118 related articles for article (PubMed ID: 38039044)
1. Assessment of quantitative zonal parameters of prostate gland in discrimination of normal, benign, and malignant conditions: are these the more reliable parameters in the diagnosis of prostate cancer?
Karaca L; Özdemir ZM; Kahraman A; Çelik H; Kaya S
Eur Rev Med Pharmacol Sci; 2023 Nov; 27(22):11122-11130. PubMed ID: 38039044
[TBL] [Abstract][Full Text] [Related]
2. Arterial input function for quantitative dynamic contrast-enhanced MRI to diagnose prostate cancer.
Ziayee F; Mueller-Lutz A; Gross J; Ullrich T; Quentin M; Arsov C; Antoch G; Wittsack HJ; Schimmöller L
Diagn Interv Radiol; 2022 Mar; 28(2):108-114. PubMed ID: 35548894
[TBL] [Abstract][Full Text] [Related]
3. Differential diagnosis of prostate cancer and noncancerous tissue in the peripheral zone and central gland using the quantitative parameters of DCE-MRI: A meta-analysis.
Gao P; Shi C; Zhao L; Zhou Q; Luo L
Medicine (Baltimore); 2016 Dec; 95(52):e5715. PubMed ID: 28033274
[TBL] [Abstract][Full Text] [Related]
4. Influence of arterial input function (AIF) on quantitative prostate dynamic contrast-enhanced (DCE) MRI and zonal prostate anatomy.
Ziayee F; Müller-Lutz A; Gross J; Quentin M; Ullrich T; Heusch P; Arsov C; Rabenalt R; Albers P; Antoch G; Wittsack HJ; Schimmöller L
Magn Reson Imaging; 2018 Nov; 53():28-33. PubMed ID: 29902565
[TBL] [Abstract][Full Text] [Related]
5. Quantitative assessment of dynamic
Tau N; Berlin A; Yeung I; Halankar J; Murphy G; Jhaveri KS; Ghai S; Metser U
Br J Radiol; 2019 Feb; 92(1094):20180568. PubMed ID: 30383459
[TBL] [Abstract][Full Text] [Related]
6. Optimized Fast Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Prostate: Effect of Sampling Duration on Pharmacokinetic Parameters.
Othman AE; Falkner F; Martirosian P; Schraml C; Schwentner C; Nickel D; Nikolaou K; Notohamiprodjo M
Invest Radiol; 2016 Feb; 51(2):106-12. PubMed ID: 26447494
[TBL] [Abstract][Full Text] [Related]
7. Impact of qualitative, semi-quantitative, and quantitative analyses of dynamic contrast-enhanced magnet resonance imaging on prostate cancer detection.
Ziayee F; Ullrich T; Blondin D; Irmer H; Arsov C; Antoch G; Quentin M; Schimmöller L
PLoS One; 2021; 16(4):e0249532. PubMed ID: 33819295
[TBL] [Abstract][Full Text] [Related]
8. Differentiating Transition Zone Cancers From Benign Prostatic Hyperplasia by Quantitative Multiparametric Magnetic Resonance Imaging.
Elbuluk O; Muradyan N; Shih J; Bernardo M; Sankineni S; Merino MJ; Wood BJ; Pinto PA; Choyke PL; Turkbey B
J Comput Assist Tomogr; 2016; 40(2):218-24. PubMed ID: 26760185
[TBL] [Abstract][Full Text] [Related]
9. Comparison of different population-averaged arterial-input-functions in dynamic contrast-enhanced MRI of the prostate: Effects on pharmacokinetic parameters and their diagnostic performance.
Othman AE; Falkner F; Kessler DE; Martirosian P; Weiss J; Kruck S; Kaufmann S; Grimm R; Kramer U; Nikolaou K; Notohamiprodjo M
Magn Reson Imaging; 2016 May; 34(4):496-501. PubMed ID: 26708031
[TBL] [Abstract][Full Text] [Related]
10. Selection of Fitting Model and Arterial Input Function for Repeatability in Dynamic Contrast-Enhanced Prostate MRI.
Peled S; Vangel M; Kikinis R; Tempany CM; Fennessy FM; Fedorov A
Acad Radiol; 2019 Sep; 26(9):e241-e251. PubMed ID: 30467073
[TBL] [Abstract][Full Text] [Related]
11. Morphometric analysis of prostate zonal anatomy using magnetic resonance imaging: impact on age-related changes in patients in Japan and the USA.
