188 related articles for article (PubMed ID: 38168438)
1. Terahertz polarimetric imaging of biological tissues: Monte Carlo modeling of signal contrast mechanisms due to Mie scattering.
Xu K; Arbab MH
Res Sq; 2023 Dec; ():. PubMed ID: 38168438
[TBL] [Abstract][Full Text] [Related]
2. Terahertz polarimetric imaging of biological tissue: Monte Carlo modeling of signal contrast mechanisms due to Mie scattering.
Xu K; Arbab MH
Biomed Opt Express; 2024 Apr; 15(4):2328-2342. PubMed ID: 38633080
[TBL] [Abstract][Full Text] [Related]
3. Ultrahigh polarimetric image contrast enhancement for skin cancer diagnosis using InN plasmonic nanoparticles in the terahertz range.
Ney M; Abdulhalim I
J Biomed Opt; 2015; 20(12):125007. PubMed ID: 26720872
[TBL] [Abstract][Full Text] [Related]
4. Polarimetric imaging of back-scattered terahertz speckle fields using a portable scanner.
Xu K; Harris ZB; Arbab MH
Opt Express; 2023 Mar; 31(7):11308-11319. PubMed ID: 37155769
[TBL] [Abstract][Full Text] [Related]
5. Mueller matrix imaging of human colon tissue for cancer diagnostics: how Monte Carlo modeling can help in the interpretation of experimental data.
Antonelli MR; Pierangelo A; Novikova T; Validire P; Benali A; Gayet B; De Martino A
Opt Express; 2010 May; 18(10):10200-8. PubMed ID: 20588874
[TBL] [Abstract][Full Text] [Related]
6. Impact of model parameters on Monte Carlo simulations of backscattering Mueller matrix images of colon tissue.
Antonelli MR; Pierangelo A; Novikova T; Validire P; Benali A; Gayet B; De Martino A
Biomed Opt Express; 2011 Jul; 2(7):1836-51. PubMed ID: 21750762
[TBL] [Abstract][Full Text] [Related]
7. Analysis of tissue microstructure with Mueller microscopy: logarithmic decomposition and Monte Carlo modeling.
Li P; Lee HR; Chandel S; Lotz C; Groeber-Becker FK; Dembski S; Ossikovski R; Ma H; Novikova T
J Biomed Opt; 2020 Jan; 25(1):1-11. PubMed ID: 31933331
[No Abstract] [Full Text] [Related]
8. All-dielectric polarization-sensitive metasurface for terahertz polarimetric imaging.
Baek J; Kim J; Seol JH; Kim M
Sci Rep; 2024 Mar; 14(1):7544. PubMed ID: 38555396
[TBL] [Abstract][Full Text] [Related]
9. Modelling the propagation of terahertz radiation through a tissue simulating phantom.
Walker GC; Berry E; Smye SW; Zinov'ev NN; Fitzgerald AJ; Miles RE; Chamberlain M; Smith MA
Phys Med Biol; 2004 May; 49(10):1853-64. PubMed ID: 15214528
[TBL] [Abstract][Full Text] [Related]
10. Mueller polarimetric imaging for surgical and diagnostic applications: a review.
Qi J; Elson DS
J Biophotonics; 2017 Aug; 10(8):950-982. PubMed ID: 28464464
[TBL] [Abstract][Full Text] [Related]
11. Polarimetric infrared imaging simulation of a synthetic sea surface with Mie scattering.
He S; Wang X; Xia R; Jin W; Liang J
Appl Opt; 2018 Mar; 57(7):B150-B159. PubMed ID: 29522035
[TBL] [Abstract][Full Text] [Related]
12. Advances in terahertz technology for cancer detection applications.
Gezimati M; Singh G
Opt Quantum Electron; 2023; 55(2):151. PubMed ID: 36588663
[TBL] [Abstract][Full Text] [Related]
13. Metamaterials for THz polarimetric devices.
Peralta XG; Smirnova EI; Azad AK; Chen HT; Taylor AJ; Brener I; O'Hara JF
Opt Express; 2009 Jan; 17(2):773-83. PubMed ID: 19158890
[TBL] [Abstract][Full Text] [Related]
14. Do different turbid media with matched bulk optical properties also exhibit similar polarization properties?
Ahmad M; Alali S; Kim A; Wood MF; Ikram M; Vitkin IA
Biomed Opt Express; 2011 Dec; 2(12):3248-58. PubMed ID: 22162815
[TBL] [Abstract][Full Text] [Related]
15. Continuous-wave circular polarization terahertz imaging.
Martin JP; Joseph CS; Giles RH
J Biomed Opt; 2016 Jul; 21(7):70502. PubMed ID: 27420650
[TBL] [Abstract][Full Text] [Related]
16. Comparative study of the imaging contrasts of Mueller matrix derived parameters between transmission and backscattering polarimetry.
Liu T; Sun T; He H; Liu S; Dong Y; Wu J; Ma H
Biomed Opt Express; 2018 Sep; 9(9):4413-4428. PubMed ID: 30615708
[TBL] [Abstract][Full Text] [Related]
17. Heterostructure terahertz devices.
Ryzhii V
J Phys Condens Matter; 2008 Aug; 20(38):380301. PubMed ID: 21693805
[TBL] [Abstract][Full Text] [Related]
18. Morphology of human sweat ducts observed by optical coherence tomography and their frequency of resonance in the terahertz frequency region.
Tripathi SR; Miyata E; Ishai PB; Kawase K
Sci Rep; 2015 Mar; 5():9071. PubMed ID: 25766116
[TBL] [Abstract][Full Text] [Related]
19. Mueller matrix decomposition for extraction of individual polarization parameters from complex turbid media exhibiting multiple scattering, optical activity, and linear birefringence.
Ghosh N; Wood MF; Vitkin IA
J Biomed Opt; 2008; 13(4):044036. PubMed ID: 19021363
[TBL] [Abstract][Full Text] [Related]
20. Spatial analysis of polarimetric images to enhance near-surface sampling sensitivity: feasibility in demineralized teeth and other tissue-like media.
Singh MD; Lilge L; Vitkin A
J Biomed Opt; 2023 Oct; 28(10):102906. PubMed ID: 37692083
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]