These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
259 related articles for article (PubMed ID: 38109928)
1. 'Single-shot' pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy. Pu S; Liu F; Chen Y; Luo C; Li P; Chen Y; Fu L; Liu H; Ye X; Wu S; Xue Y; Lin W Europace; 2023 Dec; 26(1):. PubMed ID: 38109928 [TBL] [Abstract][Full Text] [Related]
2. Pulsed field ablation for pulmonary vein isolation: Preclinical safety and effectiveness of a novel hexaspline ablation catheter. Yu F; Dong X; Ding L; Reddy V; Tang M J Cardiovasc Electrophysiol; 2023 Nov; 34(11):2195-2202. PubMed ID: 37712346 [TBL] [Abstract][Full Text] [Related]
3. First-in-human clinical series of a novel conformable large-lattice pulsed field ablation catheter for pulmonary vein isolation. Reddy VY; Anter E; Peichl P; Rackauskas G; Petru J; Funasako M; Koruth JS; Marinskis G; Turagam M; Aidietis A; Kautzner J; Natale A; Neuzil P Europace; 2024 Mar; 26(4):. PubMed ID: 38584468 [TBL] [Abstract][Full Text] [Related]
5. Characterization of circumferential antral pulmonary vein isolation areas resulting from pulsed-field catheter ablation. Bohnen M; Weber R; Minners J; Jadidi A; Eichenlaub M; Neumann FJ; Arentz T; Lehrmann H Europace; 2023 Feb; 25(1):65-73. PubMed ID: 35852306 [TBL] [Abstract][Full Text] [Related]
6. Pulsed Field Ablation of Paroxysmal Atrial Fibrillation: 1-Year Outcomes of IMPULSE, PEFCAT, and PEFCAT II. Reddy VY; Dukkipati SR; Neuzil P; Anic A; Petru J; Funasako M; Cochet H; Minami K; Breskovic T; Sikiric I; Sediva L; Chovanec M; Koruth J; Jais P JACC Clin Electrophysiol; 2021 May; 7(5):614-627. PubMed ID: 33933412 [TBL] [Abstract][Full Text] [Related]
7. Preclinical assessment of the feasibility, safety and lesion durability of a novel 'single-shot' pulsed field ablation catheter for pulmonary vein isolation. Koruth J; Kawamura I; Dukkipati SR; Neuzil P; Reddy VY Europace; 2023 Apr; 25(4):1369-1378. PubMed ID: 36794699 [TBL] [Abstract][Full Text] [Related]
8. Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation. Reddy VY; Neuzil P; Koruth JS; Petru J; Funosako M; Cochet H; Sediva L; Chovanec M; Dukkipati SR; Jais P J Am Coll Cardiol; 2019 Jul; 74(3):315-326. PubMed ID: 31085321 [TBL] [Abstract][Full Text] [Related]
9. Application of a circular-shaped pulsed field ablation catheter with magnetic sensors for pulmonary vein isolation: a multi-centre clinical study report. Wang Y; Lai HL; Chen Q; Liu H; Liu QM; Huang WB; Tao Y; Xiong Q; Zhou N; Zhao C; Qiu J; Xu Z; Wang DW Europace; 2024 Mar; 26(4):. PubMed ID: 38584395 [TBL] [Abstract][Full Text] [Related]
10. Pulsed-field ablation-based pulmonary vein isolation: acute safety, efficacy and short-term follow-up in a multi-center real world scenario. Lemoine MD; Fink T; Mencke C; Schleberger R; My I; Obergassel J; Bergau L; Sciacca V; Rottner L; Moser J; Kany S; Moser F; Münkler P; Dinshaw L; Kirchhof P; Reissmann B; Ouyang F; Sommer P; Sohns C; Rillig A; Metzner A Clin Res Cardiol; 2023 Jun; 112(6):795-806. PubMed ID: 36131138 [TBL] [Abstract][Full Text] [Related]
11. Lattice-tip catheter for single-shot pulmonary vein isolation with pulsed field ablation. Yavin HD; Higuchi K; Younis A; Anter E J Interv Card Electrophysiol; 2023 Oct; 66(7):1741-1748. PubMed ID: 36441424 [TBL] [Abstract][Full Text] [Related]
