181 related articles for article (PubMed ID: 38081814)
1. DeepRTAlign: toward accurate retention time alignment for large cohort mass spectrometry data analysis.
Liu Y; Yang Y; Chen W; Shen F; Xie L; Zhang Y; Zhai Y; He F; Zhu Y; Chang C
Nat Commun; 2023 Dec; 14(1):8188. PubMed ID: 38081814
[TBL] [Abstract][Full Text] [Related]
2. Graph-based peak alignment algorithms for multiple liquid chromatography-mass spectrometry datasets.
Wang J; Lam H
Bioinformatics; 2013 Oct; 29(19):2469-76. PubMed ID: 23904508
[TBL] [Abstract][Full Text] [Related]
3. MultiAlign: a multiple LC-MS analysis tool for targeted omics analysis.
LaMarche BL; Crowell KL; Jaitly N; Petyuk VA; Shah AR; Polpitiya AD; Sandoval JD; Kiebel GR; Monroe ME; Callister SJ; Metz TO; Anderson GA; Smith RD
BMC Bioinformatics; 2013 Feb; 14():49. PubMed ID: 23398735
[TBL] [Abstract][Full Text] [Related]
4. Multi-profile Bayesian alignment model for LC-MS data analysis with integration of internal standards.
Tsai TH; Tadesse MG; Di Poto C; Pannell LK; Mechref Y; Wang Y; Ressom HW
Bioinformatics; 2013 Nov; 29(21):2774-80. PubMed ID: 24013927
[TBL] [Abstract][Full Text] [Related]
5. Retention time alignment algorithms for LC/MS data must consider non-linear shifts.
Podwojski K; Fritsch A; Chamrad DC; Paul W; Sitek B; Stühler K; Mutzel P; Stephan C; Meyer HE; Urfer W; Ickstadt K; Rahnenführer J
Bioinformatics; 2009 Mar; 25(6):758-64. PubMed ID: 19176558
[TBL] [Abstract][Full Text] [Related]
6. Shape-based feature matching improves protein identification via LC-MS and tandem MS.
Noy K; Towfic F; Wittenberg GM; Fasulo D
J Comput Biol; 2011 Apr; 18(4):547-57. PubMed ID: 21417940
[TBL] [Abstract][Full Text] [Related]
7. Retention time alignment of LC/MS data by a divide-and-conquer algorithm.
Zhang Z
J Am Soc Mass Spectrom; 2012 Apr; 23(4):764-72. PubMed ID: 22298290
[TBL] [Abstract][Full Text] [Related]
8. Time alignment algorithms based on selected mass traces for complex LC-MS data.
Christin C; Hoefsloot HC; Smilde AK; Suits F; Bischoff R; Horvatovich PL
J Proteome Res; 2010 Mar; 9(3):1483-95. PubMed ID: 20070124
[TBL] [Abstract][Full Text] [Related]
9. Incorporating peak grouping information for alignment of multiple liquid chromatography-mass spectrometry datasets.
Wandy J; Daly R; Breitling R; Rogers S
Bioinformatics; 2015 Jun; 31(12):1999-2006. PubMed ID: 25649621
[TBL] [Abstract][Full Text] [Related]
10. A Simple Method for Peak Alignment Using Relative Retention Time Related to an Inherent Peak in Liquid Chromatography-Mass Spectrometry-Based Metabolomics.
Wang Y; Ma L; Zhang M; Chen M; Li P; He C; Yan C; Wan JB
J Chromatogr Sci; 2019 Jan; 57(1):9-16. PubMed ID: 30084945
[TBL] [Abstract][Full Text] [Related]
11. MassUntangler: a novel alignment tool for label-free liquid chromatography-mass spectrometry proteomic data.
Ballardini R; Benevento M; Arrigoni G; Pattini L; Roda A
J Chromatogr A; 2011 Dec; 1218(49):8859-68. PubMed ID: 21783198
[TBL] [Abstract][Full Text] [Related]
12. Critical assessment of alignment procedures for LC-MS proteomics and metabolomics measurements.
Lange E; Tautenhahn R; Neumann S; Gröpl C
BMC Bioinformatics; 2008 Sep; 9():375. PubMed ID: 18793413
[TBL] [Abstract][Full Text] [Related]
13. Combining peak- and chromatogram-based retention time alignment algorithms for multiple chromatography-mass spectrometry datasets.
Hoffmann N; Keck M; Neuweger H; Wilhelm M; Högy P; Niehaus K; Stoye J
BMC Bioinformatics; 2012 Aug; 13():214. PubMed ID: 22920415
[TBL] [Abstract][Full Text] [Related]
14. G-Aligner: a graph-based feature alignment method for untargeted LC-MS-based metabolomics.
Wang R; Lu M; An S; Wang J; Yu C
BMC Bioinformatics; 2023 Nov; 24(1):431. PubMed ID: 37964228
[TBL] [Abstract][Full Text] [Related]
15. Tutorial: Correction of shifts in single-stage LC-MS(/MS) data.
Mitra V; Smilde AK; Bischoff R; Horvatovich P
Anal Chim Acta; 2018 Jan; 999():37-53. PubMed ID: 29254573
[TBL] [Abstract][Full Text] [Related]
16. Robust algorithm for alignment of liquid chromatography-mass spectrometry analyses in an accurate mass and time tag data analysis pipeline.
Jaitly N; Monroe ME; Petyuk VA; Clauss TR; Adkins JN; Smith RD
Anal Chem; 2006 Nov; 78(21):7397-409. PubMed ID: 17073405
[TBL] [Abstract][Full Text] [Related]
17. Inversion of peak elution order prevents uniform time alignment of complex liquid-chromatography coupled to mass spectrometry datasets.
Mitra V; Smilde A; Hoefsloot H; Suits F; Bischoff R; Horvatovich P
J Chromatogr A; 2014 Dec; 1373():61-72. PubMed ID: 25482036
[TBL] [Abstract][Full Text] [Related]
18. Targeted realignment of LC-MS profiles by neighbor-wise compound-specific graphical time warping with misalignment detection.
Wu CT; Wang Y; Wang Y; Ebbels T; Karaman I; Graça G; Pinto R; Herrington DM; Wang Y; Yu G
Bioinformatics; 2020 May; 36(9):2862-2871. PubMed ID: 31950989
[TBL] [Abstract][Full Text] [Related]
19. Aligning LC peaks by converting gradient retention times to retention index of peptides in proteomic experiments.
Shinoda K; Tomita M; Ishihama Y
Bioinformatics; 2008 Jul; 24(14):1590-5. PubMed ID: 18492686
[TBL] [Abstract][Full Text] [Related]
20. [Application of peptide retention time in proteome research].
Shao C; Gao Y
Se Pu; 2010 Feb; 28(2):128-34. PubMed ID: 20556949
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]