BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 38066608)

  • 21. Biomechanical comparison of four different posterior malleolus fixation techniques: A finite element analysis.
    Mansur H; Lucas PPA; Vitorino RC; Barin FR; Freitas A; Battaglion LR; Ramos LS
    Foot Ankle Surg; 2022 Jul; 28(5):570-577. PubMed ID: 34154917
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A novel percutaneous crossed screws fixation in treatment of Day type II crescent fracture-dislocation: A finite element analysis.
    Cai L; Zhang Y; Zheng W; Wang J; Guo X; Feng Y
    J Orthop Translat; 2020 Jan; 20():37-46. PubMed ID: 31908932
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Percutaneous arthrodesis.
    Lauge-Pedersen H
    Acta Orthop Scand Suppl; 2003 Feb; 74(307):I, 1-30. PubMed ID: 12640890
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Finite element analysis of different medial fixation strategies in double-plate osteosynthesis for AO type 33-C2 Femoral fractures.
    Li M; Jiang Y; Wang J; Xu G; Wang D; Li J; Zhang W
    Injury; 2023 Apr; 54 Suppl 2():S86-S94. PubMed ID: 35219538
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanical characteristics of fixation methods for floating pubic symphysis.
    Song W; Zhou D; He Y
    J Orthop Surg Res; 2017 Mar; 12(1):38. PubMed ID: 28270223
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical analysis of different internal fixation methods for special Maisonneuve fracture of the ankle joint based on finite element analysis.
    Wu C; Wang X; Zhang H; Xie S; He J
    Injury; 2023 Aug; 54(8):110917. PubMed ID: 37400327
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Finite element analysis of infra-acetabular screw fixation for the treatment of acetabular posterior column fracture.
    Wang T; Zhao B; Yan J; Shao B; Mu W
    Int Orthop; 2022 Mar; 46(3):623-634. PubMed ID: 34981159
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A Novel Anatomical Locking Guide Plate for Treating Acetabular Transverse Posterior Wall Fracture: A Finite Element Analysis Study.
    Li M; Deng J; Li J; Li Z; Zhang H; Zhao Y; Zhang L; Tang P
    Orthop Surg; 2022 Oct; 14(10):2648-2656. PubMed ID: 36000214
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Thoracic vertebra fixation with a novel screw-plate system based on computed tomography imaging and finite element method.
    Zhang W; Zhao J; Jiang X; Li L; Yu C; Zhao Y; Si H
    Comput Methods Programs Biomed; 2020 Apr; 187():104990. PubMed ID: 31345591
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical evaluation of a healed acetabulum with internal fixators: finite element analysis.
    Duan P; Ding X; Xiong M; Wang P; Xu S; Du W
    J Orthop Surg Res; 2023 Mar; 18(1):251. PubMed ID: 36973727
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biomechanical application of finite elements in the orthopedics of stiff clubfoot.
    Liu W; Li F; He H; Teraili A; Wang X; Wahapu P; Wang C
    BMC Musculoskelet Disord; 2022 Dec; 23(1):1112. PubMed ID: 36544111
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of Biomechanical Characteristics and Pelvic Ring Stability Using Different Fixation Methods to Treat Pubic Symphysis Diastasis: A Finite Element Study.
    Yao F; He Y; Qian H; Zhou D; Li Q
    Medicine (Baltimore); 2015 Dec; 94(49):e2207. PubMed ID: 26656353
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanical evaluation of a second generation headless compression screw for ankle arthrodesis in a cadaver model.
    Somberg AM; Whiteside WK; Nilssen E; Murawski D; Liu W
    Foot Ankle Surg; 2016 Mar; 22(1):50-4. PubMed ID: 26869501
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis.
    Hu P; Wu T; Wang HZ; Qi XZ; Yao J; Cheng XD; Chen W; Zhang YZ
    Orthop Surg; 2019 Apr; 11(2):195-203. PubMed ID: 30895703
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A biomechanical evaluation of three forms of internal fixation used in ankle arthrodesis.
    Dohm MP; Benjamin JB; Harrison J; Szivek JA
    Foot Ankle Int; 1994 Jun; 15(6):297-300. PubMed ID: 8075759
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effect of bone quality on the stability of ankle arthrodesis. A finite element study.
    Alonso-Vázquez A; Lauge-Pedersen H; Lidgren L; Taylor M
    Foot Ankle Int; 2004 Nov; 25(11):840-50. PubMed ID: 15574246
    [TBL] [Abstract][Full Text] [Related]  

  • 37. New fixation method for Pauwels type III femoral neck fracture: a finite element analysis of sliding hip screw, L-shaped, and L-shaped with medial plate.
    Freitas A; Bontempo RL; Azevedo FAR; Battaglion LR; Giordano MN; Barin FR; Giordano V
    Eur J Orthop Surg Traumatol; 2021 Aug; 31(6):1069-1075. PubMed ID: 33389052
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical analysis of posterior fixation techniques in a 360 degrees arthrodesis model.
    Burton D; McIff T; Fox T; Lark R; Asher MA; Glattes RC
    Spine (Phila Pa 1976); 2005 Dec; 30(24):2765-71. PubMed ID: 16371900
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Simultaneous Intraoperative Measurement of Cadaver Ankle and Subtalar Joint Compression During Arthrodesis With Intramedullary Nail, Screws, and Tibiotalocalcaneal Plate.
    Hamid KS; Glisson RR; Morash JG; Matson AP; DeOrio JK
    Foot Ankle Int; 2018 Sep; 39(9):1128-1132. PubMed ID: 29766741
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Ankle fusion stability: a biomechanical comparison of external versus internal fixation.
    Hoover JR; Santrock RD; James WC
    Orthopedics; 2011 Apr; 34(4):. PubMed ID: 21469636
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.