145 related articles for article (PubMed ID: 38160635)
1. An integrated plant glucose monitoring system based on microneedle-enabled electrochemical sensor.
Chen H; Zhou S; Chen J; Zhou J; Fan K; Pan Y; Ping J
Biosens Bioelectron; 2024 Mar; 248():115964. PubMed ID: 38160635
[TBL] [Abstract][Full Text] [Related]
2. A 3D-printed hollow microneedle-based electrochemical sensing device for in situ plant health monitoring.
Parrilla M; Sena-Torralba A; Steijlen A; Morais S; Maquieira Á; De Wael K
Biosens Bioelectron; 2024 May; 251():116131. PubMed ID: 38367566
[TBL] [Abstract][Full Text] [Related]
3. Microneedle electrochemical sensor based on disposable stainless-steel wire for real-time analysis of indole-3-acetic acid and salicylic acid in tomato leaves infected by Pst DC3000 in situ.
Tang L; Li D; Liu W; Tang Y; Zhang R; Tian Y; Tan R; Yang X; Sun L
Anal Chim Acta; 2024 Aug; 1316():342875. PubMed ID: 38969433
[TBL] [Abstract][Full Text] [Related]
4. A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid.
Yin S; Yu Z; Song N; Guo Z; Li W; Ma J; Wang X; Liu J; Liang M
Biosens Bioelectron; 2024 Jan; 244():115822. PubMed ID: 37956637
[TBL] [Abstract][Full Text] [Related]
5. Hollow microneedle-based sensor for multiplexed transdermal electrochemical sensing.
Miller PR; Skoog SA; Edwards TL; Wheeler DR; Xiao X; Brozik SM; Polsky R; Narayan RJ
J Vis Exp; 2012 Jun; (64):e4067. PubMed ID: 22688693
[TBL] [Abstract][Full Text] [Related]
6. An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids.
Yang Y; Sheng C; Dong F; Liu S
Biosens Bioelectron; 2024 Jul; 256():116280. PubMed ID: 38603840
[TBL] [Abstract][Full Text] [Related]
7. Electrochemical detection of cholesterol in human biofluid using microneedle sensor.
Li Z; Kadian S; Mishra RK; Huang T; Zhou C; Liu S; Wang Z; Narayan R; Zhu Z
J Mater Chem B; 2023 Jul; 11(26):6075-6081. PubMed ID: 37254923
[TBL] [Abstract][Full Text] [Related]
8. Impedance-based polymer microneedle patch sensor for continuous interstitial fluid glucose monitoring.
Piao H; Choi YH; Kim J; Park D; Lee J; Khang DY; Choi HJ
Biosens Bioelectron; 2024 Mar; 247():115932. PubMed ID: 38113695
[TBL] [Abstract][Full Text] [Related]
9. Fully integrated wearable microneedle biosensing platform for wide-range and real-time continuous glucose monitoring.
Li L; Zhou Y; Sun C; Zhou Z; Zhang J; Xu Y; Xiao X; Deng H; Zhong Y; Li G; Chen Z; Deng W; Hu X; Wang Y
Acta Biomater; 2024 Feb; 175():199-213. PubMed ID: 38160859
[TBL] [Abstract][Full Text] [Related]
10. Real-time intradermal continuous glucose monitoring using a minimally invasive microneedle-based system.
Ribet F; Stemme G; Roxhed N
Biomed Microdevices; 2018 Dec; 20(4):101. PubMed ID: 30523421
[TBL] [Abstract][Full Text] [Related]
11. Non-invasive in-vivo glucose-based stress monitoring in plants.
Perdomo SA; De la Paz E; Del Caño R; Seker S; Saha T; Wang J; Jaramillo-Botero A
Biosens Bioelectron; 2023 Jul; 231():115300. PubMed ID: 37058961
[TBL] [Abstract][Full Text] [Related]
12. Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays.
Mohan AMV; Windmiller JR; Mishra RK; Wang J
Biosens Bioelectron; 2017 May; 91():574-579. PubMed ID: 28088750
[TBL] [Abstract][Full Text] [Related]
13. Sensitive Electrochemical Non-Enzymatic Detection of Glucose Based on Wireless Data Transmission.
Kim YJ; Chinnadayyala SR; Le HTN; Cho S
Sensors (Basel); 2022 Apr; 22(7):. PubMed ID: 35408401
[TBL] [Abstract][Full Text] [Related]
14. Integrated hollow microneedle-optofluidic biosensor for therapeutic drug monitoring in sub-nanoliter volumes.
Ranamukhaarachchi SA; Padeste C; Dübner M; Häfeli UO; Stoeber B; Cadarso VJ
Sci Rep; 2016 Jul; 6():29075. PubMed ID: 27380889
[TBL] [Abstract][Full Text] [Related]
15. Microneedle-Based Detection of Ketone Bodies along with Glucose and Lactate: Toward Real-Time Continuous Interstitial Fluid Monitoring of Diabetic Ketosis and Ketoacidosis.
Teymourian H; Moonla C; Tehrani F; Vargas E; Aghavali R; Barfidokht A; Tangkuaram T; Mercier PP; Dassau E; Wang J
Anal Chem; 2020 Jan; 92(2):2291-2300. PubMed ID: 31874029
[TBL] [Abstract][Full Text] [Related]
16. Integrated electronic/fluidic microneedle system for glucose sensing and insulin delivery.
Huang X; Liang B; Huang S; Liu Z; Yao C; Yang J; Zheng S; Wu F; Yue W; Wang J; Chen H; Xie X
Theranostics; 2024; 14(4):1662-1682. PubMed ID: 38389830
[No Abstract] [Full Text] [Related]
17. A highly electrocatalytic, stretchable, and breathable enzyme-free electrochemical patch based on electrospun fibers decorated with platinum nano pine needles for continuous glucose sensing in neutral conditions.
Luo G; Liu J; Xie J; Jing W; Li M; Zhao L; Li Z; Yang P; Jiang Z
Dalton Trans; 2023 Sep; 52(36):12988-12998. PubMed ID: 37650562
[TBL] [Abstract][Full Text] [Related]
18. Wearable microneedle array-based sensor for transdermal monitoring of pH levels in interstitial fluid.
Dervisevic M; Dervisevic E; Esser L; Easton CD; Cadarso VJ; Voelcker NH
Biosens Bioelectron; 2023 Feb; 222():114955. PubMed ID: 36462430
[TBL] [Abstract][Full Text] [Related]
19. Fabrication of Multiple-Channel Electrochemical Microneedle Electrode Array via Separated Functionalization and Assembly Method.
Huang XS; Huang S; Zheng ST; Liang BM; Zhang T; Yue W; Liu FM; Shi P; Xie X; Chen HJ
Biosensors (Basel); 2024 May; 14(5):. PubMed ID: 38785717
[TBL] [Abstract][Full Text] [Related]
20. One-step laser synthesis platinum nanostructured 3D porous graphene: A flexible dual-functional electrochemical biosensor for glucose and pH detection in human perspiration.
Wang Y; Guo H; Yuan M; Yu J; Wang Z; Chen X
Talanta; 2023 May; 257():124362. PubMed ID: 36801557
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]