12. Acute lesion extension following pulmonary vein isolation with two novel single shot devices: Pulsed field ablation versus multielectrode radiofrequency balloon. My I; Lemoine MD; Butt M; Mencke C; Loeck FW; Obergassel J; Rottner L; Wenzel JP; Schleberger R; Moser J; Moser F; Kirchhof P; Reissmann B; Ouyang F; Rillig A; Metzner A J Cardiovasc Electrophysiol; 2023 Sep; 34(9):1802-1807. PubMed ID: 37473404 [TBL] [Abstract][Full Text] [Related]
13. Pulsed Field Ablation in Patients With Persistent Atrial Fibrillation. Reddy VY; Anic A; Koruth J; Petru J; Funasako M; Minami K; Breskovic T; Sikiric I; Dukkipati SR; Kawamura I; Neuzil P J Am Coll Cardiol; 2020 Sep; 76(9):1068-1080. PubMed ID: 32854842 [TBL] [Abstract][Full Text] [Related]
14. How does the level of pulmonary venous isolation compare between pulsed field ablation and thermal energy ablation (radiofrequency, cryo, or laser)? Kawamura I; Neuzil P; Shivamurthy P; Kuroki K; Lam J; Musikantow D; Chu E; Turagam MK; Minami K; Funasako M; Petru J; Choudry S; Miller MA; Langan MN; Whang W; Dukkipati SR; Koruth JS; Reddy VY Europace; 2021 Nov; 23(11):1757-1766. PubMed ID: 34151947 [TBL] [Abstract][Full Text] [Related]
15. Efficacy and safety of a novel hexaspline pulsed field ablation system in patients with paroxysmal atrial fibrillation: the PLEASE-AF study. Wang Z; Tang M; Reddy VY; Chu H; Liu X; Xue Y; Wang J; Xu J; Liu S; Xu W; Zhang Z; Han B; Hong L; Yang B; Ding M; Liang M Europace; 2024 Jul; 26(7):. PubMed ID: 38912887 [TBL] [Abstract][Full Text] [Related]
16. In vivo porcine characterization of atrial lesion safety and efficacy utilizing a circular pulsed-field ablation catheter including assessment of collateral damage to adjacent tissue in supratherapeutic ablation applications. Hsu JC; Gibson D; Banker R; Doshi SK; Gidney B; Gomez T; Berman D; Datta K; Govari A; Natale A J Cardiovasc Electrophysiol; 2022 Jul; 33(7):1480-1488. PubMed ID: 35510408 [TBL] [Abstract][Full Text] [Related]
17. Long-term outcomes of the pentaspline pulsed-field ablation catheter for the treatment of paroxysmal atrial fibrillation: results of the prospective, multicentre FARA-Freedom Study. Metzner A; Fiala M; Vijgen J; Ouss A; Gunawardene M; Hansen J; Kautzner J; Schmidt B; Duytschaever M; Reichlin T; Blaauw Y; Sommer P; Vanderper A; Achyutha AB; Johnson M; Raybuck JD; Neuzil P Europace; 2024 Mar; 26(3):. PubMed ID: 38385529 [TBL] [Abstract][Full Text] [Related]
18. Pulsed-field ablation combined with ultrahigh-density mapping in patients undergoing catheter ablation for atrial fibrillation: Practical and electrophysiological considerations. Gunawardene MA; Schaeffer BN; Jularic M; Eickholt C; Maurer T; Akbulak RÖ; Flindt M; Anwar O; Pape UF; Maasberg S; Gessler N; Hartmann J; Willems S J Cardiovasc Electrophysiol; 2022 Mar; 33(3):345-356. PubMed ID: 34978360 [TBL] [Abstract][Full Text] [Related]
19. First experience with pulsed field ablation as routine treatment for paroxysmal atrial fibrillation. Füting A; Reinsch N; Höwel D; Brokkaar L; Rahe G; Neven K Europace; 2022 Jul; 24(7):1084-1092. PubMed ID: 35513354 [TBL] [Abstract][Full Text] [Related]
20. Paroxysmal Atrial Fibrillation Ablation Using a Novel Variable-Loop Biphasic Pulsed Field Ablation Catheter Integrated With a 3-Dimensional Mapping System: 1-Year Outcomes of the Multicenter inspIRE Study. Duytschaever M; De Potter T; Grimaldi M; Anic A; Vijgen J; Neuzil P; Van Herendael H; Verma A; Skanes A; Scherr D; Pürerfellner H; Rackauskas G; Jaïs P; Reddy VY; Circ Arrhythm Electrophysiol; 2023 Mar; 16(3):e011780. PubMed ID: 36735937 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]