  • 21. Electrosurgery: part II. Technology, applications, and safety of electrosurgical devices.
    Taheri A; Mansoori P; Sandoval LF; Feldman SR; Pearce D; Williford PM
    J Am Acad Dermatol; 2014 Apr; 70(4):607.e1-607.e12. PubMed ID: 24629362
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Loop electrosurgical excision in the peritoneal cavity. Preliminary experience with the rat model.
    Munro MG; Fu YS
    J Reprod Med; 1996 Mar; 41(3):143-8. PubMed ID: 8778410
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Higher currents, greater risks: preventing patient burns at the return-electrode site during high-current electrosurgical procedures.
    ECRI
    Health Devices; 2005 Aug; 34(8):273-9. PubMed ID: 16255231
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Monopolar electrosurgical thermal management for minimizing tissue damage.
    Dodde RE; Gee JS; Geiger JD; Shih AJ
    IEEE Trans Biomed Eng; 2012 Jan; 59(1):167-73. PubMed ID: 21947515
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Characterization of the RF ablation-induced 'oven effect': the importance of background tissue thermal conductivity on tissue heating.
    Liu Z; Ahmed M; Weinstein Y; Yi M; Mahajan RL; Goldberg SN
    Int J Hyperthermia; 2006 Jun; 22(4):327-42. PubMed ID: 16754353
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effect of gelled-pad design on the performance of electrosurgical dispersive electrodes.
    Caruso PM; Pearce JA; DeWitt DP
    J Biomech Eng; 1982 Nov; 104(4):324-9. PubMed ID: 7154653
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A computer simulation of radio-frequency ablation of the endocardium.
    Labonté S
    IEEE Trans Biomed Eng; 1994 Sep; 41(9):883-90. PubMed ID: 7959815
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Prostate heating patterns comparing electrosurgical transurethral resection and vaporization: a prospective randomized study.
    Patel A; Fuchs GJ; Gutiérrez-Aceves J; Ryan TP
    J Urol; 1997 Jan; 157(1):169-72. PubMed ID: 8976243
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The role of thermal feedback in electrosurgical tissue heating.
    Curcie DJ; Craelius W
    Technol Health Care; 1995 Oct; 3(2):111-6. PubMed ID: 8574761
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [A mathematical model of electrosurgical endoscopical polypectomy].
    Belov SV; Savost'ianov SIu
    Med Tekh; 2006; (3):3-7. PubMed ID: 16875135
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Thermal Analysis of the PediaFlow pediatric ventricular assist device.
    Gardiner JM; Wu J; Noh MD; Antaki JF; Snyder TA; Paden DB; Paden BE
    ASAIO J; 2007; 53(1):65-73. PubMed ID: 17237651
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
    Busch MH; Vollmann W; Grönemeyer DH
    Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Gold-tip electrodes--a new "deep lesion" technology for catheter ablation? In vitro comparison of a gold alloy versus platinum-iridium tip electrode ablation catheter.
    Lewalter T; Bitzen A; Wurtz S; Blum R; Schlodder K; Yang A; Lickfett L; Schwab JO; Schrickel JW; Tiemann K; Linhart M; Zima E; Merkely B; Lüderitz B
    J Cardiovasc Electrophysiol; 2005 Jul; 16(7):770-2. PubMed ID: 16050836
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Analysis and control of the current distribution under circular dispersive electrodes.
    Wiley JD; Webster JG
    IEEE Trans Biomed Eng; 1982 May; 29(5):381-5. PubMed ID: 7084970
    [No Abstract]   [Full Text] [Related]  

  • 35. Current density distributions, field distributions and impedance analysis of segmented deep brain stimulation electrodes.
    Wei XF; Grill WM
    J Neural Eng; 2005 Dec; 2(4):139-47. PubMed ID: 16317238
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The efficacy of a two needle electrode technique in percutaneous radiofrequency rhizotomy:An investigational laboratory study in an animal model.
    Derby R; Lee CH
    Pain Physician; 2006 Jul; 9(3):207-13. PubMed ID: 16886029
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Sparking from and ignition of damaged electrosurgical electrode cables.
    Health Devices; 1998 Aug; 27(8):301-3. PubMed ID: 9743903
    [No Abstract]   [Full Text] [Related]  

  • 38. Disposable electrosurgical active handles.
    Health Devices; 1973 Sep; 2(11):256-63. PubMed ID: 4582452
    [No Abstract]   [Full Text] [Related]  

  • 39. FEM numerical model study of electrosurgical dispersive electrode design parameters.
    Pearce JA
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():2559-62. PubMed ID: 26736814
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of electrode thermal conductivity in cardiac radiofrequency catheter ablation: a computational modeling study.
    Schutt D; Berjano EJ; Haemmerich D
    Int J Hyperthermia; 2009 Mar; 25(2):99-107. PubMed ID: 19337910
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]