BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 38192687)

  • 1. Initial clinical experience with the novel POLARx FIT cryoballoon system for pulmonary vein isolation in patients with atrial fibrillation.
    Fukunaga H; Sekiguchi Y; Sawaguchi J; Hayashi Y; Asano S; Mabuchi K; Inoue K; Tanizaki K; Umemura J; Isobe M; Nitta J
    Int J Cardiol Heart Vasc; 2024 Feb; 50():101326. PubMed ID: 38192687
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Novel or established cryoballoon ablation system for pulmonary vein isolation: the prospective ICE-AGE-1 study.
    Heeger CH; Popescu SS; Inderhees T; Nussbickel N; Eitel C; Kirstein B; Phan HL; Hatahet S; Subin B; Traub A; Große N; Kuck KH; Vogler J; Tilz RR
    Europace; 2023 Aug; 25(9):. PubMed ID: 37589146
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The established and the challenger: A direct comparison of current cryoballoon technologies for pulmonary vein isolation.
    Moser F; Rottner L; Moser J; Schleberger R; Lemoine M; Münkler P; Dinshaw L; Kirchhof P; Reissmann B; Ouyang F; Rillig A; Metzner A
    J Cardiovasc Electrophysiol; 2022 Jan; 33(1):48-54. PubMed ID: 34766404
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Novel Cryoballoon Ablation System for Single Shot Pulmonary Vein Isolation - The Prospective ICE-AGE-X Study.
    Tilz RR; Meyer-Saraei R; Eitel C; Fink T; Sciacca V; Lopez LD; Kirstein B; Schlüter M; Vogler J; Kuck KH; Heeger CH
    Circ J; 2021 Jul; 85(8):1296-1304. PubMed ID: 33854004
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Atrial fibrillation cryoablation is an effective day case treatment: the UK PolarX vs. Arctic Front Advance experience.
    Honarbakhsh S; Martin CA; Mesquita J; Herlekar R; Till R; Srinivasan NT; Duncan E; Leong F; Dulai R; Veasey R; Panikker S; Paisey J; Ramgopal B; Das M; Ahmed W; Sahu J; Earley MJ; Finlay MC; Schilling RJ; Hunter RJ
    Europace; 2023 Nov; 25(11):. PubMed ID: 37738643
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of procedural efficacy and biophysical parameters between two competing cryoballoon technologies for pulmonary vein isolation: Insights from an initial multicenter experience.
    Yap SC; Anic A; Breskovic T; Haas A; Bhagwandien RE; Jurisic Z; Szili-Torok T; Luik A
    J Cardiovasc Electrophysiol; 2021 Mar; 32(3):580-587. PubMed ID: 33492749
    [TBL] [Abstract][Full Text] [Related]  

  • 7. PolarX Cryoballoon metrics predicting successful pulmonary vein isolation: targets for ablation of atrial fibrillation.
    Honarbakhsh S; Earley MJ; Martin CA; Creta A; Sohaib A; Ang R; Butcher C; Waddingham PH; Dhinoja M; Lim W; Srinivasan NT; Providencia R; Kanthasamy V; Sporton S; Chow A; Lambiase PD; Schilling RJ; Finlay MC; Hunter RJ
    Europace; 2022 Oct; 24(9):1420-1429. PubMed ID: 35737685
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of procedural efficacy, balloon nadir temperature, and incidence of phrenic nerve palsy between two cryoballoon technologies for pulmonary vein isolation: A systematic review and meta-analysis.
    Assaf A; Bhagwandien R; Szili-Torok T; Yap SC
    J Cardiovasc Electrophysiol; 2021 Sep; 32(9):2424-2431. PubMed ID: 34289198
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Key characteristics for effective acute pulmonary vein isolation when using a novel cryoballoon technology: insights from the CHARISMA registry.
    Iacopino S; Stabile G; Fassini G; De Simone A; Petretta A; Moltrasio M; La Rocca V; Placentino F; Riva S; Pesce F; Rossi P; Pelargonio G; Iuliano A; Tundo F; Colella J; Tondo C
    J Interv Card Electrophysiol; 2022 Sep; 64(3):641-648. PubMed ID: 34853986
    [TBL] [Abstract][Full Text] [Related]  

