BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 38097928)

  • 1. Performance analysis of conventional and AI-based variant callers using short and long reads.
    Abdelwahab O; Belzile F; Torkamaneh D
    BMC Bioinformatics; 2023 Dec; 24(1):472. PubMed ID: 38097928
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Haplotype-aware variant calling with PEPPER-Margin-DeepVariant enables high accuracy in nanopore long-reads.
    Shafin K; Pesout T; Chang PC; Nattestad M; Kolesnikov A; Goel S; Baid G; Kolmogorov M; Eizenga JM; Miga KH; Carnevali P; Jain M; Carroll A; Paten B
    Nat Methods; 2021 Nov; 18(11):1322-1332. PubMed ID: 34725481
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Long-Read Sequencing Approach for Direct Haplotype Phasing in Clinical Settings.
    Maestri S; Maturo MG; Cosentino E; Marcolungo L; Iadarola B; Fortunati E; Rossato M; Delledonne M
    Int J Mol Sci; 2020 Dec; 21(23):. PubMed ID: 33271988
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Benchmarking variant callers in next-generation and third-generation sequencing analysis.
    Pei S; Liu T; Ren X; Li W; Chen C; Xie Z
    Brief Bioinform; 2021 May; 22(3):. PubMed ID: 32698196
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Local read haplotagging enables accurate long-read small variant calling.
    Kolesnikov A; Cook D; Nattestad M; McNulty B; Gorzynski J; Goenka S; Ashley EA; Jain M; Miga KH; Paten B; Chang PC; Carroll A; Shafin K
    bioRxiv; 2023 Sep; ():. PubMed ID: 37745389
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluating the performance of low-frequency variant calling tools for the detection of variants from short-read deep sequencing data.
    Xiang X; Lu B; Song D; Li J; Shu K; Pu D
    Sci Rep; 2023 Nov; 13(1):20444. PubMed ID: 37993475
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Highly accurate long reads are crucial for realizing the potential of biodiversity genomics.
    Hotaling S; Wilcox ER; Heckenhauer J; Stewart RJ; Frandsen PB
    BMC Genomics; 2023 Mar; 24(1):117. PubMed ID: 36927511
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Benchmarking datasets for assembly-based variant calling using high-fidelity long reads.
    Lee H; Kim J; Lee J
    BMC Genomics; 2023 Mar; 24(1):148. PubMed ID: 36973656
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Longshot enables accurate variant calling in diploid genomes from single-molecule long read sequencing.
    Edge P; Bansal V
    Nat Commun; 2019 Oct; 10(1):4660. PubMed ID: 31604920
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Systematic benchmark of state-of-the-art variant calling pipelines identifies major factors affecting accuracy of coding sequence variant discovery.
    Barbitoff YA; Abasov R; Tvorogova VE; Glotov AS; Predeus AV
    BMC Genomics; 2022 Feb; 23(1):155. PubMed ID: 35193511
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the Available Variant Calling Tools for Oxford Nanopore Sequencing in Breast Cancer.
    Helal AA; Saad BT; Saad MT; Mosaad GS; Aboshanab KM
    Genes (Basel); 2022 Sep; 13(9):. PubMed ID: 36140751
    [TBL] [Abstract][Full Text] [Related]  

  • 12. ECNano: A cost-effective workflow for target enrichment sequencing and accurate variant calling on 4800 clinically significant genes using a single MinION flowcell.
    Leung AW; Leung HC; Wong CL; Zheng ZX; Lui WW; Luk HM; Lo IF; Luo R; Lam TW
    BMC Med Genomics; 2022 Mar; 15(1):43. PubMed ID: 35246132
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance assessment of variant calling pipelines using human whole exome sequencing and simulated data.
    Kumaran M; Subramanian U; Devarajan B
    BMC Bioinformatics; 2019 Jun; 20(1):342. PubMed ID: 31208315
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Short and long-read genome sequencing methodologies for somatic variant detection; genomic analysis of a patient with diffuse large B-cell lymphoma.
    Roberts HE; Lopopolo M; Pagnamenta AT; Sharma E; Parkes D; Lonie L; Freeman C; Knight SJL; Lunter G; Dreau H; Lockstone H; Taylor JC; Schuh A; Bowden R; Buck D
    Sci Rep; 2021 Mar; 11(1):6408. PubMed ID: 33742045
    [TBL] [Abstract][Full Text] [Related]  

  • 15. SInC: an accurate and fast error-model based simulator for SNPs, Indels and CNVs coupled with a read generator for short-read sequence data.
    Pattnaik S; Gupta S; Rao AA; Panda B
    BMC Bioinformatics; 2014 Feb; 15():40. PubMed ID: 24495296
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Benchmarking multi-platform sequencing technologies for human genome assembly.
    Wang J; Veldsman WP; Fang X; Huang Y; Xie X; Lyu A; Zhang L
    Brief Bioinform; 2023 Sep; 24(5):. PubMed ID: 37594299
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Short-read aligner performance in germline variant identification.
    Wilton R; Szalay AS
    Bioinformatics; 2023 Aug; 39(8):. PubMed ID: 37527006
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sensitive alignment using paralogous sequence variants improves long-read mapping and variant calling in segmental duplications.
    Prodanov T; Bansal V
    Nucleic Acids Res; 2020 Nov; 48(19):e114. PubMed ID: 33035301
    [TBL] [Abstract][Full Text] [Related]  

  • 19. RDscan: A New Method for Improving Germline and Somatic Variant Calling Based on Read Depth Distribution.
    Lee S; Hong S; Woo J; Lee JH; Kim K; Kim L; Park K; Jung J
    J Comput Biol; 2022 Sep; 29(9):987-1000. PubMed ID: 35749140
    [TBL] [Abstract][Full Text] [Related]  

  • 20. NanoSim: nanopore sequence read simulator based on statistical characterization.
    Yang C; Chu J; Warren RL; Birol I
    Gigascience; 2017 Apr; 6(4):1-6. PubMed ID: 28327957
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.