These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 38130909)

  • 41. Mariner 9 michelson interferometer.
    Hanel R; Schlachman B; Breihan E; Bywaters R; Chapman F; Rhodes M; Rodgers D; Vanous D
    Appl Opt; 1972 Nov; 11(11):2625-34. PubMed ID: 20119381
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Multichannel Fourier-transform infrared spectrometer.
    Hashimoto M; Kawata S
    Appl Opt; 1992 Oct; 31(28):6096-101. PubMed ID: 20733812
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore electron beam ion traps.
    Hell N; Beiersdorfer P; Magee EW; Brown GV
    Rev Sci Instrum; 2016 Nov; 87(11):11D604. PubMed ID: 27910351
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response.
    Troussel P; Villette B; Emprin B; Oudot G; Tassin V; Bridou F; Delmotte F; Krumrey M
    Rev Sci Instrum; 2014 Jan; 85(1):013503. PubMed ID: 24517761
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests.
    Wiens RC; Maurice S; Robinson SH; Nelson AE; Cais P; Bernardi P; Newell RT; Clegg S; Sharma SK; Storms S; Deming J; Beckman D; Ollila AM; Gasnault O; Anderson RB; André Y; Michael Angel S; Arana G; Auden E; Beck P; Becker J; Benzerara K; Bernard S; Beyssac O; Borges L; Bousquet B; Boyd K; Caffrey M; Carlson J; Castro K; Celis J; Chide B; Clark K; Cloutis E; Cordoba EC; Cousin A; Dale M; Deflores L; Delapp D; Deleuze M; Dirmyer M; Donny C; Dromart G; George Duran M; Egan M; Ervin J; Fabre C; Fau A; Fischer W; Forni O; Fouchet T; Fresquez R; Frydenvang J; Gasway D; Gontijo I; Grotzinger J; Jacob X; Jacquinod S; Johnson JR; Klisiewicz RA; Lake J; Lanza N; Laserna J; Lasue J; Le Mouélic S; Legett C; Leveille R; Lewin E; Lopez-Reyes G; Lorenz R; Lorigny E; Love SP; Lucero B; Madariaga JM; Madsen M; Madsen S; Mangold N; Manrique JA; Martinez JP; Martinez-Frias J; McCabe KP; McConnochie TH; McGlown JM; McLennan SM; Melikechi N; Meslin PY; Michel JM; Mimoun D; Misra A; Montagnac G; Montmessin F; Mousset V; Murdoch N; Newsom H; Ott LA; Ousnamer ZR; Pares L; Parot Y; Pawluczyk R; Glen Peterson C; Pilleri P; Pinet P; Pont G; Poulet F; Provost C; Quertier B; Quinn H; Rapin W; Reess JM; Regan AH; Reyes-Newell AL; Romano PJ; Royer C; Rull F; Sandoval B; Sarrao JH; Sautter V; Schoppers MJ; Schröder S; Seitz D; Shepherd T; Sobron P; Dubois B; Sridhar V; Toplis MJ; Torre-Fdez I; Trettel IA; Underwood M; Valdez A; Valdez J; Venhaus D; Willis P
    Space Sci Rev; 2021; 217(1):4. PubMed ID: 33380752
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes.
    Ottaway JM; Allen A; Waldron A; Paul PH; Angel SM; Carter JC
    Appl Spectrosc; 2019 Oct; 73(10):1160-1171. PubMed ID: 31397584
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Spectral Measurements of Muzzle Flash with a Temporally and Spatially Modulated LWIR-Imaging Fourier Transform Spectrometer.
    Yang Z; Li K; Yu C; Yuan M; Wang B; Feng J
    Sensors (Basel); 2023 Apr; 23(8):. PubMed ID: 37112204
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Calibration algorithm for Fourier transform spectrometer with thermal instabilities.
    Turbide S; Smithson T
    Appl Opt; 2010 Jun; 49(17):3411-7. PubMed ID: 20539361
    [TBL] [Abstract][Full Text] [Related]  

  • 49. MWIR thermal imaging spectrometer based on the acousto-optic tunable filter.
    Zhao H; Ji Z; Jia G; Zhang Y; Li Y; Wang D
    Appl Opt; 2017 Sep; 56(25):7269-7276. PubMed ID: 29047991
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Measurement of internal stray radiation of a thermal infrared spectrometer based on temperature variation.
    Peng J; Yue X; Du HT; Yin ZH; Chai MY; Sun DX; Liu YN
    Appl Opt; 2019 Nov; 58(31):8457-8464. PubMed ID: 31873329
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Synchronized high speed scanning infrared spectrometer.
    Camm JC; Taylor RL; Lynch R
    Appl Opt; 1967 May; 6(5):885-91. PubMed ID: 20057870
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature.
    Schmuck S; Fessey J; Gerbaud T; Alper B; Beurskens MN; de la Luna E; Sirinelli A; Zerbini M;
    Rev Sci Instrum; 2012 Dec; 83(12):125101. PubMed ID: 23282107
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Simulation and calibration of a compact millimeter-wavelength Fourier transform spectrometer.
    Liu M; Pan Z; Basu Thakur R; Meyer SS
    Appl Opt; 2020 Sep; 59(25):7726-7733. PubMed ID: 32902475
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Calibration and performances of the MicrOmega instrument for the characterization of asteroid Ryugu returned samples.
    Riu L; Pilorget C; Hamm V; Bibring JP; Lantz C; Loizeau D; Brunetto R; Carter J; Lequertier G; Lourit L; Okada T; Yogata K; Hatakeda K; Nakato A; Yada T
    Rev Sci Instrum; 2022 May; 93(5):054503. PubMed ID: 35649797
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Portable cavity ring-down spectrometer for an HO
    Wang C; Zhao W; Fang B; Yang N; Cheng F; Hu X; Chen Y; Zhang W; Fittschen C; Chen W
    Opt Express; 2022 Oct; 30(21):37446-37456. PubMed ID: 36258333
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Enhanced Static Modulated Fourier Transform Spectrometer for Fast Approximation in Field Application.
    Cho JY; Oh WC; Jang WK
    Molecules; 2021 May; 26(11):. PubMed ID: 34072968
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Fourier fluorescence spectrometer for excitation emission matrix measurement.
    Peng L; Gardecki JA; Bouma BE; Tearney GJ
    Opt Express; 2008 Jul; 16(14):10493-500. PubMed ID: 18607462
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Ground and In-Flight Calibration of the OSIRIS-REx Camera Suite.
    Golish DR; Drouet d'Aubigny C; Rizk B; DellaGiustina DN; Smith PH; Becker K; Shultz N; Stone T; Barker MK; Mazarico E; Tatsumi E; Gaskell RW; Harrison L; Merrill C; Fellows C; Williams B; O'Dougherty S; Whiteley M; Hancock J; Clark BE; Hergenrother CW; Lauretta DS
    Space Sci Rev; 2020; 216(1):12. PubMed ID: 32025061
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Solid-state digital micro-mirror array spectrometer for Hadamard transform measurements of glucose and lactate in aqueous solutions.
    Xiang D; Arnold MA
    Appl Spectrosc; 2011 Oct; 65(10):1170-80. PubMed ID: 21986077
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Balloon-borne stratospheric far-IR spectral absorption measurements: the design of a solar telescope and high-resolution Michelson interferometer combination.
    Naylor DA; Clark TA; Boreiko RT
    Appl Opt; 1981 Apr; 20(7):1132-44. PubMed ID: 20309276
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.