These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 38161602)
1. Positional Relationship between Two Microcatheters according to the Navigation Sequence within the Curved Vessel in Neuroendovascular Procedures. Ohshima T; Miyachi S Asian J Neurosurg; 2023 Dec; 18(4):831-835. PubMed ID: 38161602 [TBL] [Abstract][Full Text] [Related]
2. Positional Relationship between Two Microcatheters according to the Navigation Sequence within the Curved Vessel in Neuroendovascular Procedures. Ohshima T; Koiwai M; Matsuo N; Miyachi S Asian J Neurosurg; 2024 Sep; 19(3):349-353. PubMed ID: 39205890 [No Abstract] [Full Text] [Related]
3. Simple and Reproducible Microcatheter Shaping Method for Coil Embolization of Medially-directed Paraclinoid Internal Carotid Artery Aneurysms. Matsumoto H; Nishiyama H; Izawa D; Toki N J Neuroendovasc Ther; 2020; 14(4):119-125. PubMed ID: 37520175 [TBL] [Abstract][Full Text] [Related]
4. Tailor-made shaping of microcatheters using three-dimensional printed vessel models for endovascular coil embolization. Ishibashi T; Takao H; Suzuki T; Yuki I; Kaku S; Kan I; Nishimura K; Suzuki T; Watanabe M; Karagiozov K; Murayama Y Comput Biol Med; 2016 Oct; 77():59-63. PubMed ID: 27521515 [TBL] [Abstract][Full Text] [Related]
5. Local Balloon-Assisted Navigation of a Microcatheter into an Aneurysm during Intracranial Aneurysmal Coiling: A Dunk Shot Technique. Ohshima T; Kawaguchi R; Matsuo N; Miyachi S Asian J Neurosurg; 2021; 16(2):384-386. PubMed ID: 34268170 [TBL] [Abstract][Full Text] [Related]
6. Microcatheter Looping to Facilitate Aneurysm Selection in Coil Embolization of Paraclinoid Aneurysms. Cho YD; Rhim JK; Park JJ; Jeon JS; Yoo RE; Kang HS; Kim JE; Cho WS; Han MH Korean J Radiol; 2015; 16(4):899-905. PubMed ID: 26175591 [TBL] [Abstract][Full Text] [Related]
7. Balloon-assisted guide catheter positioning to overcome extreme cervical carotid tortuosity: technique and case experience. Peeling L; Fiorella D J Neurointerv Surg; 2014 Mar; 6(2):129-33. PubMed ID: 23471076 [TBL] [Abstract][Full Text] [Related]
8. Modified balloon assisted coil embolization for the treatment of intracranial and cervical arterial aneurysms using coaxial dual lumen balloon microcatheters: initial experience. Jagadeesan BD; Siddiq F; Grande AW; Tummala RP J Neurointerv Surg; 2014 Nov; 6(9):704-7. PubMed ID: 24153339 [TBL] [Abstract][Full Text] [Related]
9. Rescue embolization with direct coil delivery from dual-lumen balloon microcatheter. Chen CC; Chen CT; Hsieh PC; Yeap MC; Wu YM Interv Neuroradiol; 2022 Dec; 28(6):650-654. PubMed ID: 34806447 [TBL] [Abstract][Full Text] [Related]
10. Loop microcatheter technique for coil embolization of paraclinoid aneurysms. Jia ZY; Song YS; Sheen JJ; Kim JG; Lee CW; Suh DC Acta Neurochir (Wien); 2018 Sep; 160(9):1755-1760. PubMed ID: 30056517 [TBL] [Abstract][Full Text] [Related]
11. A novel approach involving a microcatheter tip during aneurysmal coil embolization: The Γ (gamma) tip method. Ohshima T; Miyachi S; Matsuo N; Kawaguchi R; Maejima R; Takayasu M Interv Neuroradiol; 2019 Dec; 25(6):681-684. PubMed ID: 31271078 [TBL] [Abstract][Full Text] [Related]
12. Double Microcatheter Technique Within a 5 French Guiding Catheter for Intracranial Aneurysm: Technical Notes. Ko JH; Chung J; Kim YJ World Neurosurg; 2020 Nov; 143():553-556. PubMed ID: 31954886 [TBL] [Abstract][Full Text] [Related]
13. A Novel Technique of Microcatheter Shaping using Real Image Display for Endovascular Aneurysmal Coil Embolization. Ohshima T; Nagano Y; Miyachi S Asian J Neurosurg; 2021; 16(3):645-647. PubMed ID: 34660388 [TBL] [Abstract][Full Text] [Related]
14. Microcatheter Stabilization Technique Using Partially Inflated Balloon for Coil Embolization of Paraclinoid Aneurysms. Song Y; Kwon B; Al-Abdulwahhab AH; Kurniawan RG; Suh DC Neurointervention; 2021 Jul; 16(2):132-140. PubMed ID: 34078027 [TBL] [Abstract][Full Text] [Related]
15. Use of Triple Microcatheters for Endovascular Treatment of Wide-Necked Intracranial Aneurysms: A Single Center Experience. Cho YD; Rhim JK; Kang HS; Park JJ; Jeon JP; Kim JE; Cho WS; Han MH Korean J Radiol; 2015; 16(5):1109-18. PubMed ID: 26356992 [TBL] [Abstract][Full Text] [Related]
16. Usefulness of Adjunctive Technique with a TACTICS Catheter for Coil Embolization of Cerebral Aneurysms. Takahara M; Fukuda K; Kawano D; Yoshinaga S; Fukumoto H; Horio Y; Iwaasa M; Inoue T J Neuroendovasc Ther; 2021; 15(9):589-594. PubMed ID: 37501746 [TBL] [Abstract][Full Text] [Related]
17. Dual Microcatheter Technique for Coiling of Intracranial Aneurysms: 2-Dimensional Operative Video. Waqas M; Dossani RH; Cappuzzo JM; Sonig A; Becker AB; Levy EI Oper Neurosurg (Hagerstown); 2021 May; 20(6):E428-E429. PubMed ID: 33763692 [TBL] [Abstract][Full Text] [Related]
18. <Editors' Choice> Initial experience with in vivo "endovascular shaping" technique that utilizes the vascular configuration for small cerebral aneurysm coiling. Hanaoka Y; Koyama JI; Yamazaki D; Miyaoka Y; Fujii Y; Nakamura T; Ogiwara T; Ito K; Horiuchi T Nagoya J Med Sci; 2020 May; 82(2):355-362. PubMed ID: 32581414 [TBL] [Abstract][Full Text] [Related]
19. Usefulness of modified pigtail-shaped microguidewire guidance for microcatheter navigation in difficult vasculatures during neuroendovascular interventions. Ohshima T; Shamim Ul Haq Siddiqi ; Miyachi S; Matsuo N; Kawaguchi R; Kato Y; Takayasu M Nagoya J Med Sci; 2018 Nov; 80(4):551-557. PubMed ID: 30587869 [TBL] [Abstract][Full Text] [Related]
20. Balloon-Assistance for the Transcirculation Access of a Remodeling Balloon for Coiling of Wide-Necked Aneurysms: Report of Two Cases. Balaguruswamy MM; Mohamed E; Vijayan K; Juluri CS; Madeswaran K Neurointervention; 2021 Jul; 16(2):165-170. PubMed ID: 34015885 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]