These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 38064134)

  • 1. Pressure-adjusted venting eliminates start-up delays and compensates for vertical position of syringe infusion pumps used for microinfusion.
    Weiss M; Wendel-Garcia PD; Cannizzaro V; Grass B; Buehler PK; Kleine-Brueggeney M
    J Clin Monit Comput; 2024 Apr; 38(2):531-538. PubMed ID: 38064134
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the venting principle to reduce start-up delays in syringe infusion pumps used for microinfusions.
    Weiss M; Wendel-Garcia PD; Cannizzaro V; Buehler PK; Kleine-Brueggeney M
    J Clin Monit Comput; 2024 Feb; 38(1):213-220. PubMed ID: 37610525
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of vertical pump position on start-up fluid delivery of syringe pumps used for microinfusion.
    Weiss M; Wendel-Garcia PD; Grass B; Buehler PK; Kleine-Brueggeney M
    Paediatr Anaesth; 2023 Dec; 33(12):1099-1107. PubMed ID: 37668096
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of central venous pressure on fluid delivery during start-up of syringe infusion pumps for microinfusion.
    Weiss M; Wendel-Garcia PD; Cannizzaro V; Buehler PK; Kleine-Brueggeney M
    Paediatr Anaesth; 2023 Oct; 33(10):837-843. PubMed ID: 37403751
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Start-up delays of infusion syringe pumps.
    Neff T; Fischer J; Fehr S; Baenziger O; Weiss M
    Paediatr Anaesth; 2001; 11(5):561-5. PubMed ID: 11696120
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simulation Analysis of Flow Rate Variability During Microinfusions: The Effect of Vertical Displacement and Multidrug Infusion in Conventional Infusion Pumps Versus New Cylinder-Type Infusion Pumps.
    Oh EJ; Hong KY; Lee JH; Kim DK; Cho J; Min JJ
    Anesth Analg; 2022 Jan; 134(1):59-68. PubMed ID: 34517393
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Do antisiphon valves reduce flow irregularities during vertical displacement of infusion pump systems?
    Weiss M; Fischer J; Neff T; Schulz G; Bänziger O
    Anaesth Intensive Care; 2000 Dec; 28(6):680-3. PubMed ID: 11153297
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An in vitro analysis of central venous drug delivery by continuous infusion: the effect of manifold design and port selection.
    Moss DR; Bartels K; Peterfreund GL; Lovich MA; Sims NM; Peterfreund RA
    Anesth Analg; 2009 Nov; 109(5):1524-9. PubMed ID: 19843791
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In-line filter included into the syringe infusion pump assembly reduces flow irregularities.
    Brotschi B; Grass B; Weiss M; Doell C; Bernet V
    Intensive Care Med; 2012 Mar; 38(3):518-22. PubMed ID: 22237747
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting.
    Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M
    Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An analysis of drug delivery dynamics via a pediatric central venous infusion system: quantification of delays in achieving intended doses.
    Bartels K; Moss DR; Peterfreund RA
    Anesth Analg; 2009 Oct; 109(4):1156-61. PubMed ID: 19762743
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Syringe size and flow rate affect drug delivery from syringe pumps.
    Weiss M; Hug MI; Neff T; Fischer J
    Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of a novel flow-controlled syringe infusion pump for precise and continuous drug delivery at low flow rates: a laboratory study.
    Batliner M; Weiss M; Dual SA; Grass B; Meboldt M; Schmid Daners M
    Anaesthesia; 2019 Nov; 74(11):1425-1431. PubMed ID: 31373391
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Disturbance of continuous, pump administration of cardiovascular drugs by hydrostatic pressure].
    Krauskopf KH; Rauscher J; Brandt L
    Anaesthesist; 1996 May; 45(5):449-52. PubMed ID: 8779404
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps.
    Neff SB; Neff TA; Gerber S; Weiss MM
    Eur J Anaesthesiol; 2007 Jul; 24(7):602-8. PubMed ID: 17261217
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Changing the syringe pump: A challenging procedure in critically ill patients.
    Elli S; Mattiussi E; Bambi S; Tupputi S; San Fratello S; De Nunzio A; D'Auria S; Rona R; Fumagalli R; Lucchini A
    J Vasc Access; 2020 Nov; 21(6):868-874. PubMed ID: 32126883
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of syringe size on the performance of infusion pumps at low flow rates.
    Schmidt N; Saez C; Seri I; Maturana A
    Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Infusion pump performance with vertical displacement: effect of syringe pump and assembly type.
    Neff TA; Fischer JE; Schulz G; Baenziger O; Weiss M
    Intensive Care Med; 2001 Jan; 27(1):287-91. PubMed ID: 11280650
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Syringe Pump Performance Maintained with IV Filter Use During Low Flow Rate Delivery for Pediatric Patients.
    Chau DF; Vasilopoulos T; Schoepf M; Zhang C; Fahy BG
    Anesth Analg; 2016 Sep; 123(3):705-14. PubMed ID: 27074895
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Always flush the sampling port before flushing the arterial cannula in pediatric patients.
    Weiss M; Fischer JE; Neff T; Hug MI; Baenziger O
    Acta Anaesthesiol Scand; 2001 Jul; 45(6):729-33. PubMed ID: 11421831
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.