These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 38052716)

  • 21. Complications After Self-expanding Transcatheter or Surgical Aortic Valve Replacement.
    Conte JV; Hermiller J; Resar JR; Deeb GM; Gleason TG; Adams DH; Popma JJ; Yakubov SJ; Watson D; Guo J; Zorn GL; Reardon MJ
    Semin Thorac Cardiovasc Surg; 2017 Autumn; 29(3):321-330. PubMed ID: 29195573
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Complications after Transfemoral Transcatheter Aortic Valve Replacement with a Balloon-Expandable Prosthesis: The Importance of Preventative Measures and Contingency Planning.
    Chakravarty T; Jilaihawi H; Doctor N; Fontana G; Forrester JS; Cheng W; Makkar R
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):E29-E42. PubMed ID: 23436313
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Hemodynamic support with Impella ventricular assist device in patients undergoing TAVI: A single center experience.
    Almalla M; Kersten A; Altiok E; Marx N; Schröder JW
    Catheter Cardiovasc Interv; 2020 Feb; 95(3):357-362. PubMed ID: 31268621
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of SAPIEN 3 Transcatheter Valve Implantation on Health Status in Patients With Severe Aortic Stenosis at Intermediate Surgical Risk: Results From the PARTNER S3i Trial.
    Baron SJ; Thourani VH; Kodali S; Arnold SV; Wang K; Magnuson EA; Pichard AD; Babaliaros V; George I; Miller DC; Tuzcu EM; Greason K; Herrmann HC; Smith CR; Leon MB; Cohen DJ;
    JACC Cardiovasc Interv; 2018 Jun; 11(12):1188-1198. PubMed ID: 29860075
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Application of Impella Mechanical Circulatory Support Devices in Transcatheter Aortic Valve Replacement and Balloon Aortic Valvuloplasty: A Single-Center Experience.
    Almajed MR; Mahmood S; Obri M; Nona P; Gonzalez PE; Chiang M; Wang DD; Frisoli T; Lee J; Basir M; O'Neill B; O'Neill W; Villablanca P
    Cardiovasc Revasc Med; 2023 Aug; 53():1-7. PubMed ID: 37012106
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Procedural and 30-day clinical outcomes following transcatheter aortic valve replacement with lotus valve: Results of the RELEVANT study.
    Montone RA; Testa L; Fraccaro C; Montorfano M; Castriota F; Nerla R; Angelillis M; Tusa M; Giannini F; Garatti A; Tarantini G; Petronio AS; Brambilla N; Bedogni F
    Catheter Cardiovasc Interv; 2017 Dec; 90(7):1206-1211. PubMed ID: 28145039
    [TBL] [Abstract][Full Text] [Related]  

  • 27. 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial.
    Abdel-Wahab M; Landt M; Neumann FJ; Massberg S; Frerker C; Kurz T; Kaur J; Toelg R; Sachse S; Jochheim D; Schäfer U; El-Mawardy M; Robinson DR; Richardt G;
    JACC Cardiovasc Interv; 2020 May; 13(9):1071-1082. PubMed ID: 32305398
    [TBL] [Abstract][Full Text] [Related]  

  • 28. When to SAVR in the age of TAVR? A perspective on surgical aortic valve replacement in 2018.
    Wyler von Ballmoos MC; Barker CM; Reul RM; Dadu R; Ramchandani M; Kleiman NS; Reardon MJ
    Cardiovasc Revasc Med; 2018 Mar; 19(2):139-141. PubMed ID: 29661491
    [No Abstract]   [Full Text] [Related]  

