116 related articles for article (PubMed ID: 38148438)
1. A novel pneumatic drill for bone biopsy under MRI imaging.
Fischer E; Gebremeskel M; Stoianovici D; Sharma K; Cleary K
Int J Comput Assist Radiol Surg; 2024 Mar; 19(3):405-409. PubMed ID: 38148438
[TBL] [Abstract][Full Text] [Related]
2. Robotically assisted long bone biopsy under MRI: cadaver study results.
Lim S; Sharma K; Li P; Petrisor D; Fricke S; Stoianovici D; Cleary K
Int J Comput Assist Radiol Surg; 2019 Jan; 14(1):147-156. PubMed ID: 30456451
[TBL] [Abstract][Full Text] [Related]
3. Reduction of Radiation Dose and Scanning Time While Preserving Diagnostic Yield: A Comparison of Battery-Powered and Manual Bone Biopsy Systems.
Kihira S; Koo C; Lee A; Aggarwal A; Pawha P; Doshi A
AJNR Am J Neuroradiol; 2020 Mar; 41(3):387-392. PubMed ID: 32029464
[TBL] [Abstract][Full Text] [Related]
4. Comparison of powered drill & manual bone biopsy systems: Does the diagnostic yield justify the cost?
Huh EH; Yi PH; Ray DM; Hsu LCH; Hui FK; Khan M
J Clin Neurosci; 2020 Mar; 73():125-129. PubMed ID: 31992515
[TBL] [Abstract][Full Text] [Related]
5. [A new MR-(and CT-) compatible bone biopsy system: first clinical results].
Neuerburg J; Adam G; Bücker A; Zilkens KW; Schmitz-Rode T; Katterbach FJ; Klosterhalfen B; Rasmussen E; van Vaals JJ; Günther RW
Rofo; 1998 Nov; 169(5):515-20. PubMed ID: 9849603
[TBL] [Abstract][Full Text] [Related]
6. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.
Cohen MG; McMahon CJ; Kung JW; Wu JS
AJR Am J Roentgenol; 2016 May; 206(5):W83-6. PubMed ID: 26959290
[TBL] [Abstract][Full Text] [Related]
7. CT-guided bone biopsy with a battery-powered drill system: preliminary results.
Lee RK; Ng AW; Griffith JF
AJR Am J Roentgenol; 2013 Nov; 201(5):1093-5. PubMed ID: 24147481
[TBL] [Abstract][Full Text] [Related]
8. CT-guided radiofrequency ablation of osteoid osteoma using a novel battery-powered drill.
Schnapauff D; Streitparth F; Jöhrens K; Wieners G; Collettini F; Hamm B; Gebauer B
Skeletal Radiol; 2015 May; 44(5):695-701. PubMed ID: 25371086
[TBL] [Abstract][Full Text] [Related]
9. Differences in Radiation Exposure of CT-Guided Percutaneous Manual and Powered Drill Bone Biopsy.
Zensen S; Selvaretnam S; Opitz M; Bos D; Haubold J; Theysohn J; Forsting M; Guberina N; Wetter A
Cardiovasc Intervent Radiol; 2021 Sep; 44(9):1430-1438. PubMed ID: 33977330
[TBL] [Abstract][Full Text] [Related]
10. The effectiveness of a standard drill connected to a core biopsy needle: How to obtain specimens in very strong bone tumors.
Baldi J; Attala D; Scotto di Uccio A; Laquintana V; Biagini R; Zoccali C
Injury; 2018 Aug; 49(8):1612-1616. PubMed ID: 29903579
[TBL] [Abstract][Full Text] [Related]
11. CT-guided bone biopsy performed by means of a coaxial biopsy system with an eccentric drill.
Ahlström KH; Aström KG
Radiology; 1993 Aug; 188(2):549-52. PubMed ID: 8327713
[TBL] [Abstract][Full Text] [Related]
12. Percutaneous Biopsy and Radiofrequency Ablation of Osteoid Osteoma with Excess Reactive New Bone Formation and Cortical Thickening Using a Battery-Powered Drill for Access: A Technical Note.
Filippiadis D; Gkizas C; Kostantos C; Mazioti A; Reppas L; Brountzos E; Kelekis N; Kelekis A
Cardiovasc Intervent Radiol; 2016 Oct; 39(10):1499-505. PubMed ID: 27230513
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of potential tissue heating during percutaneous drill-assisted bone sampling in an in vivo porcine study.
Niehues SM; Elezkurtaj S; Bresssem KK; Hamm B; Erxleben C; Vahldiek J; Adams LC
Skeletal Radiol; 2022 Apr; 51(4):829-836. PubMed ID: 34462782
[TBL] [Abstract][Full Text] [Related]
14. CT-guided percutaneous biopsy of sclerotic bone lesions: diagnostic outcomes.
Chang IJ; Ilaslan H; Sundaram M; Schils J; Subhas N
Skeletal Radiol; 2018 May; 47(5):661-669. PubMed ID: 29218391
[TBL] [Abstract][Full Text] [Related]
15. Magnetic resonance imaging guided biopsy of musculoskeletal lesions.
Wu HT; Chang CY; Chang H; Yen CC; Cheng H; Chen PC; Chiou HJ
J Chin Med Assoc; 2012 Apr; 75(4):160-6. PubMed ID: 22541144
[TBL] [Abstract][Full Text] [Related]
16. Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series.
Wallace AN; Pacheco RA; Tomasian A; Hsi AC; Long J; Chang RO; Jennings JW
Cardiovasc Intervent Radiol; 2016 Feb; 39(2):290-5. PubMed ID: 26510661
[TBL] [Abstract][Full Text] [Related]
17. CT-Guided Percutaneous Spine Biopsy Specimen Adequacy, Pathology Concordance, and Negative Predictive Value with Battery-Powered Drill and Manual Approaches.
Guenette JP; Cho CH; Huang RY; Miskin N; Ghazikhanian V; Lee TC
Curr Probl Diagn Radiol; 2019; 48(6):558-562. PubMed ID: 30268583
[TBL] [Abstract][Full Text] [Related]
18. MRI-guided biopsy of bone in a hybrid system.
Neuerburg JM; Adam G; Buecker A; Zilkens KW; Schmitz-Rode T; Hunter D; van Vaals JJ; Guenther RW
J Magn Reson Imaging; 1998; 8(1):85-90. PubMed ID: 9500265
[TBL] [Abstract][Full Text] [Related]
19. Magnetic resonance-guided transcortical biopsy of bone marrow lesions using a magnetic resonance imaging-compatible piezoelectric power drill: preliminary experience.
König CW; Trübenbach J; Böhm P; Fritz J; Duda SH; Pereira PL
Invest Radiol; 2003 Mar; 38(3):159-63. PubMed ID: 12595796
[TBL] [Abstract][Full Text] [Related]
20. Comparison of cortical bone drilling induced heat production among common drilling tools.
Palmisano AC; Tai BL; Belmont B; Irwin TA; Shih A; Holmes JR
J Orthop Trauma; 2015 May; 29(5):e188-93. PubMed ID: 25233167
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]