  • 10. News from the Cold Chamber: Clinical Experiences of POLARx versus Arctic Front Advance for Single-Shot Pulmonary Vein Isolation.
    Guckel D; Lucas P; Isgandarova K; El Hamriti M; Bergau L; Fink T; Sciacca V; Imnadze G; Braun M; Khalaph M; Nölker G; Sommer P; Sohns C
    J Cardiovasc Dev Dis; 2022 Jan; 9(1):. PubMed ID: 35050226
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of Arctic Front Advance Pro and POLARx cryoballoons for ablation therapy of atrial fibrillation: an intraprocedural analysis.
    Knappe V; Lahrmann C; Funken M; Zietzer A; Gestrich C; Nickenig G; Schrickel JW; Beiert T
    Clin Res Cardiol; 2024 Feb; ():. PubMed ID: 38358420
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the acute outcome of two cryoballoon technologies for pulmonary vein isolation: An updated systematic review and meta-analysis.
    Assaf A; Bhagwandien RE; Szili-Torok T; Yap SC
    Int J Cardiol Heart Vasc; 2022 Oct; 42():101115. PubMed ID: 36097550
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Outcomes after cryoballoon ablation of paroxysmal atrial fibrillation with the PolarX or the Arctic Front Advance Pro: a prospective multicentre experience.
    Tanese N; Almorad A; Pannone L; Defaye P; Jacob S; Kilani MB; Chierchia G; Venier S; Cardin C; Jacon P; Combes S; Deschamps E; Menè R; de Asmundis C; Boveda S
    Europace; 2023 Mar; 25(3):873-879. PubMed ID: 36695332
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of pulmonary vein variant anatomy and cross-sectional orifice area on freedom from atrial fibrillation recurrence after cryothermal single-shot guided pulmonary vein isolation.
    Guckel D; Lucas P; Isgandarova K; Hamriti ME; Bergau L; Fink T; Sciacca V; Braun M; Khalaph M; Imnadze G; Nölker G; Sommer P; Sohns C
    J Interv Card Electrophysiol; 2022 Oct; 65(1):251-260. PubMed ID: 35764853
    [TBL] [Abstract][Full Text] [Related]  

  • 15. PolarX vs Arctic Front for Cryoballoon Ablation of Paroxysmal AF: The Randomized COMPARE CRYO Study.
    Reichlin T; Kueffer T; Knecht S; Madaffari A; Badertscher P; Maurhofer J; Krisai P; Jufer C; Asatryan B; Heg D; Servatius H; Tanner H; Kühne M; Roten L; Sticherling C
    JACC Clin Electrophysiol; 2024 Apr; ():. PubMed ID: 38752963
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pulmonary vein isolation by means of a novel cryoballoon technology in paroxysmal atrial fibrillation patients: 1-year outcome from a large Italian multicenter clinical registry.
    Bianchi S; De Simone A; Iacopino S; Fassini G; Malacrida M; Rossi P; Stabile G; Petretta A; Tundo F; Cauti FM; Iuliano S; Filannino P; Moltrasio M; Morlacchi Bonfanti M; Pelargonio G; Pecora D; Ferraro A; Tondo C
    Pacing Clin Electrophysiol; 2023 Nov; 46(11):1302-1309. PubMed ID: 37846769
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Novel cryoballoon ablation system for pulmonary vein isolation: multicenter assessment of efficacy and safety-ANTARCTICA study.
    Heeger CH; Pott A; Sohns C; Riesinger L; Sommer P; Gasperetti A; Tondo C; Fassini G; Moser F; Lucas P; Weinmann K; Bohnen JE; Dahme T; Rillig A; Kuck KH; Wakili R; Metzner A; Tilz RR
    Europace; 2022 Dec; 24(12):1917-1925. PubMed ID: 36026521
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acute procedural efficacy and safety of a novel cryoballoon for the treatment of paroxysmal atrial fibrillation: Results from the POLAR ICE study.
    Martin CA; Tilz RRR; Anic A; Defaye P; Luik A; de Asmundis C; Champ-Rigot L; Iacopino S; Sommer P; Albrecht EM; Raybuck JD; Richards E; Cielen N; Yap SC;
    J Cardiovasc Electrophysiol; 2023 Apr; 34(4):833-840. PubMed ID: 36786515
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Procedural performance between two cryoballoon systems for ablation of atrial fibrillation depends on pulmonary vein anatomy.
    Menger V; Frick M; Sharif-Yakan A; Emrani M; Zink MD; Napp A; Marx N; Gramlich M
    J Arrhythm; 2023 Jun; 39(3):341-351. PubMed ID: 37324756
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation.
    Aryana A; Mugnai G; Singh SM; Pujara DK; de Asmundis C; Singh SK; Bowers MR; Brugada P; d'Avila A; O'Neill PG; Chierchia GB
    Heart Rhythm; 2016 Feb; 13(2):424-32. PubMed ID: 26520204
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.