  • 29. Commissural Alignment of Bioprosthetic Aortic Valve and Native Aortic Valve Following Surgical and Transcatheter Aortic Valve Replacement and its Impact on Valvular Function and Coronary Filling.
    Fuchs A; Kofoed KF; Yoon SH; Schaffner Y; Bieliauskas G; Thyregod HG; Makkar R; Søndergaard L; De Backer O; Bapat V
    JACC Cardiovasc Interv; 2018 Sep; 11(17):1733-1743. PubMed ID: 30121280
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Transcarotid Approach for Transcatheter Aortic Valve Replacement With the Sapien 3 Prosthesis: A Multicenter French Registry.
    Overtchouk P; Folliguet T; Pinaud F; Fouquet O; Pernot M; Bonnet G; Hubert M; Lapeze J; Claudel JP; Ghostine S; Azmoun A; Caussin C; Zannis K; Harmouche M; Verhoye JP; Lafont A; Chamandi C; Ruggieri VG; Di Cesare A; Leclercq F; Gandet T; Modine T
    JACC Cardiovasc Interv; 2019 Mar; 12(5):413-419. PubMed ID: 30772290
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Long-Term Outcomes After Transcatheter Aortic Valve-in-Valve Replacement.
    de Freitas Campos Guimarães L; Urena M; Wijeysundera HC; Munoz-Garcia A; Serra V; Benitez LM; Auffret V; Cheema AN; Amat-Santos IJ; Fisher Q; Himbert D; Garcia Del Blanco B; Dager A; Le Breton H; Paradis JM; Dumont E; Pibarot P; Rodés-Cabau J
    Circ Cardiovasc Interv; 2018 Sep; 11(9):e007038. PubMed ID: 30354588
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Transcatheter Replacement of Failed Bioprosthetic Valves: Large Multicenter Assessment of the Effect of Implantation Depth on Hemodynamics After Aortic Valve-in-Valve.
    Simonato M; Webb J; Kornowski R; Vahanian A; Frerker C; Nissen H; Bleiziffer S; Duncan A; Rodés-Cabau J; Attizzani GF; Horlick E; Latib A; Bekeredjian R; Barbanti M; Lefevre T; Cerillo A; Hernández JM; Bruschi G; Spargias K; Iadanza A; Brecker S; Palma JH; Finkelstein A; Abdel-Wahab M; Lemos P; Petronio AS; Champagnac D; Sinning JM; Salizzoni S; Napodano M; Fiorina C; Marzocchi A; Leon M; Dvir D
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27301396
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Impact of small prosthesis size on transcatheter or surgical aortic valve replacement outcomes.
    Salna M; Khalique OK; Chiuzan C; Kurlansky P; Borger MA; Hahn RT; Leon MB; Smith CR; Kodali SK; George I
    Catheter Cardiovasc Interv; 2018 Mar; 91(4):765-773. PubMed ID: 28470996
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Outcome of Patients with Low-Gradient Aortic Stenosis Undergoing Transcatheter or Surgical Aortic Valve Replacement.
    Kugelman N; Jaffe R; Aronson D; Sharoni E; Adawi S; Khader N; Shiran A
    Cardiovasc Revasc Med; 2020 Mar; 21(3):257-262. PubMed ID: 31103371
    [TBL] [Abstract][Full Text] [Related]  

  • 35. 1-Year Results in Patients Undergoing Transcatheter Aortic Valve Replacement With Failed Surgical Bioprostheses.
    Deeb GM; Chetcuti SJ; Reardon MJ; Patel HJ; Grossman PM; Schreiber T; Forrest JK; Bajwa TK; O'Hair DP; Petrossian G; Robinson N; Katz S; Hartman A; Dauerman HL; Schmoker J; Khabbaz K; Watson DR; Yakubov SJ; Oh JK; Li S; Kleiman NS; Adams DH; Popma JJ
    JACC Cardiovasc Interv; 2017 May; 10(10):1034-1044. PubMed ID: 28521921
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Impact of prosthesis-iteration evolution and sizing practice on the incidence of prosthesis-patient mismatch after transcatheter aortic valve replacement.
    Abdelghani M; Allali A; Kaur J; Hemetsberger R; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M
    Catheter Cardiovasc Interv; 2019 Apr; 93(5):971-979. PubMed ID: 30467966
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement: The All-Comers Nordic Aortic Valve Intervention Randomized Clinical Trial.
    Søndergaard L; Steinbrüchel DA; Ihlemann N; Nissen H; Kjeldsen BJ; Petursson P; Ngo AT; Olsen NT; Chang Y; Franzen OW; Engstrøm T; Clemmensen P; Olsen PS; Thyregod HG
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27296202
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration.
    Reul RM; Ramchandani MK; Reardon MJ
    Methodist Debakey Cardiovasc J; 2017; 13(3):132-141. PubMed ID: 29743998
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Durability and Clinical Outcomes of Transcatheter Aortic Valve Replacement for Failed Surgical Bioprostheses.
    Dauerman HL; Deeb GM; O'Hair DP; Waksman R; Yakubov SJ; Kleiman NS; Chetcuti SJ; Hermiller JB; Bajwa T; Khabbaz K; de Marchena E; Salerno T; Dries-Devlin JL; Li S; Popma JJ; Reardon MJ
    Circ Cardiovasc Interv; 2019 Oct; 12(10):e008155. PubMed ID: 31607151
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.
    Mauri V; Reimann A; Stern D; Scherner M; Kuhn E; Rudolph V; Rosenkranz S; Eghbalzadeh K; Friedrichs K; Wahlers T; Baldus S; Madershahian N; Rudolph TK
    JACC Cardiovasc Interv; 2016 Nov; 9(21):2200-2209. PubMed ID: 27832845
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.