BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 38081814)

  • 1. DeepRTAlign: toward accurate retention time alignment for large cohort mass spectrometry data analysis.
    Liu Y; Yang Y; Chen W; Shen F; Xie L; Zhang Y; Zhai Y; He F; Zhu Y; Chang C
    Nat Commun; 2023 Dec; 14(1):8188. PubMed ID: 38081814
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Graph-based peak alignment algorithms for multiple liquid chromatography-mass spectrometry datasets.
    Wang J; Lam H
    Bioinformatics; 2013 Oct; 29(19):2469-76. PubMed ID: 23904508
    [TBL] [Abstract][Full Text] [Related]  

  • 3. MultiAlign: a multiple LC-MS analysis tool for targeted omics analysis.
    LaMarche BL; Crowell KL; Jaitly N; Petyuk VA; Shah AR; Polpitiya AD; Sandoval JD; Kiebel GR; Monroe ME; Callister SJ; Metz TO; Anderson GA; Smith RD
    BMC Bioinformatics; 2013 Feb; 14():49. PubMed ID: 23398735
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multi-profile Bayesian alignment model for LC-MS data analysis with integration of internal standards.
    Tsai TH; Tadesse MG; Di Poto C; Pannell LK; Mechref Y; Wang Y; Ressom HW
    Bioinformatics; 2013 Nov; 29(21):2774-80. PubMed ID: 24013927
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Retention time alignment algorithms for LC/MS data must consider non-linear shifts.
    Podwojski K; Fritsch A; Chamrad DC; Paul W; Sitek B; Stühler K; Mutzel P; Stephan C; Meyer HE; Urfer W; Ickstadt K; Rahnenführer J
    Bioinformatics; 2009 Mar; 25(6):758-64. PubMed ID: 19176558
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Shape-based feature matching improves protein identification via LC-MS and tandem MS.
    Noy K; Towfic F; Wittenberg GM; Fasulo D
    J Comput Biol; 2011 Apr; 18(4):547-57. PubMed ID: 21417940
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Retention time alignment of LC/MS data by a divide-and-conquer algorithm.
    Zhang Z
    J Am Soc Mass Spectrom; 2012 Apr; 23(4):764-72. PubMed ID: 22298290
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Time alignment algorithms based on selected mass traces for complex LC-MS data.
    Christin C; Hoefsloot HC; Smilde AK; Suits F; Bischoff R; Horvatovich PL
    J Proteome Res; 2010 Mar; 9(3):1483-95. PubMed ID: 20070124
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Incorporating peak grouping information for alignment of multiple liquid chromatography-mass spectrometry datasets.
    Wandy J; Daly R; Breitling R; Rogers S
    Bioinformatics; 2015 Jun; 31(12):1999-2006. PubMed ID: 25649621
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Simple Method for Peak Alignment Using Relative Retention Time Related to an Inherent Peak in Liquid Chromatography-Mass Spectrometry-Based Metabolomics.
    Wang Y; Ma L; Zhang M; Chen M; Li P; He C; Yan C; Wan JB
    J Chromatogr Sci; 2019 Jan; 57(1):9-16. PubMed ID: 30084945
    [TBL] [Abstract][Full Text] [Related]  

  • 11. MassUntangler: a novel alignment tool for label-free liquid chromatography-mass spectrometry proteomic data.
    Ballardini R; Benevento M; Arrigoni G; Pattini L; Roda A
    J Chromatogr A; 2011 Dec; 1218(49):8859-68. PubMed ID: 21783198
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Critical assessment of alignment procedures for LC-MS proteomics and metabolomics measurements.
    Lange E; Tautenhahn R; Neumann S; Gröpl C
    BMC Bioinformatics; 2008 Sep; 9():375. PubMed ID: 18793413
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Combining peak- and chromatogram-based retention time alignment algorithms for multiple chromatography-mass spectrometry datasets.
    Hoffmann N; Keck M; Neuweger H; Wilhelm M; Högy P; Niehaus K; Stoye J
    BMC Bioinformatics; 2012 Aug; 13():214. PubMed ID: 22920415
    [TBL] [Abstract][Full Text] [Related]  

  • 14. G-Aligner: a graph-based feature alignment method for untargeted LC-MS-based metabolomics.
    Wang R; Lu M; An S; Wang J; Yu C
    BMC Bioinformatics; 2023 Nov; 24(1):431. PubMed ID: 37964228
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tutorial: Correction of shifts in single-stage LC-MS(/MS) data.
    Mitra V; Smilde AK; Bischoff R; Horvatovich P
    Anal Chim Acta; 2018 Jan; 999():37-53. PubMed ID: 29254573
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Robust algorithm for alignment of liquid chromatography-mass spectrometry analyses in an accurate mass and time tag data analysis pipeline.
    Jaitly N; Monroe ME; Petyuk VA; Clauss TR; Adkins JN; Smith RD
    Anal Chem; 2006 Nov; 78(21):7397-409. PubMed ID: 17073405
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Inversion of peak elution order prevents uniform time alignment of complex liquid-chromatography coupled to mass spectrometry datasets.
    Mitra V; Smilde A; Hoefsloot H; Suits F; Bischoff R; Horvatovich P
    J Chromatogr A; 2014 Dec; 1373():61-72. PubMed ID: 25482036
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Targeted realignment of LC-MS profiles by neighbor-wise compound-specific graphical time warping with misalignment detection.
    Wu CT; Wang Y; Wang Y; Ebbels T; Karaman I; Graça G; Pinto R; Herrington DM; Wang Y; Yu G
    Bioinformatics; 2020 May; 36(9):2862-2871. PubMed ID: 31950989
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Aligning LC peaks by converting gradient retention times to retention index of peptides in proteomic experiments.
    Shinoda K; Tomita M; Ishihama Y
    Bioinformatics; 2008 Jul; 24(14):1590-5. PubMed ID: 18492686
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Application of peptide retention time in proteome research].
    Shao C; Gao Y
    Se Pu; 2010 Feb; 28(2):128-34. PubMed ID: 20556949
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.