These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 38130700)

  • 21. A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone.
    Quaresma SE; Cury PR; Sendyk WR; Sendyk C
    J Oral Implantol; 2008; 34(1):1-6. PubMed ID: 18390236
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Stress distribution around different abutments on titanium and CFR-PEEK implant with different prosthetic crowns under parafunctional loading: A 3D FEA study.
    Mourya A; Nahar R; Mishra SK; Chowdhary R
    J Oral Biol Craniofac Res; 2021; 11(2):313-320. PubMed ID: 33816100
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fracture strength of various titanium-based, CAD-CAM and PFM implant crowns.
    DuVall NB; DeReis SP; Vandewalle KS
    J Esthet Restor Dent; 2021 Apr; 33(3):522-530. PubMed ID: 33174333
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical evaluation of anterior implants associated with titanium and zirconia abutments and monotype zirconia implants.
    Brandão de Holanda KA; Armini Caldas R; Amaral M; da Silva Concilio LR; Pino Vitti R
    J Prosthodont Res; 2021 Feb; 65(1):73-77. PubMed ID: 32938877
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown.
    Sevimay M; Turhan F; Kiliçarslan MA; Eskitascioglu G
    J Prosthet Dent; 2005 Mar; 93(3):227-34. PubMed ID: 15775923
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface.
    Hjerppe J; Jung RE; Hämmerle CH; Özcan M; Mühlemann S
    J Dent; 2022 Jun; 121():104121. PubMed ID: 35395344
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The Effect of Abutment Angulation and Crown Material Compositions on Stress Distribution in 3-Unit Fixed Implant-Supported Prostheses: A Finite Element Analysis.
    Mosharraf R; Abbasi M; Givehchian P
    Int J Dent; 2022; 2022():4451810. PubMed ID: 36065400
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Failure Load of Monolithic Lithium Disilicate Implant-Supported Single Crowns Bonded to Ti-base Abutments versus to Customized Ceramic Abutments after Fatigue.
    Spitznagel FA; Bonfante EA; Vollmer F; Gierthmuehlen PC
    J Prosthodont; 2022 Feb; 31(2):136-146. PubMed ID: 33870577
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Fracture resistance of different implant supported ceramic abutment/crown systems.
    Bankoglu Gungor M; Karakoca Nemli S; Yilmaz H; Aydin C
    Eur Oral Res; 2019 May; 53(2):80-87. PubMed ID: 31309198
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical Evaluation of Different Implant-Abutment Connections, Retention Systems, and Restorative Materials in the Implant-Supported Single Crowns Using 3D Finite Element Analysis.
    Lemos CAA; Verri FR; Noritomi PY; de Souza Batista VE; Cruz RS; de Luna Gomes JM; de Oliveira Limírio JPJ; Pellizzer EP
    J Oral Implantol; 2022 Jun; 48(3):194-201. PubMed ID: 34091686
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Different combinations of CAD/CAM materials on the biomechanical behavior of a two-piece prosthetic solution.
    Tribst JPM; Dal Piva AMO; Borges ALS; Bottino MA
    Int J Comput Dent; 2019; 22(2):171-176. PubMed ID: 31134223
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results.
    Cooper LF; Stanford C; Feine J; McGuire M
    J Prosthet Dent; 2016 Jul; 116(1):33-9. PubMed ID: 26831919
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Fracture Resistance of Single-Unit Implant-Supported Crowns: Effects of Prosthetic Design and Restorative Material.
    Donmez MB; Diken Turksayar AA; Olcay EO; Sahmali SM
    J Prosthodont; 2022 Apr; 31(4):348-355. PubMed ID: 34383979
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Fracture resistance and the mode of failure produced in metal-free crowns cemented onto zirconia abutments in dental implants.
    Agustín-Panadero R; Serra-Pastor B; Roig-Vanaclocha A; Fons-Font A; Solá-Ruiz MF
    PLoS One; 2019; 14(8):e0220551. PubMed ID: 31393888
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of different occlusal materials on peri-implant stress distribution with different osseointegration condition: A finite element analysis.
    Thirumaran D; Leoney A; Fayeez A; Yazhini Shanmya P
    J Indian Prosthodont Soc; 2024 Jul; 24(3):292-299. PubMed ID: 38946514
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Stress distribution in the abutment and retention screw of a single implant supporting a prosthesis with platform switching.
    Alvarez-Arenal A; Segura-Mori L; Gonzalez-Gonzalez I; Gago A
    Int J Oral Maxillofac Implants; 2013; 28(3):e112-21. PubMed ID: 23748329
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Mechanical Fatigue Analysis of PEEK as Alternative to Zirconia for Definitive Hybrid Abutments Supporting All-Ceramic Crowns.
    Barbosa-Júnior SA; Pereira GKR; Dapieve KS; Machado PS; Valandro LF; Schuh C; Consani RLX; Bacchi A
    Int J Oral Maxillofac Implants; 2020; 35(6):1209-1217. PubMed ID: 33270062
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Stress dissipation in the bone through various crown materials of dental implant restoration: a 2-D finite element analysis.
    Bijjargi S; Chowdhary R
    J Investig Clin Dent; 2013 Aug; 4(3):172-7. PubMed ID: 23172842
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns.
    Elshiyab SH; Nawafleh N; Öchsner A; George R
    J Adv Prosthodont; 2018 Feb; 10(1):65-72. PubMed ID: 29503716
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Analysis of Stress Distribution on the Bone around an Implant Placed in the Anterior Maxilla Using Three Different Abutment Angulations by Means of Finite Element Analysis.
    Shende S; Jadhav A; Edake DN; Patil AH; Patil H; Agrawal N
    J Pharm Bioallied Sci; 2021 Nov; 13(Suppl 2):S1591-S1596. PubMed ID: 35018036
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.