132 related articles for article (PubMed ID: 38163343)
1. IMAGINER: improving accuracy with a mixed reality navigation system during placement of external ventricular drains. A feasibility study.
Grunert R; Winkler D; Wach J; Kropla F; Scholz S; Vychopen M; Güresir E
Neurosurg Focus; 2024 Jan; 56(1):E8. PubMed ID: 38163343
[TBL] [Abstract][Full Text] [Related]
2. Accuracy of routine external ventricular drain placement following a mixed reality-guided twist-drill craniostomy.
Eom S; Ma TS; Vutakuri N; Hu T; Haskell-Mendoza AP; Sykes DAW; Gorlatova M; Jackson J
Neurosurg Focus; 2024 Jan; 56(1):E11. PubMed ID: 38163351
[TBL] [Abstract][Full Text] [Related]
3. The effect of augmented reality on the accuracy and learning curve of external ventricular drain placement.
Van Gestel F; Frantz T; Vannerom C; Verhellen A; Gallagher AG; Elprama SA; Jacobs A; Buyl R; Bruneau M; Jansen B; Vandemeulebroucke J; Scheerlinck T; Duerinck J
Neurosurg Focus; 2021 Aug; 51(2):E8. PubMed ID: 34333479
[TBL] [Abstract][Full Text] [Related]
4. A simple and cost-effective model for ventricular catheter placement training: technical note.
Todnem N; Nguyen KD; Reddy V; Grogan D; Waitt T; Alleyne CH
J Neurosurg; 2020 May; 134(5):1640-1643. PubMed ID: 32357317
[TBL] [Abstract][Full Text] [Related]
5. Orthogonal external ventricular drain (EVD) trajectory from burr holes sited by junior neurosurgical staff is superior to freehand placement: An in-silico model.
Stuart MJ; Mehigan B; Colbran RE; Withers TK; Ng W
J Clin Neurosci; 2021 Dec; 94():65-69. PubMed ID: 34863464
[TBL] [Abstract][Full Text] [Related]
6. Is Image Guidance Essential for External Ventricular Drain Insertion?
Fisher B; Soon WC; Ong J; Chan T; Chowdhury Y; Hodson J; White A
World Neurosurg; 2021 Dec; 156():e329-e337. PubMed ID: 34555577
[TBL] [Abstract][Full Text] [Related]
7. High accuracy of external ventricular drainage placement using anatomical landmarks.
Brenke C; Fürst J; Katsigiannis S; Carolus AE
Neurochirurgie; 2020 Dec; 66(6):435-441. PubMed ID: 33080249
[TBL] [Abstract][Full Text] [Related]
8. Bullseye EVD: preclinical evaluation of an intra-procedural system to confirm external ventricular drainage catheter positioning.
Hopfgartner A; Burns D; Suppiah S; Martin AR; Hardisty M; Whyne CM
Int J Comput Assist Radiol Surg; 2022 Jul; 17(7):1191-1199. PubMed ID: 35633491
[TBL] [Abstract][Full Text] [Related]
9. App-assisted external ventricular drain insertion.
Eftekhar B
J Neurosurg; 2016 Sep; 125(3):754-8. PubMed ID: 26654178
[TBL] [Abstract][Full Text] [Related]
10. A wearable mixed-reality holographic computer for guiding external ventricular drain insertion at the bedside.
Li Y; Chen X; Wang N; Zhang W; Li D; Zhang L; Qu X; Cheng W; Xu Y; Chen W; Yang Q
J Neurosurg; 2018 Oct; 131(5):1599-1606. PubMed ID: 30485188
[TBL] [Abstract][Full Text] [Related]
11. Robotic external ventricular drain placement for acute neurosurgical care in low-resource settings: feasibility considerations and a prototype design.
Smith AD; Teague AJ; Naik A; Janbahan M; Smith EJ; Krist DT; Parupalli S; Teal K; Hassaneen W
Neurosurg Focus; 2022 Jan; 52(1):E14. PubMed ID: 34973667
[TBL] [Abstract][Full Text] [Related]
12. sEVD-smartphone-navigated placement of external ventricular drains.
Eisenring CV; Burn F; Baumann M; Stieglitz LH; Kockro RA; Beck J; Raabe A; Oertel MF
Acta Neurochir (Wien); 2020 Mar; 162(3):513-521. PubMed ID: 31761975
[TBL] [Abstract][Full Text] [Related]
13. Determinants of accuracy of freehand external ventricular drain placement by neurosurgical trainees.
Pishjoo M; Khatibi K; Etemadrezaie H; Zabihyan S; Ganjeifar B; Safdari M; Baharvahdat H
Acta Neurochir (Wien); 2021 Apr; 163(4):1113-1119. PubMed ID: 33404870
[TBL] [Abstract][Full Text] [Related]
14. Accuracy of freehand external ventricular drain placement in patients after a large decompressive hemicraniectomy.
Mizrahi CJ; Paldor I; Candanedo C; Mollica S; Itshayek E
J Clin Neurosci; 2020 Nov; 81():27-31. PubMed ID: 33222928
[TBL] [Abstract][Full Text] [Related]
15. Augmented reality-assisted ventriculostomy.
Schneider M; Kunz C; Pal'a A; Wirtz CR; Mathis-Ullrich F; Hlaváč M
Neurosurg Focus; 2021 Jan; 50(1):E16. PubMed ID: 33386016
[TBL] [Abstract][Full Text] [Related]
16. External Ventricular Drainage Complication Risks and Accuracy Analysis.
Konovalov AN; Grebenev FV; Rybakov VA; Pilipenko YV; Shekhtman OD; Okishev DN; Yershova ON; Eliava SS
World Neurosurg; 2021 Dec; 156():e276-e282. PubMed ID: 34543732
[TBL] [Abstract][Full Text] [Related]
17. Guided (VENTRI-GUIDE) versus freehand ventriculostomy: study protocol for a randomized controlled trial.
Sarrafzadeh A; Smoll N; Schaller K
Trials; 2014 Dec; 15():478. PubMed ID: 25480528
[TBL] [Abstract][Full Text] [Related]
18. Improved Accuracy and Lowered Learning Curve of Ventricular Targeting Using Augmented Reality-Phantom and Cadaveric Model Testing.
Bounajem MT; Cameron B; Sorensen K; Parr R; Gibby W; Prashant G; Evans JJ; Karsy M
Neurosurgery; 2023 Apr; 92(4):884-891. PubMed ID: 36562619
[TBL] [Abstract][Full Text] [Related]
19. Accuracy of augmented reality-guided drainage versus stereotactic and conventional puncture in an intracerebral hemorrhage phantom model.
Demerath T; Stanicki A; Roelz R; Farina Nunez MT; Bissolo M; Steiert C; Fistouris P; Coenen VA; Urbach H; Fung C; Beck J; Reinacher PC
J Neurointerv Surg; 2023 Jul; 15(7):708-711. PubMed ID: 35853700
[TBL] [Abstract][Full Text] [Related]
20. Integrated flat detector CT and live fluoroscopic-guided external ventricular drain placement within the neuroangiography suite.
Fiorella D; Peeling L; Denice CM; Sarmiento M; Woo HH
J Neurointerv Surg; 2014 Jul; 6(6):457-60. PubMed ID: 23892444
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]