These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 3810211)

  • 1. Heat of intramedullary reaming.
    Henry SL; Adcock RA; Von Fraunhofer JA; Seligson D
    South Med J; 1987 Feb; 80(2):173-6. PubMed ID: 3810211
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of the size and condition of the reamers on bone temperature during intramedullary reaming.
    García OG; Mombiela FL; De La Fuente CJ; Aránguez MG; Escribano DV; Martín JV
    J Bone Joint Surg Am; 2004 May; 86(5):994-9. PubMed ID: 15118043
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Heat-induced segmental necrosis after reaming of one humeral and two tibial fractures with a narrow medullary canal.
    Ochsner PE; Baumgart F; Kohler G
    Injury; 1998; 29 Suppl 2():B1-10. PubMed ID: 10341889
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intramedullary pressure increase and increase in cortical temperature during reaming of the femoral medullary cavity: the effect of draining the medullary contents before reaming.
    Mueller CA; Rahn BA
    J Trauma; 2003 Sep; 55(3):495-503; discussion 503. PubMed ID: 14501893
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Temperature rise during reamed tibial nailing.
    Giannoudis PV; Snowden S; Matthews SJ; Smye SW; Smith RM
    Clin Orthop Relat Res; 2002 Feb; (395):255-61. PubMed ID: 11937890
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The thermal effects of intramedullary reaming.
    Karunakar MA; Frankenburg EP; Le TT; Hall J
    J Orthop Trauma; 2004; 18(10):674-9. PubMed ID: 15507820
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reduction of temperatures generated by the triple reamer within the femoral head.
    Calder SJ; Barnes MR; Harper WM
    Injury; 1995 Apr; 26(3):183-5. PubMed ID: 7744475
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The physics of heat generation during reaming of the medullary cavity.
    Baumgart F; Kohler G; Ochsner PE
    Injury; 1998; 29 Suppl 2():B11-25. PubMed ID: 10341890
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cortical heat generation using an irrigating/aspirating single-pass reaming vs conventional stepwise reaming.
    Higgins TF; Casey V; Bachus K
    J Orthop Trauma; 2007 Mar; 21(3):192-7. PubMed ID: 17473756
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intramedullary pressure, strain on the diaphysis and increase in cortical temperature when reaming the femoral medullary cavity--a comparison of blunt and sharp reamers.
    Müller C; McIff T; Rahn BA; Pfister U; Weller S
    Injury; 1993; 24 Suppl 3():S22-30. PubMed ID: 8168872
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiopulmonary response to reamed intramedullary nailing of the femur comparing traditional reaming with a one-step reamer-irrigator-aspirator reaming system: an experimental study in pigs.
    Husebye EE; Lyberg T; Opdahl H; Laurvik H; Røise O
    J Trauma; 2010 Oct; 69(4):E6-14. PubMed ID: 20489666
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does graded reaming affect the composition of reaming products in intramedullary nailing of long bones?
    Kouzelis AT; Kourea H; Megas P; Panagiotopoulos E; Marangos M; Lambiris E
    Orthopedics; 2004 Aug; 27(8):852-6. PubMed ID: 15369007
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The assessment of cortical heat during intramedullary reaming of long bones.
    Frölke JP; Peters R; Boshuizen K; Patka P; Bakker FC; Haarman HJ
    Injury; 2001 Nov; 32(9):683-8. PubMed ID: 11600113
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A cadaver model evaluating femoral intramedullary reaming: a comparison between new reamer design (Pressure Sentinel) and a novel suction/irrigation reamer (RIA).
    Goplen G; Wilson JA; McAffrey M; Deluzio K; Leighton R
    Injury; 2010 Nov; 41 Suppl 2():S38-42. PubMed ID: 21144925
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of reaming debris at the fracture gap of diaphyseal A3 femur fractures after reamed intramedullary nailing and using an intramedullary application system.
    Hoegel FW; Abdulazim AN; Buehren V; Augat P
    J Trauma; 2010 Dec; 69(6):E98-101. PubMed ID: 20130488
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fracture healing after reamed and unreamed intramedullary nailing in sheep tibia.
    Högel F; Schlegel U; Südkamp N; Müller C
    Injury; 2011 Jul; 42(7):667-74. PubMed ID: 21074768
    [TBL] [Abstract][Full Text] [Related]  

  • 17. "Push-past" reaming as a reduction aid with intramedullary nailing of metadiaphyseal and diaphyseal femoral shaft fractures.
    Gary JL; Munz JW; Burgess AR
    Orthopedics; 2014 Jun; 37(6):393-6. PubMed ID: 24972428
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Thermal necrosis complicating reamed intramedullary nailing of a closed tibial diaphysis fracture: a case report.
    Saldua NS; Kuhn KM; Mazurek MT
    J Orthop Trauma; 2008; 22(10):737-41. PubMed ID: 18978551
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of intramedullary reaming on a diaphyseal bone defect of the tibia.
    Kuzyk PR; Li R; Zdero R; Davies JE; Schemitsch EH
    J Trauma; 2011 May; 70(5):1248-56. PubMed ID: 20805760
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intramedullary Tibial Nailing Reduces the Attachment Area and Ultimate Load of the Anterior Medial Meniscal Root: A Potential Explanation for Anterior Knee Pain in Female Patients and Smaller Patients.
    LaPrade MD; LaPrade CM; Hamming MG; Ellman MB; Turnbull TL; Rasmussen MT; Wijdicks CA; LaPrade RF
    Am J Sports Med; 2015 Jul; 43(7):1670-5. PubMed ID: 25911417
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.