BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 38117132)

  • 1. CAROTID ARTERY ULTRASOUND FOR ASSESSING FLUID RESPONSIVENESS IN PATIENTS UNDERGOING MECHANICAL VENTILATION WITH LOW TIDAL VOLUME AND PRESERVED SPONTANEOUS BREATHING.
    Zhou K; Ran S; Guo Y; Ye H
    Shock; 2024 Mar; 61(3):360-366. PubMed ID: 38117132
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Predictive value of carotid ultrasound in combination with passive leg raising on fluid responsiveness in critically ill patients].
    Shao X; Chen Q; Tang W; Zhu L; Lu E
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2021 Sep; 33(9):1105-1109. PubMed ID: 34839870
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation.
    Myatra SN; Prabu NR; Divatia JV; Monnet X; Kulkarni AP; Teboul JL
    Crit Care Med; 2017 Mar; 45(3):415-421. PubMed ID: 27922879
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease.
    Song Y; Kwak YL; Song JW; Kim YJ; Shim JK
    Br J Anaesth; 2014 Jul; 113(1):61-6. PubMed ID: 24722322
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Cephalic artery peak velocity variation during passive leg raising can predict fluid responsiveness in mechanically ventilated severe sepsis patients with spontaneous breathing].
    Xue YM; Zeng LJ; Chen DW; Lai BC; Xu BF; He JY; Wu W; Lin FH
    Zhonghua Yi Xue Za Zhi; 2018 Aug; 98(31):2476-2480. PubMed ID: 30138998
    [No Abstract]   [Full Text] [Related]  

  • 6. Carotid doppler ultrasonography as a method to predict fluid responsiveness in mechanically ventilated children.
    de Souza TB; Rubio AJ; Carioca FL; Ferraz IS; Brandão MB; Nogueira RJN; de Souza TH
    Paediatr Anaesth; 2022 Sep; 32(9):1038-1046. PubMed ID: 35748620
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Passive leg raising test induced changes in plethysmographic variability index to assess fluid responsiveness in critically ill mechanically ventilated patients with acute circulatory failure.
    Mallat J; Lemyze M; Fischer MO
    J Crit Care; 2024 Feb; 79():154449. PubMed ID: 37857068
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasound Assessment of the Change in Carotid Corrected Flow Time in Fluid Responsiveness in Undifferentiated Shock.
    Barjaktarevic I; Toppen WE; Hu S; Aquije Montoya E; Ong S; Buhr R; David IJ; Wang T; Rezayat T; Chang SY; Elashoff D; Markovic D; Berlin D; Cannesson M
    Crit Care Med; 2018 Nov; 46(11):e1040-e1046. PubMed ID: 30134304
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Carotid doppler indices do not predict fluid responsiveness in mechanically ventilated patients undergoing coronary artery bypass grafting surgery.
    Khan S; Mishra SK; Parida S; Jha AK; Nagabhushanam Padala SRA
    J Card Surg; 2022 Dec; 37(12):4418-4424. PubMed ID: 36251251
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Carotid ultrasound measurements for assessing fluid responsiveness in spontaneously breathing patients: corrected flow time and respirophasic variation in blood flow peak velocity.
    Kim DH; Shin S; Kim N; Choi T; Choi SH; Choi YS
    Br J Anaesth; 2018 Sep; 121(3):541-549. PubMed ID: 30115251
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrected flow time and respirophasic variation in blood flow peak velocity of radial artery predict fluid responsiveness in gynecological surgical patients with mechanical ventilation.
    Shen J; Dai S; Tao X; Chen X; Xu L
    BMC Anesthesiol; 2022 Sep; 22(1):299. PubMed ID: 36123625
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Respiratory Variation in Carotid Artery Peak Systolic Velocity Is Unable to Predict Fluid Responsiveness in Spontaneously Breathing Critically Ill Patients When Assessed by Novice Physician Sonologists.
    Abbasi A; Nayeemuddin M; Azab N; Schick A; Lopardo T; Phillips GS; Merchant RC; Levy MM; Blaivas M; Corl KA
    J Intensive Care Med; 2021 Aug; 36(8):885-892. PubMed ID: 32597361
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predicting Fluid Responsiveness in Acute Liver Failure: A Prospective Study.
    Audimoolam VK; McPhail MJ; Willars C; Bernal W; Wendon JA; Cecconi M; Auzinger G
    Anesth Analg; 2017 Feb; 124(2):480-486. PubMed ID: 27984249
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Passive leg raising-induced changes in pulse pressure variation to assess fluid responsiveness in mechanically ventilated patients: a multicentre prospective observational study.
    Mallat J; Fischer MO; Granier M; Vinsonneau C; Jonard M; Mahjoub Y; Baghdadi FA; Préau S; Poher F; Rebet O; Bouhemad B; Lemyze M; Marzouk M; Besnier E; Hamed F; Rahman N; Abou-Arab O; Guinot PG
    Br J Anaesth; 2022 Sep; 129(3):308-316. PubMed ID: 35842352
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The association between carotid flow time and fluid responsiveness in children under general anesthesia.
    Lin EE; Glau C; Conlon TW; Chen AE; Kaplan SL; Posada A; Nishisaki A
    Paediatr Anaesth; 2022 Sep; 32(9):1047-1053. PubMed ID: 35735131
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Measurement of peak velocity variation of common carotid artery with bedside ultrasound to estimate preload in surgery ICU].
    Yin WH; Chen Y; Jin XD; Zuo YY; Kang Y; Wang B; Zeng XY
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2013 Jul; 44(4):624-8. PubMed ID: 24059122
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Variability of peripheral arterial peak velocity predicts fluid responsiveness in patients with septic shock].
    Lu N; Jiang L; Zhu B; Han W; Zhao Y; Shi Y; Guo F; Xi X
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2018 Mar; 30(3):224-229. PubMed ID: 29519280
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correlation of carotid corrected flow time and respirophasic variation in blood flow peak velocity with stroke volume variation in elderly patients under general anaesthesia.
    Chen Y; Liu Z; Fang J; Xie Y; Zhang M; Yang J
    BMC Anesthesiol; 2022 Aug; 22(1):246. PubMed ID: 35927621
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Accuracy of Velocity-Time Integral Variation and Peak Velocity Variation of the Left Ventricular Outflow Tract in Predicting Fluid Responsiveness in Postoperative Patients Mechanically Ventilated at Low Tidal Volumes.
    Xie J; Wan J; Xu L; Zhang Y; Chen J
    J Cardiothorac Vasc Anesth; 2023 Jun; 37(6):911-918. PubMed ID: 36931906
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes.
    Oliveira-Costa CD; Friedman G; Vieira SR; Fialkow L
    Clinics (Sao Paulo); 2012 Jul; 67(7):773-8. PubMed ID: 22892922
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.