BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 3814191)

  • 1. Clinical uses of enzyme electrode probes.
    Mascini M; Guilbault GG
    Biosensors; 1986; 2(3):147-72. PubMed ID: 3814191
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Suitable potentiometric enzyme sensors for urea and creatinine.
    Campanella L; Sammartino MP; Tomassetti M
    Analyst; 1990 Jun; 115(6):827-30. PubMed ID: 2393088
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A highly selective amperometric biosensor array for the simultaneous determination of glutamate, glucose, choline, acetylcholine, lactate and pyruvate.
    Kucherenko DY; Kucherenko IS; Soldatkin OO; Topolnikova YV; Dzyadevych SV; Soldatkin AP
    Bioelectrochemistry; 2019 Aug; 128():100-108. PubMed ID: 30959397
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Amperometric ammonium ion and urea determination with enzyme-based probes.
    Bertocchi P; Compagnone D; Palleschi G
    Biosens Bioelectron; 1996; 11(1-2):1-10. PubMed ID: 8600914
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer.
    Garguilo MG; Huynh N; Proctor A; Michael AC
    Anal Chem; 1993 Mar; 65(5):523-8. PubMed ID: 8452244
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Potentiometric measurement of glucose concentration with an immobilized glucose oxidase/catalase electrode.
    Wingard LB; Liu CC; Wolfson SK; Yao SJ; Drash AL
    Diabetes Care; 1982; 5(3):199-202. PubMed ID: 7172983
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of acetylcholine sensor using carbon fiber (amperometric determination).
    Navera EN; Sode K; Tamiya E; Karube I
    Biosens Bioelectron; 1991; 6(8):675-80. PubMed ID: 1793553
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Immobilized enzyme electrodes for the potentiometric measurement of glucose concentration: immobilization techniques and materials.
    Wingard LB; Schiller JG; Wolfson SK; Liu CC; Drash AL; Yao SJ
    J Biomed Mater Res; 1979 Nov; 13(6):921-35. PubMed ID: 117008
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enhanced measurement stability and selectivity for choline and acetylcholine by capillary electrophoresis with electrochemical detection at a covalently linked enzyme-modified electrode.
    Inoue T; Kirchhoff JR; Hudson RA
    Anal Chem; 2002 Oct; 74(20):5321-6. PubMed ID: 12403587
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Disposable, enzymatically modified printed film carbon electrodes for use in the high-performance liquid chromatographic-electrochemical detection of glucose or hydrogen peroxide from immobilized enzyme reactors.
    Osborne PG; Yamamoto K
    J Chromatogr B Biomed Sci Appl; 1998 Apr; 707(1-2):3-8. PubMed ID: 9613927
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coupling of enzyme reactions to the charge transfer at the interface of two immiscible solvents.
    Senda M
    EXS; 1997; 80():193-207. PubMed ID: 9002214
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Potentiometric Urea Biosensor Based on Carbon Nanotubes and Polyion Complex Film.
    Nguyen LT; Yoon HH
    J Nanosci Nanotechnol; 2015 Feb; 15(2):1150-3. PubMed ID: 26353625
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Development and applications of enzyme electrode sensors].
    Osawa H
    Tanpakushitsu Kakusan Koso; 1985 Apr; 30(4):264-76. PubMed ID: 3892586
    [No Abstract]   [Full Text] [Related]  

  • 14. Glucose oxidase immobilized electrode for potentiometric estimation of glucose.
    Alva S; Sen Gupta S; Phadke RS; Govil G
    Biosens Bioelectron; 1991; 6(8):663-8. PubMed ID: 1793552
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Application of electrochemical biosensors in clinical diagnosis.
    Monošík R; Stred'anský M; Šturdík E
    J Clin Lab Anal; 2012 Jan; 26(1):22-34. PubMed ID: 24833531
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Acetylcholine and choline amperometric enzyme sensors characterized in vitro and in vivo.
    Mitchell KM
    Anal Chem; 2004 Feb; 76(4):1098-106. PubMed ID: 14961744
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Amperometric determination of acetylcholine-A neurotransmitter, by chitosan/gold-coated ferric oxide nanoparticles modified gold electrode.
    Chauhan N; Pundir CS
    Biosens Bioelectron; 2014 Nov; 61():1-8. PubMed ID: 24836212
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Polyvinylferrocenium modified Pt electrode for the design of amperometric choline and acetylcholine enzyme electrodes.
    Sen S; Gülce A; Gülce H
    Biosens Bioelectron; 2004 May; 19(10):1261-8. PubMed ID: 15046758
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Amperometric alcohol electrode with extended linearity and reduced interferences.
    Lubrano GJ; Faridnia MH; Palleschi G; Gyilbault GG
    Anal Biochem; 1991 Oct; 198(1):97-103. PubMed ID: 1789436
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Amperometric and potentiometric enzyme electrodes.
    Ho MH
    Biomed Sci Instrum; 1984; 20():85-91. PubMed ID: 6713059
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.