These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 38064846)

  • 1. Systematic analysis of non-intrusive polynomial chaos expansion to determine rotary blood pump performance over the entire operating range.
    Blum C; Steinseifer U; Neidlin M
    Comput Biol Med; 2024 Jan; 168():107772. PubMed ID: 38064846
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Progress in the Novel Pediatric Rotary Blood Pump Sputnik Development.
    Telyshev D; Denisov M; Pugovkin A; Selishchev S; Nesterenko I
    Artif Organs; 2018 Apr; 42(4):432-443. PubMed ID: 29508416
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Results of the Interlaboratory Computational Fluid Dynamics Study of the FDA Benchmark Blood Pump.
    Ponnaluri SV; Hariharan P; Herbertson LH; Manning KB; Malinauskas RA; Craven BA
    Ann Biomed Eng; 2023 Jan; 51(1):253-269. PubMed ID: 36401112
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The deep arbitrary polynomial chaos neural network or how Deep Artificial Neural Networks could benefit from data-driven homogeneous chaos theory.
    Oladyshkin S; Praditia T; Kroeker I; Mohammadi F; Nowak W; Otte S
    Neural Netw; 2023 Sep; 166():85-104. PubMed ID: 37480771
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computational modeling of the Food and Drug Administration's benchmark centrifugal blood pump.
    Good BC; Manning KB
    Artif Organs; 2020 Jul; 44(7):E263-E276. PubMed ID: 31971269
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inter-Laboratory Characterization of the Velocity Field in the FDA Blood Pump Model Using Particle Image Velocimetry (PIV).
    Hariharan P; Aycock KI; Buesen M; Day SW; Good BC; Herbertson LH; Steinseifer U; Manning KB; Craven BA; Malinauskas RA
    Cardiovasc Eng Technol; 2018 Dec; 9(4):623-640. PubMed ID: 30291585
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Haemodynamic Effect of Left Atrial and Left Ventricular Cannulation with a Rapid Speed Modulated Rotary Blood Pump During Rest and Exercise: Investigation in a Numerical Cardiorespiratory Model.
    Wu EL; Fresiello L; Kleinhyer M; Meyns B; Fraser JF; Tansley G; Gregory SD
    Cardiovasc Eng Technol; 2020 Aug; 11(4):350-361. PubMed ID: 32557185
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stochastic simulation of the FDA centrifugal blood pump benchmark.
    Karimi MS; Razzaghi P; Raisee M; Hendrick P; Nourbakhsh A
    Biomech Model Mechanobiol; 2021 Oct; 20(5):1871-1887. PubMed ID: 34191187
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental and Numerical Investigation of an Axial Rotary Blood Pump.
    Schüle CY; Thamsen B; Blümel B; Lommel M; Karakaya T; Paschereit CO; Affeld K; Kertzscher U
    Artif Organs; 2016 Nov; 40(11):E192-E202. PubMed ID: 27087467
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump.
    Arvand A; Hormes M; Reul H
    Artif Organs; 2005 Jul; 29(7):531-40. PubMed ID: 15982281
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modeling and Reducing the Effect of Geometric Uncertainties in Intracranial Aneurysms with Polynomial Chaos Expansion, Data Decomposition, and 4D-Flow MRI.
    Perez-Raya I; Fathi MF; Baghaie A; Sacho R; D'Souza RM
    Cardiovasc Eng Technol; 2021 Apr; 12(2):127-143. PubMed ID: 33415699
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of an Adaptive Polynomial Chaos Expansion on Computationally Expensive Three-Dimensional Cardiovascular Models for Uncertainty Quantification and Sensitivity Analysis.
    Quicken S; Donders WP; van Disseldorp EM; Gashi K; Mees BM; van de Vosse FN; Lopata RG; Delhaas T; Huberts W
    J Biomech Eng; 2016 Dec; 138(12):. PubMed ID: 27636531
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemodynamic response to exercise and head-up tilt of patients implanted with a rotary blood pump: a computational modeling study.
    Lim E; Salamonsen RF; Mansouri M; Gaddum N; Mason DG; Timms DL; Stevens MC; Fraser J; Akmeliawati R; Lovell NH
    Artif Organs; 2015 Feb; 39(2):E24-35. PubMed ID: 25345482
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of Numerically Predicted Shear Stress-dependent Dissipative Losses Within a Rotary Blood Pump.
    Strauch C; Escher A; Wulff S; Kertzscher U; Zimpfer D; Thamsen PU; Granegger M
    ASAIO J; 2021 Oct; 67(10):1148-1158. PubMed ID: 34582408
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A numerical model applied to the simulation of cardiovascular hemodynamics and operating condition of continuous-flow left ventricular assist device.
    Liu H; Liu S; Ma X; Zhang Y
    Math Biosci Eng; 2020 Oct; 17(6):7519-7543. PubMed ID: 33378908
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of Numerical Simulations of Thoracic Aorta Hemodynamics: Comparison with In Vivo Measurements and Stochastic Sensitivity Analysis.
    Boccadifuoco A; Mariotti A; Capellini K; Celi S; Salvetti MV
    Cardiovasc Eng Technol; 2018 Dec; 9(4):688-706. PubMed ID: 30357714
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fluid dynamics aspects of miniaturized axial-flow blood pump.
    Kang C; Huang Q; Li Y
    Biomed Mater Eng; 2014; 24(1):723-9. PubMed ID: 24211957
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noninvasive pulsatile flow estimation for an implantable rotary blood pump.
    Karantonis DM; Cloherty SL; Mason DG; Ayre PJ; Lovell NH
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1018-21. PubMed ID: 18002133
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of pulsatility on the mathematical modeling of rotary blood pumps.
    Pirbodaghi T; Weber A; Carrel T; Vandenberghe S
    Artif Organs; 2011 Aug; 35(8):825-32. PubMed ID: 21793862
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Noninvasive average flow estimation for an implantable rotary blood pump: a new algorithm incorporating the role of blood viscosity.
    Malagutti N; Karantonis DM; Cloherty SL; Ayre PJ; Mason DG; Salamonsen RF; Lovell NH
    Artif Organs; 2007 Jan; 31(1):45-52. PubMed ID: 17209960
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.