127 related articles for article (PubMed ID: 38082825)
1. Overcoming the Impedance Range Limitations of Portable Bioelectrical Impedance Spectroscopy Clinical Devices.
Montalibet A; Massot B; Gehin C; McAdams E
Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-4. PubMed ID: 38082825
[TBL] [Abstract][Full Text] [Related]
2. Measurement errors in multifrequency bioelectrical impedance analyzers with and without impedance electrode mismatch.
Bogónez-Franco P; Nescolarde L; Bragós R; Rosell-Ferrer J; Yandiola I
Physiol Meas; 2009 Jul; 30(7):573-87. PubMed ID: 19491458
[TBL] [Abstract][Full Text] [Related]
3. Development of a Segmental Bioelectrical Impedance Spectroscopy Device for Body Composition Measurement.
Cannon T; Choi J
Sensors (Basel); 2019 Nov; 19(22):. PubMed ID: 31698709
[TBL] [Abstract][Full Text] [Related]
4. Cross-sectional and longitudinal agreement between two multifrequency bioimpedance devices for resistance, reactance, and phase angle values.
Tinsley GM; Moore ML; Silva AM; Sardinha LB
Eur J Clin Nutr; 2020 Jun; 74(6):900-911. PubMed ID: 31455876
[TBL] [Abstract][Full Text] [Related]
5. A Practical Method to Reduce Electrode Mismatch Artefacts during 4-electrode BioImpedance Spectroscopy Measurements.
Montalibet A; McAdams E
Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():5775-5779. PubMed ID: 30441648
[TBL] [Abstract][Full Text] [Related]
6. Agreement of bioelectrical resistance, reactance, and phase angle values from supine and standing bioimpedance analyzers.
Dellinger JR; Johnson BA; Benavides ML; Moore ML; Stratton MT; Harty PS; Siedler MR; Tinsley GM
Physiol Meas; 2021 Apr; 42(3):. PubMed ID: 33592586
[No Abstract] [Full Text] [Related]
7. Lack of agreement of in vivo raw bioimpedance measurements obtained from two single and multi-frequency bioelectrical impedance devices.
Silva AM; Matias CN; Nunes CL; Santos DA; Marini E; Lukaski HC; Sardinha LB
Eur J Clin Nutr; 2019 Jul; 73(7):1077-1083. PubMed ID: 30349141
[TBL] [Abstract][Full Text] [Related]
8. Bioimpedance in the assessment of unilateral lymphedema of a limb: the optimal frequency.
Gaw R; Box R; Cornish B
Lymphat Res Biol; 2011; 9(2):93-9. PubMed ID: 21688978
[TBL] [Abstract][Full Text] [Related]
9. Different displacement of bioimpedance vector due to Ag/AgCl electrode effect.
Nescolarde L; Lukaski H; De Lorenzo A; de-Mateo-Silleras B; Redondo-Del-Río MP; Camina-Martín MA
Eur J Clin Nutr; 2016 Dec; 70(12):1401-1407. PubMed ID: 27380885
[TBL] [Abstract][Full Text] [Related]
10. Assessment of bioimpedance spectroscopy devices: a comparative study and error analysis of gold-plated copper electrodes.
Mussnig S; Krenn S; Hecking M; Wabel P
Physiol Meas; 2024 Feb; 45(2):. PubMed ID: 38237199
[No Abstract] [Full Text] [Related]
11. Multifrequency right-side, localized and segmental BIA obtained with different bioimpedance analysers.
Bogónez-Franco P; Nescolarde L; McAdams E; Rosell-Ferrer J
Physiol Meas; 2015 Jan; 36(1):85-106. PubMed ID: 25501588
[TBL] [Abstract][Full Text] [Related]
12. Textrode functional straps for bioimpedance measurements--experimental results for body composition analysis.
Márquez JC; Seoane F; Lindecrantz K
Eur J Clin Nutr; 2013 Jan; 67 Suppl 1():S22-7. PubMed ID: 23299868
[TBL] [Abstract][Full Text] [Related]
13. A Thorax Simulator for Complex Dynamic Bioimpedance Measurements With Textile Electrodes.
Ulbrich M; Muhlsteff J; Teichmann D; Leonhardt S; Walter M
IEEE Trans Biomed Circuits Syst; 2015 Jun; 9(3):412-20. PubMed ID: 25148671
[TBL] [Abstract][Full Text] [Related]
14. Alternate Electrode Positions for the Measurement of Hand Volumes Using Bioimpedance Spectroscopy.
Edwick DO; Hince DA; Rawlins JM; Wood FM; Edgar DW
Lymphat Res Biol; 2020 Dec; 18(6):560-571. PubMed ID: 32456535
[No Abstract] [Full Text] [Related]
15. Estimating Localized Bio-impedance with Measures from Multiple Redundant Electrode Configurations.
Fu B; Freeborn TJ
Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():4351-4354. PubMed ID: 30441317
[TBL] [Abstract][Full Text] [Related]
16. Body Positional Effects on Bioimpedance Spectroscopy Measurements for Lymphedema Assessment of the Arm.
Koelmeyer LA; Ward LC; Dean C; Boyages J
Lymphat Res Biol; 2020 Oct; 18(5):464-473. PubMed ID: 32027213
[No Abstract] [Full Text] [Related]
17. Textile electrode straps for wrist-to-ankle bioimpedance measurements for Body Composition Analysis. Initial validation & experimental results.
Marquez JC; Ferreira J; Seoane F; Buendia R; Lindecrantz K
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():6385-8. PubMed ID: 21096699
[TBL] [Abstract][Full Text] [Related]
18. Wrist-wearable bioelectrical impedance analyzer with miniature electrodes for daily obesity management.
Jung MH; Namkoong K; Lee Y; Koh YJ; Eom K; Jang H; Jung W; Bae J; Park J
Sci Rep; 2021 Jan; 11(1):1238. PubMed ID: 33441675
[TBL] [Abstract][Full Text] [Related]
19. Longitudinal agreement of four bioimpedance analyzers for detecting changes in raw bioimpedance during purposeful weight gain with resistance training.
Stratton MT; Smith RW; Harty PS; Rodriguez C; Johnson BA; Dellinger JR; Williams AD; White SJ; Benavides ML; Tinsley GM
Eur J Clin Nutr; 2021 Jul; 75(7):1060-1068. PubMed ID: 33727706
[TBL] [Abstract][Full Text] [Related]
20. Influence of the type of electrodes in the assessment of body composition by bioelectrical impedance analysis in the supine position.
Dupertuis YM; Pereira AG; Karsegard VL; Hemmer A; Biolley E; Collet TH; Genton L
Clin Nutr; 2022 Nov; 41(11):2455-2463. PubMed ID: 36215865
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]