BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 38142945)

  • 1. Comparison of bare and nonbare stent grafts during thoracic endovascular aneurysm repair of the aortic arch.
    Leone N; Bartolotti LAM; Capitain AN; Migliari M; Silingardi R; Czerny M; Rylski B; Gennai S
    J Vasc Surg; 2024 May; 79(5):997-1004.e1. PubMed ID: 38142945
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determining the Optimal Proximal Landing Zone for TEVAR in the Aortic Arch: Comparing the Occurrence of the Bird-Beak Phenomenon in Zone 0 vs Zones 1 and 2.
    Kudo T; Kuratani T; Shimamura K; Sawa Y
    J Endovasc Ther; 2020 Jun; 27(3):368-376. PubMed ID: 32242769
    [No Abstract]   [Full Text] [Related]  

  • 3. Fenestrated Thoracic Endovascular Aortic Repair Using Physician Modified Stent Grafts for Acute Type B Aortic Dissection with Unfavourable Landing Zone.
    Zhu J; Zhao L; Dai X; Luo Y; Fan H; Feng Z; Zhang Y; Hu F
    Eur J Vasc Endovasc Surg; 2018 Feb; 55(2):170-176. PubMed ID: 29241685
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-term results of total endovascular repair of arch-involving aortic pathologies using parallel grafts for supra-aortic debranching.
    Dueppers P; Reutersberg B; Rancic Z; Messmer F; Menges AL; Meuli L; Rychla M; Zimmermann A
    J Vasc Surg; 2022 Mar; 75(3):813-823.e1. PubMed ID: 34606961
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of Risk Factors for Early Type I Endoleaks After Thoracic Endovascular Aneurysm Repair.
    Kanaoka Y; Ohki T; Maeda K; Baba T
    J Endovasc Ther; 2017 Feb; 24(1):89-96. PubMed ID: 27760812
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Total Arch Thoracic Endovascular Aortic Repair Using Double Fenestrated Physician-Modified Stent-Grafts: 100 Patients.
    Canaud L; Chassin-Trubert L; Abouliatim I; Hireche K; Bacri C; Alric P; Gandet T
    J Endovasc Ther; 2024 Feb; 31(1):89-97. PubMed ID: 35927926
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of Thoracic Endovascular Aortic Repair Using Relay Proximal Scallop: Results of a French Prospective Multicentre Study.
    Derycke L; Tomasi J; Desgranges P; Pesteil F; Plissonier D; Pernot M; Millon A; Martinez R; Chakfe N; Alsac JM
    Eur J Vasc Endovasc Surg; 2023 Dec; 66(6):821-829. PubMed ID: 37567339
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Four-year results of the Bolton relay proximal scallop endograft in the management of thoracic and thoracoabdominal aortic pathology with unfavorable proximal landing zone.
    Hanna L; Abdullah A; Kashef E; Riga C; Jenkins M; Bicknell C; Gibbs R; Hamady M
    J Vasc Surg; 2021 Nov; 74(5):1447-1455. PubMed ID: 33940076
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Morphologic performance analysis of the Relay nonbare stent graft in dissected thoracic aorta.
    Lescan M; Czerny M; Berezowski M; Andic M; Bamberg F; Beyersdorf F; Schlensak C; Rylski B
    J Vasc Surg; 2019 Nov; 70(5):1390-1398. PubMed ID: 31126770
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Outcomes of thoracic endovascular aortic repair using aortic arch chimney stents in high-risk patients.
    Voskresensky I; Scali ST; Feezor RJ; Fatima J; Giles KA; Tricarico R; Berceli SA; Beck AW
    J Vasc Surg; 2017 Jul; 66(1):9-20.e3. PubMed ID: 28216358
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the Outcomes of Total Endovascular Aortic Arch Repair Between Branched Endograft and Chimney Endograft Technique in Zone 0 Landing.
    Kudo T; Kuratani T; Shirakawa Y; Shimamura K; Kin K; Sakamoto T; Shijo T; Watanabe Y; Masada K; Sakaniwa R; Sawa Y
    J Endovasc Ther; 2022 Jun; 29(3):427-437. PubMed ID: 34802327
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Single-center experience with an inner branched arch endograft.
    Tsilimparis N; Detter C; Law Y; Rohlffs F; Heidemann F; Brickwedel J; von Kodolitsch Y; Debus ES; Kölbel T
    J Vasc Surg; 2019 Apr; 69(4):977-985.e1. PubMed ID: 30477941
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Outcomes of Zone 1 Thoracic Endovascular Aortic Repair With Fenestrated Surgeon-Modified Stent-Graft for Aortic Arch Pathologies.
    Li X; Zhang L; Song C; Zhang H; Xia S; Zhu L; Guo W; Li H; Jing Z; Lu Q
    J Endovasc Ther; 2024 Feb; 31(1):62-68. PubMed ID: 35786082
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of deployment of the Relay non-bare stent graft in the aortic arch.
    Riesterer T; Beyersdorf F; Scheumann J; Berezowski M; Schröfel H; Kondov S; Czerny M; Rylski B
    Interact Cardiovasc Thorac Surg; 2019 May; 28(5):797-802. PubMed ID: 30590614
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Outcome comparison of thoracic endovascular aortic repair performed outside versus inside proximal landing zone length recommendation.
    Yoon WJ; Mell MW
    J Vasc Surg; 2020 Dec; 72(6):1883-1890. PubMed ID: 32289436
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Initial results of thoracic endovascular repair for uncomplicated type B aortic dissection involving the arch vessels using a semicustom-made thoracic fenestrated stent graft.
    Fukushima S; Ohki T; Toya N; Shukuzawa K; Ito E; Murakami Y; Akiba T
    J Vasc Surg; 2019 Jun; 69(6):1694-1703. PubMed ID: 30786986
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reintervention after thoracic endovascular aortic repair of complicated aortic dissection.
    Faure EM; Canaud L; Agostini C; Shaub R; Böge G; Marty-ané C; Alric P
    J Vasc Surg; 2014 Feb; 59(2):327-33. PubMed ID: 24135620
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The repair of a type Ia endoleak following thoracic endovascular aortic repair using a stented elephant trunk procedure.
    Qi RD; Zhu JM; Liu YM; Chen L; Li CN; Xing XY; Sun LZ
    J Thorac Cardiovasc Surg; 2018 Apr; 155(4):1391-1396. PubMed ID: 29338866
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Endoleak outcomes with different stent-graft generations in a 25-years thoracic endovascular aortic repair experience.
    Gennai S; Leone N; Maria Bartolotti LA; Covic T; Lauricella A; Andreoli F; Saitta G; Silingardi R
    Vascular; 2022 Dec; 30(6):1069-1079. PubMed ID: 34971330
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thoracic Endovascular Aortic Repair With Single/Double Chimney Technique for Aortic Arch Pathologies.
    Wang T; Shu C; Li M; Li QM; Li X; Qiu J; Fang K; Dardik A; Yang CZ
    J Endovasc Ther; 2017 Jun; 24(3):383-393. PubMed ID: 28387611
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.