Matsugasumi T; Fujihara A; Ushijima S; Kanazawa M; Yamada Y; Shiraishi T; Hongo F; Kamoi K; Okihara K; de Castro Abreu AL; Oishi M; Shin T; Palmer S; Gill IS; Ukimura O
BJU Int; 2017 Oct; 120(4):497-504. PubMed ID: 28220583
[TBL] [Abstract][Full Text] [Related]
12. Can DCE-MRI reduce the number of PI-RADS v.2 false positive findings? Role of quantitative pharmacokinetic parameters in prostate lesions characterization.
Cristel G; Esposito A; Damascelli A; Briganti A; Ambrosi A; Brembilla G; Brunetti L; Antunes S; Freschi M; Montorsi F; Del Maschio A; De Cobelli F
Eur J Radiol; 2019 Sep; 118():51-57. PubMed ID: 31439258
[TBL] [Abstract][Full Text] [Related]
13. Association of prostate zonal volume with location and aggressiveness of clinically significant prostate cancer: A multiparametric MRI study according to PI-RADS version 2.1.
Yang L; Li M; Zhang MN; Yao J; Song B
Eur J Radiol; 2022 May; 150():110268. PubMed ID: 35344914
[TBL] [Abstract][Full Text] [Related]
14. DCE-MRI of the prostate using shutter-speed vs. Tofts model for tumor characterization and assessment of aggressiveness.
Hectors SJ; Besa C; Wagner M; Jajamovich GH; Haines GK; Lewis S; Tewari A; Rastinehad A; Huang W; Taouli B
J Magn Reson Imaging; 2017 Sep; 46(3):837-849. PubMed ID: 28092414
[TBL] [Abstract][Full Text] [Related]
15. Multiparametric magnetic resonance imaging characteristics of normal, benign and malignant conditions in the prostate.
De Visschere PJ; Vral A; Perletti G; Pattyn E; Praet M; Magri V; Villeirs GM
Eur Radiol; 2017 May; 27(5):2095-2109. PubMed ID: 27491874
[TBL] [Abstract][Full Text] [Related]
16. Diagnostic value of semi-quantitative and quantitative analysis of functional parameters in multiparametric MRI of the prostate.
Hauth E; Halbritter D; Jaeger H; Hohmuth H; Beer M
Br J Radiol; 2017 Oct; 90(1078):20170067. PubMed ID: 28749167
[TBL] [Abstract][Full Text] [Related]
17. Patient-specific pharmacokinetic parameter estimation on dynamic contrast-enhanced MRI of prostate: Preliminary evaluation of a novel AIF-free estimation method.
Ginsburg SB; Taimen P; Merisaari H; Vainio P; Boström PJ; Aronen HJ; Jambor I; Madabhushi A
J Magn Reson Imaging; 2016 Dec; 44(6):1405-1414. PubMed ID: 27285161
[TBL] [Abstract][Full Text] [Related]
18. The role of gadolinium in magnetic resonance imaging for early prostate cancer diagnosis: A diagnostic accuracy study.
Cosma I; Tennstedt-Schenk C; Winzler S; Psychogios MN; Pfeil A; Teichgraeber U; Malich A; Papageorgiou I
PLoS One; 2019; 14(12):e0227031. PubMed ID: 31869380
[TBL] [Abstract][Full Text] [Related]
19. The Utility of Diffusion-Weighted Imaging and Perfusion Magnetic Resonance Imaging Parameters for Detecting Clinically Significant Prostate Cancer.
Cindil E; Oner Y; Sendur HN; Ozdemir H; Gazel E; Tunc L; Cerit MN
Can Assoc Radiol J; 2019 Nov; 70(4):441-451. PubMed ID: 31561925
[TBL] [Abstract][Full Text] [Related]
20. Dynamic Contrast-Enhanced MR Perfusion in Differentiation of Benign and Malignant Brain Lesions.
Cetinkaya E; Aralasmak A; Atasoy B; Tokdemir S; Toprak H; Toprak A; Kurtcan S; Alkan A
Curr Med Imaging; 2022; 18(10):1099-1105. PubMed ID: 35331119
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]