  • 2. Automated segmentation of metal stent and bioresorbable vascular scaffold in intravascular optical coherence tomography images using deep learning architectures.
    Lau YS; Tan LK; Chan CK; Chee KH; Liew YM
    Phys Med Biol; 2021 Dec; 66(24):. PubMed ID: 34911053
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method.
    Chiastra C; Montin E; Bologna M; Migliori S; Aurigemma C; Burzotta F; Celi S; Dubini G; Migliavacca F; Mainardi L
    PLoS One; 2017; 12(6):e0177495. PubMed ID: 28574987
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated detection of vessel lumen and stent struts in intravascular optical coherence tomography to evaluate stent apposition and neointimal coverage.
    Nam HS; Kim CS; Lee JJ; Song JW; Kim JW; Yoo H
    Med Phys; 2016 Apr; 43(4):1662. PubMed ID: 27036565
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.
    Izumi D; Miyahara M; Fujimoto N; Fukuoka S; Sakai M; Dohi K; Ito M
    Heart Vessels; 2016 Aug; 31(8):1247-56. PubMed ID: 26334709
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automatic segmentation of optical coherence tomography pullbacks of coronary arteries treated with bioresorbable vascular scaffolds: Application to hemodynamics modeling.
    Bologna M; Migliori S; Montin E; Rampat R; Dubini G; Migliavacca F; Mainardi L; Chiastra C
    PLoS One; 2019; 14(3):e0213603. PubMed ID: 30870477
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optical Coherence Tomography Findings in Patients With Coronary Stent Thrombosis: A Report of the PRESTIGE Consortium (Prevention of Late Stent Thrombosis by an Interdisciplinary Global European Effort).
    Adriaenssens T; Joner M; Godschalk TC; Malik N; Alfonso F; Xhepa E; De Cock D; Komukai K; Tada T; Cuesta J; Sirbu V; Feldman LJ; Neumann FJ; Goodall AH; Heestermans T; Buysschaert I; Hlinomaz O; Belmans A; Desmet W; Ten Berg JM; Gershlick AH; Massberg S; Kastrati A; Guagliumi G; Byrne RA;
    Circulation; 2017 Sep; 136(11):1007-1021. PubMed ID: 28720725
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optical coherence tomography-guided percutaneous coronary intervention: a review of current clinical applications.
    Kurogi K; Ishii M; Yamamoto N; Yamanaga K; Tsujita K
    Cardiovasc Interv Ther; 2021 Apr; 36(2):169-177. PubMed ID: 33454867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Comparison of Intravascular Imaging Modalities for Detection of Stent Struts in Acute Coronary Syndrome.
    Hyeon SH; Lee WS; Kim DI; Shin ES; Kim KS; Hong YJ; Lee SY; Won H; Kim TH; Kim SW
    J Interv Cardiol; 2016 Feb; 29(1):99-107. PubMed ID: 26864953
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography.
    Chen BX; Ma FY; Luo W; Ruan JH; Xie WL; Zhao XZ; Sun SH; Guo XM; Wang F; Tian T; Chu XW
    Heart; 2008 May; 94(5):566-70. PubMed ID: 17923466
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automatic stent reconstruction in optical coherence tomography based on a deep convolutional model.
    Wu P; Gutiérrez-Chico JL; Tauzin H; Yang W; Li Y; Yu W; Chu M; Guillon B; Bai J; Meneveau N; Wijns W; Tu S
    Biomed Opt Express; 2020 Jun; 11(6):3374-3394. PubMed ID: 32637261
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Automatic stent strut detection in intravascular optical coherence tomographic pullback runs.
    Wang A; Eggermont J; Dekker N; Garcia-Garcia HM; Pawar R; Reiber JH; Dijkstra J
    Int J Cardiovasc Imaging; 2013 Jan; 29(1):29-38. PubMed ID: 22618433
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Healing and early stent coverage after ultrathin strut biodegradable polymer-coated sirolimus-eluting stent implantation: SiBi optical coherence tomography study.
    Abhyankar A; Abizaid A; Chamié D; Patel G
    Catheter Cardiovasc Interv; 2021 Dec; 98(7):1335-1342. PubMed ID: 33247618
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Corner Detection Based Automatic Segmentation of Bioresorbable Vascular Scaffold Struts in IVOCT Images.
    Qin X; Yao L; Jin Q; Jing J; Chen Y; Cao Y; Li J; Zhu R
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():604-607. PubMed ID: 30440469
    [TBL] [Abstract][Full Text] [Related]  

  • 15. First in-human evaluation of a novel intravascular ultrasound and optical coherence tomography system for intracoronary imaging.
    Akl E; Pinilla-Echeverri N; Garcia-Garcia HM; Mehta SR; Dan K; Kuku KO; Courtney BK; Sheth T
    Catheter Cardiovasc Interv; 2022 Feb; 99(3):686-698. PubMed ID: 34792273
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of Stent Expansion Guided by Optical Coherence Tomography Versus Intravascular Ultrasound: The ILUMIEN II Study (Observational Study of Optical Coherence Tomography [OCT] in Patients Undergoing Fractional Flow Reserve [FFR] and Percutaneous Coronary Intervention).
    Maehara A; Ben-Yehuda O; Ali Z; Wijns W; Bezerra HG; Shite J; Généreux P; Nichols M; Jenkins P; Witzenbichler B; Mintz GS; Stone GW
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1704-14. PubMed ID: 26585621
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reciprocal assistance of intravascular imaging in three-dimensional stent reconstruction: Using cross-modal translation based on disentanglement representation.
    Wu P; Qiao Y; Chu M; Zhang S; Bai J; Gutierrez-Chico JL; Tu S
    Comput Med Imaging Graph; 2023 Mar; 104():102166. PubMed ID: 36586195
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Vulnerable struts with CRE8, Biomatrix and Xience stents assessed with OCT and their correlation with clinical variables at 6-month follow-up: the CREBX-OCT study.
    Giglioli C; Formentini C; Romano SM; Cecchi E; Baldereschi GJ; Landi D; Chiostri M; Prati F; Marchionni N
    Int J Cardiovasc Imaging; 2020 Feb; 36(2):217-230. PubMed ID: 31667661
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Histopathological validation of optical coherence tomography findings of the coronary arteries.
    Fujii K; Kawakami R; Hirota S
    J Cardiol; 2018 Sep; 72(3):179-185. PubMed ID: 29655510
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Natural consequence of post-intervention stent malapposition, thrombus, tissue prolapse, and dissection assessed by optical coherence tomography at mid-term follow-up.
    Kawamori H; Shite J; Shinke T; Otake H; Matsumoto D; Nakagawa M; Nagoshi R; Kozuki A; Hariki H; Inoue T; Osue T; Taniguchi Y; Nishio R; Hiranuma N; Hirata K
    Eur Heart J Cardiovasc Imaging; 2013 Sep; 14(9):865-75. PubMed ID: 23291393
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.