These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 38109805)

  • 21. Internal and External Pipe Defect Characterization via High-Frequency Lamb Waves Generated by Unidirectional EMAT.
    Zhang X; Li B; Zhang X; Song X; Tu J; Cai C; Yuan J; Wu Q
    Sensors (Basel); 2023 Oct; 23(21):. PubMed ID: 37960540
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Extending the Incidence Angle of Shear Vertical Wave Electromagnetic Acoustic Transducer with Horizontal Magnetization.
    Qu Z; Li Z; Yang R; Hu S; Wang S
    Sensors (Basel); 2022 Nov; 22(22):. PubMed ID: 36433185
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A New Design of the Dual-Mode and Pure Longitudinal EMAT by Using a Radial-Flux-Focusing Magnet.
    Zhang X; Li W; Li B; Tu J; Liao C; Wu Q; Feng S; Song X
    Sensors (Basel); 2022 Feb; 22(4):. PubMed ID: 35214222
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A novel laser-EMAT ultrasonic longitudinal wave resonance method for wall thickness measurement at high temperatures.
    Chen W; Lu C; Li X; Shi W; Zhou Y; Liu Y; Zhang S
    Ultrasonics; 2024 Jul; 141():107340. PubMed ID: 38744113
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Application of Pulse Compression Technique in High-Temperature Carbon Steel Forgings Crack Detection with Angled SV-Wave EMATs.
    He M; Shi W; Lu C; Chen G; Qiu F; Zhu Y; Liu Y
    Sensors (Basel); 2023 Mar; 23(5):. PubMed ID: 36904887
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A study of internal defect testing with the laser-EMAT ultrasonic method.
    Pei C; Fukuchi T; Zhu H; Koyama K; Demachi K; Uesaka M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Dec; 59(12):2702-8. PubMed ID: 23221219
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Bolt axial stress measurement based on a mode-converted ultrasound method using an electromagnetic acoustic transducer.
    Ding X; Wu X; Wang Y
    Ultrasonics; 2014 Mar; 54(3):914-20. PubMed ID: 24289900
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Signal enhancement in Rayleigh wave interactions using a laser-ultrasound/EMAT imaging system.
    Boonsang S; Dewhurst RJ
    Ultrasonics; 2005 Jun; 43(7):512-23. PubMed ID: 15950025
    [TBL] [Abstract][Full Text] [Related]  

  • 29. PPM EMAT for Defect Detection in 90-Degree Pipe Bend.
    Wang L; Xu J; Chen D
    Materials (Basel); 2022 Jul; 15(13):. PubMed ID: 35806754
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Characterizing Halbach EMAT Configurations for SH0 Ultrasonic Waves.
    Shankar S; Balasubramaniam K
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 May; 68(5):1866-1875. PubMed ID: 33406039
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A combination of PZT and EMAT transducers for interface inspection.
    Na WB; Kundu T
    J Acoust Soc Am; 2002 May; 111(5 Pt 1):2128-39. PubMed ID: 12051433
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Conventional electromagnetic acoustic transducer development for optimum Lamb wave modes.
    Murayama R; Mizutani K
    Ultrasonics; 2002 May; 40(1-8):491-5. PubMed ID: 12159989
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A new omni-directional EMAT for ultrasonic Lamb wave tomography imaging of metallic plate defects.
    Huang S; Wei Z; Zhao W; Wang S
    Sensors (Basel); 2014 Feb; 14(2):3458-76. PubMed ID: 24561398
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Coupling mechanism of an EMAT.
    Jian X; Dixon S; Edwards RS; Morrison J
    Ultrasonics; 2006 Dec; 44 Suppl 1():e653-6. PubMed ID: 16793101
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Guided Wave Transducer with Sprayed Magnetostrictive Powder Coating for Monitoring of Aluminum Conductor Steel-Reinforced Cables.
    Lv F; Zhang P; Tang Z; Yue Y; Yang K
    Sensors (Basel); 2019 Mar; 19(7):. PubMed ID: 30935068
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Relative Ability of Wedge-Coupled Piezoelectric and Meander Coil EMAT Probes to Generate Single-Mode Lamb Waves.
    Khalili P; Cawley P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Apr; 65(4):648-656. PubMed ID: 29610094
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The excitation and detection of lamb waves with planar coil electromagnetic acoustic transducers.
    Wilcox PD; Lowe MJ; Cawley P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2370-83. PubMed ID: 16463504
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Design and experiment of array Rayleigh wave-EMAT for plane stress measurement.
    Liu H; Liu T; Yang P; Liu Y; Gao S; Li Y; Li T; Wang Y
    Ultrasonics; 2022 Mar; 120():106639. PubMed ID: 34953343
    [TBL] [Abstract][Full Text] [Related]  

  • 39. EMAT design for minimum remnant thickness gauging using high order shear horizontal modes.
    Thon A; Bélanger P
    Ultrasonics; 2019 May; 95():70-78. PubMed ID: 30897386
    [TBL] [Abstract][Full Text] [Related]  

  • 40. High Temperature Shear Horizontal Electromagnetic Acoustic Transducer for Guided Wave Inspection.
    Kogia M; Gan TH; Balachandran W; Livadas M; Kappatos V; Szabo I; Mohimi A; Round A
    Sensors (Basel); 2016 Apr; 16(4):. PubMed ID: 27110792
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.