  • 21. Monte Carlo simulation of PET and SPECT imaging of 90Y.
    Takahashi A; Himuro K; Yamashita Y; Komiya I; Baba S; Sasaki M
    Med Phys; 2015 Apr; 42(4):1926-35. PubMed ID: 25832083
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A tissue-fraction estimation-based segmentation method for quantitative dopamine transporter SPECT.
    Liu Z; Moon HS; Li Z; Laforest R; Perlmutter JS; Norris SA; Jha AK
    Med Phys; 2022 Aug; 49(8):5121-5137. PubMed ID: 35635327
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of 3D Monte Carlo-based scatter correction for 201Tl cardiac perfusion SPECT.
    Xiao J; de Wit TC; Zbijewski W; Staelens SG; Beekman FJ
    J Nucl Med; 2007 Apr; 48(4):637-44. PubMed ID: 17401103
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Computer-assisted delineation of hematoma from CT volume using autoencoder and Chan Vese model.
    Nag MK; Chatterjee S; Sadhu AK; Chatterjee J; Ghosh N
    Int J Comput Assist Radiol Surg; 2019 Feb; 14(2):259-269. PubMed ID: 30377937
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Simultaneous 99mTc-MDP/123I-MIBG tumor imaging using SPECT-CT: phantom and constructed patient studies.
    Rakvongthai Y; El Fakhri G; Lim R; Bonab AA; Ouyang J
    Med Phys; 2013 Oct; 40(10):102506. PubMed ID: 24089927
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Automatic multi-organ segmentation from abdominal CT volumes with LLE-based graph partitioning and 3D Chan-Vese model.
    Tang P; Zhao YQ; Liao M
    Comput Biol Med; 2021 Dec; 139():105030. PubMed ID: 34800809
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effects of shortened acquisition time on accuracy and precision of quantitative estimates of organ activity.
    He B; Frey EC
    Med Phys; 2010 Apr; 37(4):1807-15. PubMed ID: 20443503
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Development and evaluation of convergent and accelerated penalized SPECT image reconstruction methods for improved dose-volume histogram estimation in radiopharmaceutical therapy.
    Cheng L; Hobbs RF; Sgouros G; Frey EC
    Med Phys; 2014 Nov; 41(11):112507. PubMed ID: 25370666
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A method of rapid quantification of patient-specific organ doses for CT using deep-learning-based multi-organ segmentation and GPU-accelerated Monte Carlo dose computing.
    Peng Z; Fang X; Yan P; Shan H; Liu T; Pei X; Wang G; Liu B; Kalra MK; Xu XG
    Med Phys; 2020 Jun; 47(6):2526-2536. PubMed ID: 32155670
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Impact of missing attenuation and scatter corrections on
    Botta F; Ferrari M; Chiesa C; Vitali S; Guerriero F; Nile MC; Mira M; Lorenzon L; Pacilio M; Cremonesi M
    Med Phys; 2018 Apr; 45(4):1684-1698. PubMed ID: 29383733
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Automatic attenuation map estimation from SPECT data only for brain perfusion scans using convolutional neural networks.
    Chen Y; Goorden MC; Beekman FJ
    Phys Med Biol; 2021 Mar; 66(6):065006. PubMed ID: 33571975
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT.
    Xiao J; de Wit TC; Staelens SG; Beekman FJ
    J Nucl Med; 2006 Oct; 47(10):1662-9. PubMed ID: 17015903
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Quantitative Monte Carlo-based brain dopamine transporter SPECT imaging.
    Kangasmaa T; Hippeläinen E; Constable C; Turunen S; Sohlberg A
    Ann Nucl Med; 2021 Jan; 35(1):17-23. PubMed ID: 32978713
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Folic acid supplementation and malaria susceptibility and severity among people taking antifolate antimalarial drugs in endemic areas.
    Crider K; Williams J; Qi YP; Gutman J; Yeung L; Mai C; Finkelstain J; Mehta S; Pons-Duran C; Menéndez C; Moraleda C; Rogers L; Daniels K; Green P
    Cochrane Database Syst Rev; 2022 Feb; 2(2022):. PubMed ID: 36321557
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fast GPU-based Monte Carlo code for SPECT/CT reconstructions generates improved
    Rydén T; Heydorn Lagerlöf J; Hemmingsson J; Marin I; Svensson J; Båth M; Gjertsson P; Bernhardt P
    EJNMMI Phys; 2018 Jan; 5(1):1. PubMed ID: 29302810
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition.
    Huh Y; Shrestha UM; Gullberg GT; Seo Y
    Front Cardiovasc Med; 2022; 9():871967. PubMed ID: 35911544
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Use of the FLUKA Monte Carlo code for 3D patient-specific dosimetry on PET-CT and SPECT-CT images.
    Botta F; Mairani A; Hobbs RF; Vergara Gil A; Pacilio M; Parodi K; Cremonesi M; Coca Pérez MA; Di Dia A; Ferrari M; Guerriero F; Battistoni G; Pedroli G; Paganelli G; Torres Aroche LA; Sgouros G
    Phys Med Biol; 2013 Nov; 58(22):8099-120. PubMed ID: 24200697
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm.
    Li S; Zhang J; Krol A; Schmidtlein CR; Vogelsang L; Shen L; Lipson E; Feiglin D; Xu Y
    Med Phys; 2015 Aug; 42(8):4872-87. PubMed ID: 26233214
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of reconstruction techniques for lung single photon emission tomography: a Monte Carlo study.
    Norberg P; Bake B; Jacobsson L; Carlsson GA; Gustafsson A
    Nucl Med Commun; 2007 Dec; 28(12):929-36. PubMed ID: 18090220
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method.
    Rong X; Du Y; Ljungberg M; Rault E; Vandenberghe S; Frey EC
    Med Phys; 2012 May; 39(5):2346-58. PubMed ID: 22559605
    [TBL] [Abstract][Full Text] [Related]  