123 related articles for article (PubMed ID: 38191542)
1. Comparison of Different Fixation Confi gurations in Different Types of High Pediatric Supracondylar Humerus Fractures: a Finite Element Analysis.
Bozoğlan M; Kumbaraci M; Özer A; Turgut A
Acta Chir Orthop Traumatol Cech; 2023; 90(6):408-415. PubMed ID: 38191542
[TBL] [Abstract][Full Text] [Related]
2. Mechanical stability study of three techniques used in the fixation of transverse and oblique metaphyseal-diaphyseal junction fractures of the distal humerus in children: a finite element analysis.
Liu C; Kamara A; Liu T; Yan Y; Wang E
J Orthop Surg Res; 2020 Jan; 15(1):34. PubMed ID: 32020882
[TBL] [Abstract][Full Text] [Related]
3. The most stable pinning configurations in transverse supracondylar humerus fracture fixation in children: A novel three-dimensional finite element analysis of a pediatric bone model.
Kamara A; Ji X; Liu C; Liu T; Wang E
Injury; 2021 Jun; 52(6):1310-1315. PubMed ID: 33516568
[TBL] [Abstract][Full Text] [Related]
4. Biomechanical analysis between Orthofix® external fixator and different K-wire configurations for pediatric supracondylar humerus fractures.
Li WC; Meng QX; Xu RJ; Cai G; Chen H; Li HJ
J Orthop Surg Res; 2018 Jul; 13(1):188. PubMed ID: 30055630
[TBL] [Abstract][Full Text] [Related]
5. A comparative biomechanical study on different fixation techniques in the management of transverse metaphyseal-diaphyseal junction fractures of the distal humerus in children.
Kamara A; Ji X; Liu T; Zhan Y; Li J; Wang E
Int Orthop; 2019 Feb; 43(2):411-416. PubMed ID: 29744649
[TBL] [Abstract][Full Text] [Related]
6. [Three-dimensional finite element analysis of Kirschner wire fixation configuration for supracondylar fracture of humerus fracture in children].
Liu XF; Allieu K; Liu C; Wang EB; Ji XL; Liu TJ; Li QL
Zhongguo Gu Shang; 2020 Oct; 33(10):948-53. PubMed ID: 33107259
[TBL] [Abstract][Full Text] [Related]
7. The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis.
Durusoy S; Öner K; Özer A; Sevinç HF
Jt Dis Relat Surg; 2021; 32(1):75-84. PubMed ID: 33463421
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical analysis of supracondylar humerus fracture pinning for fractures with coronal lateral obliquity.
Feng C; Guo Y; Zhu Z; Zhang J; Wang Y
J Pediatr Orthop; 2012 Mar; 32(2):196-200. PubMed ID: 22327455
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical analysis of pinning configurations for a supracondylar humerus fracture with coronal medial obliquity.
Wang X; Feng C; Wan S; Bian Z; Zhang J; Song M; Shao J; Yang X
J Pediatr Orthop B; 2012 Nov; 21(6):495-8. PubMed ID: 22735920
[TBL] [Abstract][Full Text] [Related]
10. Burnei's "double X" internal fixation technique for supracondylar humerus fractures in children: indications, technique, advantages and alternative interventions : Study and Research Group in Pediatric Orthopaedics-2012.
Georgescu I; Gavriliu S; Pârvan A; Martiniuc A; Japie E; Ghiță R; Drăghici I; Hamei Ş; Ţiripa I; El Nayef T; Dan D
J Med Life; 2013 Jun; 6(2):131-9. PubMed ID: 23904871
[TBL] [Abstract][Full Text] [Related]
11. Fractures of the distal humeral metaphyseal-diaphyseal junction in children.
Fayssoux RS; Stankovits L; Domzalski ME; Guille JT
J Pediatr Orthop; 2008 Mar; 28(2):142-6. PubMed ID: 18388705
[TBL] [Abstract][Full Text] [Related]
12. Biomechanical Analysis of Two Types of Humerus Supracondylar Fracture Fixation in Anatomical Model.
Nunes MC; Posser TD; Israel CL; Spinelli LF; Calieron LG; Kim JH
Rev Bras Ortop (Sao Paulo); 2019 May; 54(3):261-267. PubMed ID: 31363279
[No Abstract] [Full Text] [Related]
13. Biomechanical analysis of supracondylar humerus fracture pinning for slightly malreduced fractures.
Bloom T; Robertson C; Mahar AT; Newton P
J Pediatr Orthop; 2008; 28(7):766-72. PubMed ID: 18812905
[TBL] [Abstract][Full Text] [Related]
14. Finite element analysis of modified Slongo's external fixation in the treatment of supracondylar humeral fractures in older children.
Zhao J; Yao W; Ma J; Lu B; Ma X
Medicine (Baltimore); 2024 May; 103(18):e37979. PubMed ID: 38701293
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical analysis of pinning techniques for pediatric supracondylar humerus fractures.
Larson L; Firoozbakhsh K; Passarelli R; Bosch P
J Pediatr Orthop; 2006; 26(5):573-8. PubMed ID: 16932093
[TBL] [Abstract][Full Text] [Related]
16. Finite element analyses of lateral condyle fracture fixation in paediatrics regarding configuration of Kirschner-wire.
Jeon S; Ahn W; Oh J; Chung J; Choi J; Lee S
BMC Musculoskelet Disord; 2022 Oct; 23(1):940. PubMed ID: 36307784
[TBL] [Abstract][Full Text] [Related]
17. [Lateral mini plate and Kirschner wire assisted fixation for the treatment of distal humeral metaphyseal junction fracture in children].
Xue YL; Chen YG; Bian XJ; Zhang B
Zhongguo Gu Shang; 2020 Apr; 33(4):379-82. PubMed ID: 32351096
[TBL] [Abstract][Full Text] [Related]
18. Biomechanical analysis of lateral pin placements for pediatric supracondylar humerus fractures.
Hamdi A; Poitras P; Louati H; Dagenais S; Masquijo JJ; Kontio K
J Pediatr Orthop; 2010 Mar; 30(2):135-9. PubMed ID: 20179560
[TBL] [Abstract][Full Text] [Related]
19. Assessment of Lateral Rotation Percentage and Rotational Deformity of the Elbow in Type 3 Supracondylar Humerus Fractures: A Biomechanical Study.
Berdis G; Hooper M; Talwalkar V; Walker J; Muchow R; Riley S; Iwinski HJ; Prusick V
J Pediatr Orthop; 2021 Sep; 41(8):e605-e609. PubMed ID: 34091555
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical comparison of different external fixator configurations for stabilization of supracondylar humerus fractures in children.
Hohloch L; Konstantinidis L; Wagner FC; Strohm PC; Südkamp NP; Reising K
Clin Biomech (Bristol, Avon); 2016 Feb; 32():118-23. PubMed ID: 26743869
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]