These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 38153408)
1. Mixed Potential Type Acetone Sensor with Ultralow Detection Limit for Diabetic Ketosis Breath Analysis. Jiang L; Wang C; Fan T; Lv S; Pan S; Sun P; Zheng J; Zhang C; Liu F; Lu G ACS Sens; 2024 Jan; 9(1):464-473. PubMed ID: 38153408 [TBL] [Abstract][Full Text] [Related]
2. Efficient mixed-potential acetone sensor with yttria-stabilized zirconia and porous Co Hao X; Yu T; Meng X; Wei C; Wang Y; Sun S; Cheng P; Ji L J Hazard Mater; 2024 Oct; 478():135462. PubMed ID: 39126854 [TBL] [Abstract][Full Text] [Related]
3. Nanowire Array Breath Acetone Sensor for Diabetes Monitoring. Wei S; Li Z; Murugappan K; Li Z; Lysevych M; Vora K; Tan HH; Jagadish C; Karawdeniya BI; Nolan CJ; Tricoli A; Fu L Adv Sci (Weinh); 2024 May; 11(19):e2309481. PubMed ID: 38477429 [TBL] [Abstract][Full Text] [Related]
4. Breath ketone testing: a new biomarker for diagnosis and therapeutic monitoring of diabetic ketosis. Qiao Y; Gao Z; Liu Y; Cheng Y; Yu M; Zhao L; Duan Y; Liu Y Biomed Res Int; 2014; 2014():869186. PubMed ID: 24900994 [TBL] [Abstract][Full Text] [Related]
5. Correlation between blood ketones and exhaled acetone measured with a semiconducting gas sensor. Tsunemi S; Nakamura Y; Yokota K; Nakagawa T; Tsukiyama H; Kubo Y; Oyanagi T; Takemoto A; Nagai Y; Tanaka Y; Sone M J Breath Res; 2022 Aug; 16(4):. PubMed ID: 35868249 [TBL] [Abstract][Full Text] [Related]
6. Si:WO(3) Sensors for highly selective detection of acetone for easy diagnosis of diabetes by breath analysis. Righettoni M; Tricoli A; Pratsinis SE Anal Chem; 2010 May; 82(9):3581-7. PubMed ID: 20380475 [TBL] [Abstract][Full Text] [Related]
7. Breath Acetone Sensing Based on Single-Walled Carbon Nanotube-Titanium Dioxide Hybrids Enabled by a Custom-Built Dehumidifier. Hwang SI; Chen HY; Fenk C; Rothfuss MA; Bocan KN; Franconi NG; Morgan GJ; White DL; Burkert SC; Ellis JE; Vinay ML; Rometo DA; Finegold DN; Sejdic E; Cho SK; Star A ACS Sens; 2021 Mar; 6(3):871-880. PubMed ID: 33720705 [TBL] [Abstract][Full Text] [Related]
8. Au-modified three-dimensional In₂O₃ inverse opals: synthesis and improved performance for acetone sensing toward diagnosis of diabetes. Xing R; Li Q; Xia L; Song J; Xu L; Zhang J; Xie Y; Song H Nanoscale; 2015 Aug; 7(30):13051-60. PubMed ID: 26172336 [TBL] [Abstract][Full Text] [Related]
9. Cataluminescence sensor based on Pt/NU-901 nanocomposite for rapid capture, catalysis and detection of acetone in exhaled breath. Shi Z; Li G; Hu Y Anal Chim Acta; 2022 May; 1206():339787. PubMed ID: 35473866 [TBL] [Abstract][Full Text] [Related]
10. Colorimetric Sensor for Online Accurate Detection of Breath Acetone. Wang D; Zhang F; Prabhakar A; Qin X; Forzani ES; Tao N ACS Sens; 2021 Feb; 6(2):450-453. PubMed ID: 33210907 [TBL] [Abstract][Full Text] [Related]
12. A metal-organic framework loaded paper-based chemiluminescence sensor for trace acetone detection in exhaled breath. Lv C; Hou Y; Guo Y; Ma X; Zhang Y; Liu Y; Jin Y; Li B; Liu W Anal Methods; 2022 Nov; 14(44):4514-4522. PubMed ID: 36326109 [TBL] [Abstract][Full Text] [Related]
13. Breath acetone monitoring by portable Si:WO3 gas sensors. Righettoni M; Tricoli A; Gass S; Schmid A; Amann A; Pratsinis SE Anal Chim Acta; 2012 Aug; 738():69-75. PubMed ID: 22790702 [TBL] [Abstract][Full Text] [Related]
14. A sub-ppm acetone gas sensor for diabetes detection using 10 nm thick ultrathin InN FETs. Kao KW; Hsu MC; Chang YH; Gwo S; Yeh JA Sensors (Basel); 2012; 12(6):7157-68. PubMed ID: 22969342 [TBL] [Abstract][Full Text] [Related]
15. Selective detection of acetone and hydrogen sulfide for the diagnosis of diabetes and halitosis using SnO(2) nanofibers functionalized with reduced graphene oxide nanosheets. Choi SJ; Jang BH; Lee SJ; Min BK; Rothschild A; Kim ID ACS Appl Mater Interfaces; 2014 Feb; 6(4):2588-97. PubMed ID: 24456186 [TBL] [Abstract][Full Text] [Related]
16. Accuracy of a breath ketone analyzer to detect ketosis in adults and children with type 1 diabetes. Akturk HK; Snell-Bergeon J; Pyle L; Fivekiller E; Garg S; Cobry E J Diabetes Complications; 2021 Nov; 35(11):108030. PubMed ID: 34481712 [TBL] [Abstract][Full Text] [Related]
17. A comparison of online and offline measurement of exhaled breath for diabetes pre-screening by graphene-based sensor; from powder processing to clinical monitoring prototype. Kalidoss R; Umapathy S J Breath Res; 2019 May; 13(3):036008. PubMed ID: 30794992 [TBL] [Abstract][Full Text] [Related]
18. Superior acetone sensor based on hetero-interface of SnSe Jin S; Wu D; Song W; Hao H; Gao W; Yan S J Colloid Interface Sci; 2022 Sep; 621():119-130. PubMed ID: 35452926 [TBL] [Abstract][Full Text] [Related]
19. The correlation between breath acetone and blood betahydroxybutyrate in individuals with type 1 diabetes. Hancock G; Sharma S; Galpin M; Lunn D; Megson C; Peverall R; Richmond G; Ritchie GAD; Owen KR J Breath Res; 2020 Oct; 15(1):017101. PubMed ID: 33027776 [TBL] [Abstract][Full Text] [Related]