BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 38036842)

  • 21. Development of a high performance liquid chromatography method for the simultaneous measurement of prednisone and prednisolone.
    Huber F; Wiedemann M; Heinrich G; Salama Z; Jaeger H
    Arzneimittelforschung; 1990 Aug; 40(8):926-31. PubMed ID: 2242086
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Optimization of solid phase extraction clean up and validation of quantitative determination of corticosteroids in urine by liquid chromatography-tandem mass spectrometry.
    Andersen JH; Hansen LG; Pedersen M
    Anal Chim Acta; 2008 Jun; 617(1-2):216-24. PubMed ID: 18486661
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Development and validation of a liquid chromatography-tandem mass spectrometry assay for the simultaneous quantitation of prednisolone and dipyridamole in human plasma and its application in a pharmacokinetic study.
    Chen M; Granvil C; Ji QC; Zhang ZY; Padval MV; Kansra VV
    J Pharm Biomed Anal; 2009 Jul; 49(5):1241-9. PubMed ID: 19304431
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Determination of 22 phospholipids in serum by ultra performance liquid chromatography-tandem mass spectrometry].
    Wang WR; Peng FD; Li T; Ding CG; Wang HQ
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2023 May; 41(5):366-371. PubMed ID: 37248084
    [No Abstract]   [Full Text] [Related]  

  • 25. Quantification of 6 glucocorticoids in human plasma by liquid chromatography tandem mass spectrometry: method development, validation, and assessment of matrix effects.
    Sæves I; Vethe NT; Bergan S
    Ther Drug Monit; 2011 Aug; 33(4):402-10. PubMed ID: 21743383
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Determination of prednisone and prednisolone in human serum by high-performance liquid chromatography--especially on impaired conversion of corticosteroids in patients with chronic liver disease.
    Ui T; Mitsunaga M; Tanaka T; Horiguchi M
    J Chromatogr; 1982 Apr; 239():711-6. PubMed ID: 7096508
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Ultra fast liquid chromatography-tandem mass spectrometry routine method for simultaneous determination of cyclosporin A, tacrolimus, sirolimus, and everolimus in whole blood using deuterated internal standards for cyclosporin A and everolimus.
    Meinitzer A; Gartner G; Pilz S; Stettin M
    Ther Drug Monit; 2010 Feb; 32(1):61-6. PubMed ID: 20010460
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Determination of the glucocorticoids prednisone, prednisolone, dexamethasone, and cortisol in human serum using liquid chromatography coupled to tandem mass spectrometry.
    Frerichs VA; Tornatore KM
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Apr; 802(2):329-38. PubMed ID: 15018795
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Fifteen years of operation of a high-performance liquid chromatographic assay for prednisolone, cortisol and prednisone in plasma.
    Jusko WJ; Pyszczynski NA; Bushway MS; D'Ambrosio R; Mis SM
    J Chromatogr B Biomed Appl; 1994 Aug; 658(1):47-54. PubMed ID: 7952131
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development and validation of a sensitive liquid chromatography tandem mass spectrometry assay for the simultaneous determination of ten kinase inhibitors in human serum and plasma.
    Aghai F; Zimmermann S; Kurlbaum M; Jung P; Pelzer T; Klinker H; Isberner N; Scherf-Clavel O
    Anal Bioanal Chem; 2021 Jan; 413(2):599-612. PubMed ID: 33155133
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Determination of prednisolone and prednisone in plasma, whole blood, urine, and bound-to-plasma proteins by high-performance liquid chromatography.
    Gai MN; Pinilla E; Paulos C; Chávez J; Puelles V; Arancibia A
    J Chromatogr Sci; 2005 Apr; 43(4):201-6. PubMed ID: 15975236
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Graft Cryopreservation Does Not Impact Overall Survival after Allogeneic Hematopoietic Cell Transplantation Using Post-Transplantation Cyclophosphamide for Graft-versus-Host Disease Prophylaxis.
    Hamadani M; Zhang MJ; Tang XY; Fei M; Brunstein C; Chhabra S; D'Souza A; Milano F; Phelan R; Saber W; Shaw BE; Weisdorf D; Devine SM; Horowitz MM
    Biol Blood Marrow Transplant; 2020 Jul; 26(7):1312-1317. PubMed ID: 32283185
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Determination of ten aminoglycoside residues in eggs by mixed-mode ion exchange liquid chromatography-tandem mass spectrometry].
    Wei L; Xue X; Wu C; Ding Y; Lu L; Wang J; Liu Y
    Se Pu; 2021 Dec; 39(12):1374-1381. PubMed ID: 34812011
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Determination of Treosulfan and Fludarabine in Plasma by Turbulent Flow Liquid Chromatography-Tandem Mass Spectrometry (TFLC-MS/MS).
    Hutcherson SM; Schofield RC; Carlow DC
    Methods Mol Biol; 2024; 2737():453-463. PubMed ID: 38036846
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Development of a liquid chromatography-tandem mass spectrometry method for plasma-free metanephrines with ion-pairing turbulent flow online extraction.
    He X; Kozak M
    Anal Bioanal Chem; 2012 Mar; 402(9):3003-10. PubMed ID: 22349327
    [TBL] [Abstract][Full Text] [Related]  

  • 36. UHPLC assisted simultaneous separation of apigenin and prednisolone and its application in the pharmacokinetics of apigenin.
    Elzayat EM; Shakeel F; Alshehri S; Ibrahim MA; Altamimi MA; Kazi M; Alanazi FK; Haq N
    J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Jun; 1117():58-65. PubMed ID: 30999274
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Automation of ionic liquid enhanced membrane bag-assisted-liquid-phase microextraction with liquid chromatography-tandem mass spectrometry for determination of glucocorticoids in water.
    Goh SXL; Goh HA; Lee HK
    Anal Chim Acta; 2018 Dec; 1035():77-86. PubMed ID: 30224147
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Validation and clinical application of a multiplex high performance liquid chromatography - tandem mass spectrometry assay for the monitoring of plasma concentrations of 12 antibiotics in patients with severe bacterial infections.
    Decosterd LA; Mercier T; Ternon B; Cruchon S; Guignard N; Lahrichi S; Pesse B; Rochat B; Burger R; Lamoth F; Pagani JL; Eggimann P; Csajka C; Choong E; Buclin T; Widmer N; André P; Marchetti O
    J Chromatogr B Analyt Technol Biomed Life Sci; 2020 Nov; 1157():122160. PubMed ID: 32891946
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of a newly developed high performance liquid chromatography method with diode array detection to a liquid chromatography tandem mass spectrometry method for the quantification of cabozantinib, dabrafenib, nilotinib and osimertinib in human serum - Application to therapeutic drug monitoring.
    Aghai-Trommeschlaeger F; Zimmermann S; Gesierich A; Kalogirou C; Goebeler ME; Jung P; Pelzer T; Kurlbaum M; Klinker H; Isberner N; Scherf-Clavel O
    Clin Biochem; 2022; 105-106():35-43. PubMed ID: 35483452
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Mycophenolic acid quantification in human peripheral blood mononuclear cells using liquid chromatography-tandem mass spectrometry.
    Nguyen Thi MT; Capron A; Mourad M; Wallemacq P
    Clin Biochem; 2013 Dec; 46(18):1909-11. PubMed ID: 24060731
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.